EMC - CB Certificate
Brand
Device
Audio
File
on-beat-air-sm3.pdf
Date

JBL ON BEAT AIR (serv.man3) EMC - CB Certificate ▷ View online

 
 
www.tuv.com 
Page 8 of 116 
Report No.: 11023927 001 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
GENERAL 
 
1.5 
Components 
1.5.1 
General 
 
 
Comply with IEC 60950-1 or relevant component 
standard  
(see appended tables 1.5.1) 
1.5.2 
Evaluation and testing of components 
Components which are 
certified to IEC and/or 
national standards are used 
correctly within their ratings. 
Components not covered by 
IEC standards are tested 
under the conditions present 
in the equipment. 
1.5.3 
Thermal controls 
No thermal controls. 
N/A 
1.5.4 
Transformers 
Transformers used are 
suitable for their intended 
application and comply with 
the relevant requirements of 
the standard and particularly 
Annex C. 
1.5.5 
Interconnecting cables 
SELV output cable provided 
as part of this equipment and 
no higher energy levels than 
240VA, it’s not possible to 
present a hazard. 
1.5.6 
Capacitors bridging insulation  
Between lines: X2 type 
capacitor (CX) according to 
IEC 60384-14.                
Between primary and 
secondary: Y1 capacitor 
(CY1), according to IEC 
60384-14.                
1.5.7 
Resistors bridging insulation 
 
1.5.7.1 
Resistors bridging functional, basic or 
supplementary insulation 
Only discharge resistors 
bridging insulation between 
L&N. 
1.5.7.2 
Resistors bridging double or reinforced insulation 
between a.c. mains and other circuits 
Between primary and 
secondary: By resistors R36-
R41. 
1.5.7.3 
Resistors bridging double or reinforced insulation 
between a.c. mains and antenna or coaxial cable  
 
N/A 
1.5.8 
Components in equipment for IT power systems 
See only Norway deviation 
N/A 
 
 
www.tuv.com 
Page 9 of 116 
Report No.: 11023927 001 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
1.5.9 
Surge suppressors 
No such components 
N/A 
1.5.9.1 
General 
 
N/A 
1.5.9.2 
Protection of VDRs 
 
N/A 
1.5.9.3 
Bridging of functional insulation by a VDR 
 
N/A 
1.5.9.4 
Bridging of basic insulation by a VDR 
 
N/A 
1.5.9.5 
Bridging of supplementary, double or reinforced 
insulation by a VDR 
 
N/A 
 
1.6 
Power interface 
1.6.1 
AC power distribution systems 
TN power system  
1.6.2 
Input current 
Highest load according to 
1.2.2.1 for this equipment is 
the operation with the 
maximum specified by the 
manual instruction. (see 
appended table 1.6.2)  
1.6.3 
Voltage limit of hand-held equipment 
This appliance is not hand-
held equipment. 
N/A 
1.6.4 
Neutral conductor  
The neutral conductor 
insulated from earth and from 
the body throughout the 
equipment as if it were a line 
conductor 
 
1.7 
Marking and instructions 
1.7.1 
Power rating and identification markings 
See below 
1.7.1.1 
Power rating marking 
 
 
Multiple mains supply connections..........................:  Single power source 
 
Rated voltage(s) or voltage range(s) (V)  .............. :  100-240V~ 
 
Symbol for nature of supply, for d.c. only .............. :  AC source 
N/A 
 
Rated frequency or rated frequency range (Hz)  ... :  50/60Hz 
 
Rated current (mA or A) ........................................ :  1.5A  
1.7.1.2 
Identification markings 
 
 
Manufacturer’s name or trade-mark or identification 
mark  ...................................................................... : 
 
 
Model identification or type reference ................... :  See page 5 
 
 
www.tuv.com 
Page 10 of 116 
Report No.: 11023927 001 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
 
Symbol for Class II equipment only  ...................... :  60417-1-IEC-5172 symbol 
marked. 
 
