Report No.: 1009950
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
5.4.1
Norway and Sweden
To the end of 5.4.1 (after the compliance
statement) the following is added:
The screen of the cable distribution system is
normally not earthed at the entrance of the building
and there is normally no equipotential bonding
system within the building. Therefore the protective
earthing of the building installation need to be
isolated from the screen of a cable distribution
system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
“Equipment connected to the protective earthing of
the building installation through the mains
connection or through other equipment with a
connection to protective earthing – and to a cable
distribution system using coaxial cable, may in
some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device providing
electrical isolation below a certain frequency range
(galvanic isolator, see EN 60728-11)”
To the end of 5.4.1 (after the compliance
statement) the following is added:
The screen of the cable distribution system is
normally not earthed at the entrance of the building
and there is normally no equipotential bonding
system within the building. Therefore the protective
earthing of the building installation need to be
isolated from the screen of a cable distribution
system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
“Equipment connected to the protective earthing of
the building installation through the mains
connection or through other equipment with a
connection to protective earthing – and to a cable
distribution system using coaxial cable, may in
some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device providing
electrical isolation below a certain frequency range
(galvanic isolator, see EN 60728-11)”
NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,
for 1 min.
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,
for 1 min.
Translation to Norwegian (the Swedish text will also
be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet utstyr – og
er tilkoplet et kabel-TV nett, kan forårsake
brannfare. For å unngå dette skal det ved tilkopling
av utstyret til kabel-TV nettet installeres en
galvanisk isolator mellom utstyret og kabel-TV
nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via jordat
vägguttag och/eller via annan utrustning och
samtidigt är kopplad till kabel-TV nät kan i vissa fall
medföra risk för brand.
Főr att undvika detta skall vid anslutning av
utrustningen till kabel-TV nät galvanisk isolator
finnas mellan utrustningen och kabel-TV nätet.”
be accepted in Norway):
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet utstyr – og
er tilkoplet et kabel-TV nett, kan forårsake
brannfare. For å unngå dette skal det ved tilkopling
av utstyret til kabel-TV nettet installeres en
galvanisk isolator mellom utstyret og kabel-TV
nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via jordat
vägguttag och/eller via annan utrustning och
samtidigt är kopplad till kabel-TV nät kan i vissa fall
medföra risk för brand.
Főr att undvika detta skall vid anslutning av
utrustningen till kabel-TV nät galvanisk isolator
finnas mellan utrustningen och kabel-TV nätet.”
N/A
Page 55 of 58
Report No.: 1009950
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
15.1.1
Denmark
The text of the Danish SNC in EN 60065:2002 has
been modified as follows:
been modified as follows:
To the first paragraph the following is added:
In Denmark, supply cords of single-phase
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with the
Heavy Current Regulations, Section 107-2-D1
standard sheet DK 2-1a.
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with the
Heavy Current Regulations, Section 107-2-D1
standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for providing power to
CLASS II apparatus with a rated current of 2,5 A
shall be in accordance with the Heavy Current
Regulation, Section 107-2-D1 standard sheet DKA
1-4a.
CLASS II apparatus with a rated current of 2,5 A
shall be in accordance with the Heavy Current
Regulation, Section 107-2-D1 standard sheet DKA
1-4a.
Other current ratings socket outlets shall be in
compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DKA 1-3a or DKA
1-3b.
compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DKA 1-3a or DKA
1-3b.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be
in compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DK 1-3a, DK 1-5a
or DK 1-7a.
in compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DK 1-3a, DK 1-5a
or DK 1-7a.
Justification: Heavy Current Regulations, Section
107-2-D1
107-2-D1
N/A
Page 56 of 58
Report No.: 1009950
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
National differences SINGAPORE
IEC 60065:2001 + A1
NOTE: (These differences are taken from IEC 60065:1993 and adopted to
IEC 60065:2001)
Throughout the standard, whenever the words
"white pine board" appear, insert the words "or
plywood board" to it.
"white pine board" appear, insert the words "or
plywood board" to it.
