JBL ON BEAT AIR (serv.man3) EMC - CB Certificate ▷ View online
www.tuv.com
Page 4 of 116
Report No.: 11023927 001
TRF No. IEC60950_1B
Summary of compliance with National Differences
List of countries addressed:
EU Group Differences, EU Special National Conditions, AT, AU, BE, CA, CH, CN, CZ, DE, DK, FI, GB,
JP, KR, NL, NO, PL, SE, SI, US
JP, KR, NL, NO, PL, SE, SI, US
Explanation of used codes:
AT=Austria, AU=Australia, BE=Belgium, CA=Canada, CH=Switzerland, CN=China, CZ=Czech Republic,
DE=Germany, DK=Denmark, FI=Finland, GB=United Kingdom, JP=Japan, KR=Korea, NL=The
Netherlands, NO=Norway, PL=Poland, SE=Sweden, SI=Slovenia, US=USA
National differences of Canada and USA attached are considered according to IEC 60950-1:2005 only.
National differences of Australia are considered according to AS/NZS 60950-1: 2003+A1+A2+A3 (IEC
Publication 60950-1:2001).
For Japan deviation, special National conditions, National deviation and other information according to MITI
Ordinance No. 85. have been considered. (IEC Publication 60950 3rd edition, 1999)
Copy of marking plate
The use of certification marks on a product must be authorized by the respective NCBs that own
these marks.
these marks.
Remark: All models rating label are in the same design except for type designation. Above labels for
representing the other models.
representing the other models.
www.tuv.com
Page 5 of 116
Report No.: 11023927 001
TRF No. IEC60950_1B
Test item particulars ..................................................:
Equipment mobility.....................................................: [x] movable [] hand-held [] transportable
[] stationary [] for building-in [] direct plug-in
Connection to the mains ............................................: [x] pluggable equipment [x] type A [] type B
[] permanent connection
[x] detachable power supply cord
[] non-detachable power supply cord
[] not directly connected to the mains
[x] detachable power supply cord
[] non-detachable power supply cord
[] not directly connected to the mains
Operating condition....................................................: [x] continuous
[] rated operating / resting time:
Access location .........................................................: [x] operator accessible
[] restricted access location
Over voltage category (OVC) ...................................: [] OVC I [x] OVC II [] OVC III [] OVC IV
[] other:
Mains supply tolerance (%) or absolute mains supply
values ........................................................................:
values ........................................................................:
±
10% (requested by client)
Tested for IT power systems ....................................: [x] Yes (only for Norway) [] No
IT testing, phase-phase voltage (V) ..........................: 230V
Class of equipment ...................................................: [x] Class I [] Class II [] Class III
[] Not classified
Considered current rating of protective device as
part of the building installlation (A) ............................:
part of the building installlation (A) ............................:
16A
Pollution degree (PD) ...............................................: [] PD 1 [x] PD 2 [] PD 3
IP protection class .....................................................: IP20
Altitude during operation (m) ....................................: Up to 2000
Altitude of test laboratory (m) ....................................: below 2000
Mass of equipment (kg) ............................................: 0.168
Possible test case verdicts:
- test case does not apply to the test object ................ : N/A
- test object does meet the requirement ...................... : P (Pass)
- test object does not meet the requirement ................ : F (Fail)
Testing.......................................................................... :
Date of receipt of test item............................................ : Jan. 07, 2010
Date(s) of performance of tests.................................... : Jan. 2010
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a point is used as the decimal separator.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a point is used as the decimal separator.
www.tuv.com
Page 6 of 116
Report No.: 11023927 001
TRF No. IEC60950_1B
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided ................................................................:
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory has
been provided ................................................................:
Yes
Not applicable
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies)...........................: Dongguan Sunstrong Electric Machine
Company Limited.
Sunstrong Industrial Park, Sicun Administration
Zone, Tangxia Town, Dongguan, Guangdong, P.R.
China.
China.
General product information:
This test report covers models SSA-60W-x ab (see below table for variable) with appliance inlet
which are switching mode power supply intended to use for for use with information technology
equipment.
Top enclosure and bottom enclosure are sealed together by ultrasonic welding.
which are switching mode power supply intended to use for for use with information technology
equipment.
Top enclosure and bottom enclosure are sealed together by ultrasonic welding.
Max. ambient temperature +40°C.
Definition of variable:
Variable:
Range of variable:
Content:
x
12, 20 or 30
Indicate output voltage’s range, 12 represent for output
voltage from 12.0V – 18.0V; 20 represent for output
voltage from 18.1V – 30.0V; 30 represent for output
voltage from 30.1V – 48.0V;
voltage from 12.0V – 18.0V; 20 represent for output
voltage from 18.1V – 30.0V; 30 represent for output
voltage from 30.1V – 48.0V;
a
120 - 480
3 digits, indicate 10 times output voltage in Vol., the
minimum step is 0.1V. eg: 120=12.0V, 480=48.0V.
minimum step is 0.1V. eg: 120=12.0V, 480=48.0V.
b
010 - 360
3 digits, indicate 100 times output current in A, the
minimum step is 0.01A. eg: 010=0.1A, 360=3.6A.
minimum step is 0.01A. eg: 010=0.1A, 360=3.6A.
Notes: All models have the same circuit diagram, PCB layout except for transformer, output rating and
some component ratings (see below table for detail).
some component ratings (see below table for detail).
www.tuv.com
Page 7 of 116
Report No.: 11023927 001
TRF No. IEC60950_1B
Table A: Output ratings
Model No.
Output
Voltage
(Vdc)
Output
Current
(mA)
Output
Power
(Max. W)
Transformer
12.0
10-3600
43.2
12.1 – 15.0
10-3200
48.0
SSA-60W-12 ab
15.1 - 18.0
10-3000
54.0
SSA-60W-12
18.1 – 20.0
10-2700
54.0
20.1 – 26.0
10-2400
55.2
SSA-60W-20 ab
26.1 – 30.0
10-2000
56.0
SSA-60W-20
30.1 – 36.0
10-1700
54.4
SSA-60W-30 ab
36.1 – 48.0
10-1400
57.6
SSA-60W-30
Notes: The output voltage is rising in steps of 0.1V. The output current is rising in steps of 0.01A. The
output voltage multiplied with output current is only tested up to the max. output power.
output voltage multiplied with output current is only tested up to the max. output power.
Models difference
Models
Components
SSA-60W-12 ab
SSA-60W-20 ab
SSA-60W-30 ab
R6
10-33ohm
10ohm
10ohm
R7
10-120ohm
10-120ohm
10-120ohm
R20 R21
620-910Kohm
620-910Kohm
620-910Kohm
R22 R23
10-200ohm
10-200ohm
10-200ohm
R24
200ohm-1kohm
200-2.2Kohm
2.2-6.8Kohm
R25
2.4Kohm
2.4Kohm
68Kohm
R26
22-100Kohm
22-100Kohm
68-330Kohm
R34
4.7K-10kohm
7.5K-15kohm
15k-68Kohm
C5 C6
680pF -2.2nF
680pF-1nF
680pF-1nF
C7 C8
470 uF -680uF
16Vor25V
220 uF-680uF 25V
100uF 63V
C9
100-220uF 16Vor25V
100-220uF 25V
22-47uF 50V or 63V
T1
SSA-60W-12
SSA-60W-20
SSA-60W-30
Abbreviations used in the report:
- normal conditions
N.C.
- single fault conditions
S.F.C
- functional insulation
OP
- basic insulation
BI
- double insulation
DI
- supplementary insulation
SI
- between parts of opposite
polarity
polarity
BOP
- reinforced insulation
RI