Other markings and symbols  ................................ :  Additional symbol or marking 
does not give rise to 
misunderstanding. 
1.7.2 
Safety instructions and marking 
English and Germany version 
provide. 
(Version in other language will 
be provided when submitted 
for national approval) 
1.7.2.1 
General 
 
1.7.2.2 
Disconnect devices 
Appliance inlet serves as 
disconnect device. 
1.7.2.3 
Overcurrent protective device 
Not such equipment. 
N/A 
1.7.2.4 
IT power distribution systems 
 
N/A 
1.7.2.5 
Operator access with a tool 
No operator accessible area 
that needs to be accessed by 
the use of a tool. 
N/A 
1.2.7.6 
Ozone 
Not such equipment. 
N/A 
1.7.3 
Short duty cycles 
Equipment is designed for 
continuous operation. 
N/A 
1.7.4 
Supply voltage adjustment ................................... : 
No voltage selector. 
N/A 
 
Methods and means of adjustment; reference to 
installation instructions ......................................... : 
 
N/A 
1.7.5 
Power outlets on the equipment  .......................... : 
No power outlets provided. 
N/A 
1.7.6 
Fuse identification (marking, special fusing 
characteristics, cross-reference) .......................... : 
Fuse marking provided on 
PCB:F1 T3.15A 250V  
1.7.7 
Wiring terminals 
See below. 
1.7.7.1 
Protective earthing and bonding terminals  .......... : 
Class I equipment. Protective 
earthing terminal symbol 
marked on appliance inlet. 
1.7.7.2 
Terminals for a.c. mains supply conductors  
The equipment with appliance 
inlet is intended to use the 
detachable type power supply 
cord. 
N/A 
1.7.7.3 
Terminals for d.c. mains supply conductors 
No d.c. mains supply. 
N/A 
1.7.8 
Controls and indicators 
No controls and indicators 
N/A 
1.7.8.1 
Identification, location and marking  ..................... : 
 
N/A 
1.7.8.2 
Colours  ................................................................ : 
 
N/A 
 
 
www.tuv.com 
Page 11 of 116 
Report No.: 11023927 001 
IEC 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60950_1B 
 
1.7.8.3 
Symbols according to IEC 60417 ........................ : 
 
N/A 
1.7.8.4 
Markings using figures   ....................................... : 
 
N/A 
1.7.9 
Isolation of multiple power sources  .................... : 
Single power source 
N/A 
1.7.10 
Thermostats and other regulating devices  ......... : 
Such devices not used. 
N/A 
1.7.11 
Durability 
The label was subjected to 
the permanence of marking 
test. The label was rubbed 
with cloth soaked with water 
for 15 sec. And then again for 
15 sec. With the cloth soaked 
with petroleum spirit. 
After this test there was no 
damage to the label. The 
marking on the label did not 
fade. There was no curling 
and lifting of the label edge. 
1.7.12 
Removable parts 
No removable part. 
N/A 
1.7.13 
Replaceable batteries  ......................................... : 
No battery provided. 
N/A 
 
Language(s) .........................................................: 
 
 
1.7.14 
Equipment for restricted access locations ........... : 
Not intended for use in 
restricted access locations. 
N/A 
 
PROTECTION FROM HAZARDS 
2.1 
Protection from electric shock and energy hazards 
2.1.1 
Protection in operator access areas  
No access with test finger and 
test pin to any parts with only 
basic insulation to ELV or 
hazardous voltage. 
2.1.1.1 
Access to energized parts 
See above. 
 
Test by inspection  .................................................:   
 
Test with test finger (Figure 2A)  ............................:   
 
Test with test pin (Figure 2B)  ................................:   
 
Test with test probe (Figure 2C) ............................:   
N/A 
2.1.1.2 
Battery compartments  
No battery compartment. 
N/A 
2.1.1.3 
Access to ELV wiring 
No ELV wiring in operator 
accessible area. 
N/A 
 
Working voltage (Vpeak or Vrms); minimum 
distance through insulation (mm) 
(see appended table 2.10.5)  
 