EMC - CB Certificate
Brand
Device
Audio
File
on-beat-rumble-sm2.pdf
Date

JBL ON BEAT RUMBLE (serv.man2) EMC - CB Certificate ▷ View online

Report No.:  EM201200813-6                Application No.:  ZJ00024740                        Page 9 of 61 
 
 
CS 
Signal generator 
ROHDE & 
SCHWARZ 
SML03 103002 
2013-11-13 
Power meter 
BOOTON 
4232A 
10543 
2013-09-26 
Amplifier 
PRANA R&D 
AP32 DT214 
0611-768 
2013-01-03 
CDN 
EMC PARTNER
L-801 M2/M3
2265 
2013-03-09 
Injection Clamp 
PRANA R&D 
IP-DR250 
0603-0729 
2013-06-26 
VOLTAGE DIP & VOLTAGE INTERRUPTIONS 
Main Interference 
Simulator 
EMC PARTNER
TRA2000 
851 
2013-05-30 
 
3.5 MONITORING OF EUT FOR THE IMMUNITY TEST 
Visual: 
Monitored the Spectrum Analyser for any unintentional responses and any external 
change by the eyes. 
Audio: 
Hear the sound from EUT by ear. 
Monitor the SINAD by the Audio Analyser for the audio signal performance. 
 
Report No.:  EM201200813-6                Application No.:  ZJ00024740                        Page 10 of 61 
 
4. EMISSION TEST  
4.1RADIATED EMISSION MEASUREMENT 
4.1.1 LIMITS  
Frequency (MHz) 
Quasi-peak(dBµV/m) 
30~230 
40 
230~1000 
47 
NOTE: (1) The lower limit shall apply at the transition frequencies. 
FREQUENCY(MHz) 
Limits dB(
µV/m) 
Distance: 3m 
1000≤F≤3000 
70 peak 
50 Average 
3000≤F≤6000 
74 peak 
54 Average 
NOTE: The lower limit shall apply at the transition frequencies. 
4.1.2 TEST PROCEDURE 
Procedure of Preliminary Test 
Radiated emission tests shall be made with the receive or transmit antenna located at a 
horizontal distance of 3 m plus half of the maximum width of the EUT being tested, measured 
from the centre of the EUT. The tests shall be performed with the equipment configured as 
closely as possible to its typical, practical operation. Unless stated otherwise, cables and 
wiring shall be as specified by the manufacturer and the equipment shall be in its housing (or 
cabinet) with all covers and access panels in place. Any deviation from normal EUT 
operating conditions shall be included in the test report. 
The EUT (on a non-conductive support structure, where applicable) shall be placed on a 
remotely operated turntable, to allow the EUT to be rotated. The height of the EUT above the 
ground plane shall be according to the following requirements. 
• Table-top equipment is placed on a non-conductive set-up table with height 0,8 m ± 0,01 m, 
CISPR 16-1-4 specifies the method to determine the impact of the non-conductive set-up 
table on test results. 
• Floor-standing equipment is placed on a non-conductive support, as specified in the 
applicable product standard. If there are no EUT height placement requirements in the 
product standard, the EUT shall be placed on a non-conductive support at a height of 5 cm to 
15 cm above the ground plane. 
Interface cables, loads, and devices should be connected to at least one of each type of the 
interface ports of the EUT and, where practical, each cable shall be terminated in a device 
typical for its actual use. Where there are multiple interface ports of the same type, a typical 
number of these devices shall be connected to devices or loads. It is sufficient to connect only 
one of the loads, provided that it can be shown, for example by preliminary testing, that the 
connection of further ports would not significantly increase the level of disturbance (that is, 
more than 2 dB) or significantly degrade the immunity level.  
The test mode(s) described in Item 2.4 were scanned during the preliminary test. After the 
preliminary scan, we found the test mode described in Item 2.4 producing the highest 
emission level. The EUT and cable configuration, antenna position, polarization and turntable 
position of the above highest emission level were recorded for the final test. 
Procedure of Final Test 
EUT and support equipment were set up on the turntable as per the configuration with highest 
Report No.:  EM201200813-6                Application No.:  ZJ00024740                        Page 11 of 61 
 
emission level in the preliminary test. The Analyzer / Receiver scanned from 30MHz to 
300MHz. Emissions were scanned and measured rotating the EUT to 360 degrees, varying 
cable placement and positioning the antenna 1 to 4 meters above the ground plane, in both the 
vertical and the horizontal polarization, to maximize the emission reading level. Record at 
least six highest emissions. Emission frequency, amplitude, antenna position, polarization 
and turntable position were recorded into a computer in which correction factors were used to 
calculate the emission level and compare reading to the applicable limit and only QP reading 
is presented. The test data of the worst-case condition(s) was recorded. 
4.1.3 TEST SETUP 
 
Figure 1. 30MHz to 1GHz radiated emissions test configuration
 
 
 
Figure 2. Above 1GHz radiated emissions test configuration 
Report No.:  EM201200813-6                Application No.:  ZJ00024740                        Page 12 of 61 
 
 
4.1.4 TEST RESULTS 
           
Project No.: 
ZJ00022653 
Polarziation: 
Horizontal 
Standard: 
(RE)EN55022_class B_3m 
Power Source: 
AC 230V/50Hz 
Test item: 
Radiation Test 
Date: 
2013-01-11 
Temp./Hum.(%RH): 23/55%RH 
Time: 
10:09:14 
EUT: JBL 
PlayUp 
Distance: 
3m 
Model: 
JBL ONBEAT RUMBLE 
Test Result: 
Pass 
Note:  
BT (Loading and headset) 
 
 
 
 
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBuV/m) 
Factor(dB/m)
(dBuV/m) 
(dBuV/m) 
(dB) 
 
1 67.7634 23.48  7.72  31.20 40.00 -8.80  QP 
2 73.7229 20.92  7.98  28.90 40.00 -11.10  QP 
3 110.4892 12.44  9.46  21.90  40.00 -18.10  QP 
4 187.3820 14.74  11.36  26.10  40.00 -13.90  QP 
5 206.1657 20.98  11.72  32.70  40.00  -7.30  QP 
6 218.0829 17.82  12.38  30.20  40.00  -9.80  QP 
 