Report No.:  EM201200813-6                Application No.:  ZJ00024740                        Page 21 of 61 
 
 
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBuV/m) 
Factor(dB/m)
(dBuV/m) 
(dBuV/m) 
(dB) 
 
1 2685.226 30.68  19.32  50.00  70.00 -20.00 
peak 
2 2685.226 16.28  19.32  35.60  50.00 -14.40 
AVG 
3 4107.167 29.58  25.82  55.40  74.00 -18.60 
peak 
4 4107.167 17.68  25.82  43.50  54.00 -10.50 
AVG 
 
Report No.:  EM201200813-6                Application No.:  ZJ00024740                        Page 22 of 61 
 
 
Project No.: 
ZJ00022653 
Polarziation: 
Vertical 
Standard: 
(RE)EN55022_class B_3m 
Power Source: 
AC 230V/50Hz 
Test item: 
Radiation Test 
Date: 
2013-1-11 
Temp./Hum.(%RH): 23/55%RH 
Time: 
8:48:21 
EUT: JBL 
PlayUp 
Distance: 
3m 
Model: 
JBL ONBEAT RUMBLE 
Test Result: 
Pass 
Note:  
iPhone 5 (Loading and headset) 
 
 
 
 
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBuV/m) 
Factor(dB/m)
(dBuV/m) 
(dBuV/m) 
(dB) 
 
1 33.1933 14.41  17.49  31.90 40.00 -8.10 
QP 
2 43.7154 22.08  12.02  34.10 40.00 -5.90 
QP 
3 148.8219 26.88  10.02  36.90  40.00  -3.10 
QP 
4 161.9103 26.15  10.65  36.80  40.00  -3.20 
QP 
5 172.2344 26.17  10.63  36.80  40.00  -3.20 
QP 
6 184.2495 24.16  11.24  35.40  40.00  -4.60 
QP 
 
Report No.:  EM201200813-6                Application No.:  ZJ00024740                        Page 23 of 61 
 
 
 
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBuV/m) 
Factor(dB/m)
(dBuV/m) 
(dBuV/m) 
(dB) 
 
1 2015.009 30.46  14.14  44.60  70.00 -25.40  peak 
2 2015.009 16.36  14.14  30.50  50.00 -19.50  AVG 
3 3811.706 31.10  25.00  56.10  74.00 -17.90  peak 
4 3811.706 19.50  25.00  44.50  54.00  -9.50  AVG 
 
Note: This device was tested in the BT, BT(Loading), BT (Headset),BT(Headset and Loading), Audio in, 
Audio in (Loading), Audio in (Headset), Audio in (Headset and Loading), iPhone5, iPhone5 (Loading), 
iPhone5 (Headset), iPhone5 (Headset and Loading), we found the worst rad
iation emission and 
record it. 
Report No.:  EM201200813-6                Application No.:  ZJ00024740                        Page 24 of 61 
 
 
4.2 CONDUCTED EMISSION MEASUREMENT 
4.2.1 LIMITS 
AC Power port 
Frequency (MHz) 
Quasi-peakdBµV) 
AveragedBµV 
0.15 ~ 0.5 
66~56 56~46 
0.5 ~ 5 
56 46 
5 ~ 30 
60 
50 
NOTE
(1) The lower limit shall apply at the transition frequencies. 
(2) The limit decreases in line with the logarithm of the frequency in the range of  0.15 ~0.5 MHz. 
Telecommunication ports 
Frequency (MHz) 
Quasi-peakdBµV) 
AveragedBµV 
0.15 ~ 0.5 
84~74 74~64 
0.5 ~ 30 
74 64 
NOTE
(1) The lower limit shall apply at the transition frequencies. 
(2) The limit decreases in line with the logarithm of the frequency in the range of  0.15 ~0.5 MHz. 
Telecommunication ports 
4.2.2 TEST PROCEDURES 
Procedure of Preliminary Test 
For measurement of the disturbance voltage the equipment under test (EUT) is connected to 
the power supply mains and any other extended network via one or more artificial network(s). 
An EUT, whether intended to be grounded or not, and which is to be used on a table is 
configured as follows: 
–   Either the bottom or the rear of the EUT shall be at a controlled distance of 40 cm from a 
reference ground plane. This ground plane is normally the wall or floor of a shielded room. It 
may also be a grounded metal plane of at least 2 m by 2 m. This is physically accomplished as 
follows: 
1)  place the EUT on a table of non-conducting material which is at least 80 cm high. Place the 
EUT so that it is 40 cm from the wall of the shielded room, or 
2)  place the EUT on a table of non-conducting material which is 40 cm high so that the 
bottom of the EUT is 40 cm above the ground plane; 
–    All other conductive surfaces of the EUT shall be at least 80 cm from the reference ground 
plane; 
–    The ANs are placed on the floor that one side of the AN housings is 40 cm from the 
vertical reference ground plane and other metallic parts; 
–    Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded 
back and forth forming a bundle 30 cm to 40 cm long, hanging approximately in the middle 
between the ground plane and the table. 
–    I/O cables that are connected to a peripheral shall be bundled in the centre. The end of the 
cable may be terminated if required using correct terminating impedance. The total length 
shall not exceed 1 m. 
The test mode(s) described in Item 2.4 were scanned during the preliminary test. After the 
preliminary scan, we found the test mode described in Item 2.4 producing the highest 
emission level. The EUT configuration and cable configuration of the above highest emission 
Page of 61
Display

Click on the first or last page to see other ON BEAT RUMBLE (serv.man2) service manuals if exist.