SS143 Amendment No. 1 and No. 2
4.1.3
(4.1.3)*
Delete "45 % to 75 % and insert "65 ± 5 %".
75% maximum in IEC
60065:2001
60065:2001
P
7.1
(7.1)
Resistance to heat without external forces.
Adopt the temperature specified for the tropical
conditions.
conditions.
P
8.6
(9.3.4)
Delete the note "A Quality Assessment System
for capacitors complying with Subclause 14.2 is
under consideration in the IEC".
for capacitors complying with Subclause 14.2 is
under consideration in the IEC".
This is not in IEC 60065:2001
P
10.2
(10.2)
Humidity treatment
Adopt the testing conditions designed for tropical
conditions.
conditions.
120h at 93% rel. humidity
P
16
(16)
External flexible cords
Delete "IEC Publication 60227: Polyvinyl Chloride
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC publication 60245:
Rubber insulated Cables of rated up to and
including 450/750 V " and insert "Singapore
Standard 236: Flexible Cords", whenever they
appear in this clause.
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC publication 60245:
Rubber insulated Cables of rated up to and
including 450/750 V " and insert "Singapore
Standard 236: Flexible Cords", whenever they
appear in this clause.
Delete "CEE Publication 13, CEE Publication 2
and IEC Publication 60173: Colours of the Cores
of Flexible Cables and Cords" whenever they
appear in this clause.
and IEC Publication 60173: Colours of the Cores
of Flexible Cables and Cords" whenever they
appear in this clause.
P
16.2
(16.2)
Delete the notes in small print and insert "A
nominal cross-sectional area of 0.75 mm² will
satisfy this requirement".
nominal cross-sectional area of 0.75 mm² will
satisfy this requirement".
This is not in IEC 60065:2001
P
Page 57 of 58
Report No.: 1009950
IEC60065 - ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
16.3b
(16.4b)
Delete “Subclause 3.1 of IEC Publication 60227-2:
Part 2: Test Methods“ and insert “Subclause 9.1 of
SS 236“:
9.1 Flexing test (except for tinsel cords, twisted
twin and single core cords). The test shall be
carried out by means of the apparatus shown in
Figure 5. This apparatus has a carrier C supporting
two pulleys A and B arranged so that the cord is
horizontal between the pulleys. The carrier moves
backward and forward over a distance of 1 m at an
approximately constant speed of 0.33 m/s.
A sample of flexible cord about 5 m long shall be
stretched over the pulleys as shown in the figure,
each end being loaded with a weight. The weight
and the diameter of the pulleys A and B shall be
given in Table 1.
Part 2: Test Methods“ and insert “Subclause 9.1 of
SS 236“:
9.1 Flexing test (except for tinsel cords, twisted
twin and single core cords). The test shall be
carried out by means of the apparatus shown in
Figure 5. This apparatus has a carrier C supporting
two pulleys A and B arranged so that the cord is
horizontal between the pulleys. The carrier moves
backward and forward over a distance of 1 m at an
approximately constant speed of 0.33 m/s.
A sample of flexible cord about 5 m long shall be
stretched over the pulleys as shown in the figure,
each end being loaded with a weight. The weight
and the diameter of the pulleys A and B shall be
given in Table 1.
Screen cords in accordance with Table 7 shall be
tested before application of the screen and outer
sheath.
tested before application of the screen and outer
sheath.
The pulleys shall have a semi-circular shaped
groove for circular cords and a flat groove for
parallel twin cords. The restraining clamps D shall
be fixed so that the pull is always applied by the
weight from which the carrier is moving away.
The carrier shall make 30 000 backward and
forward movements (60 000 single strokes). Each
conductor of the sample shall be loaded with the
current specified in Table 2.
groove for circular cords and a flat groove for
parallel twin cords. The restraining clamps D shall
be fixed so that the pull is always applied by the
weight from which the carrier is moving away.
The carrier shall make 30 000 backward and
forward movements (60 000 single strokes). Each
conductor of the sample shall be loaded with the
current specified in Table 2.
For twin cords and for light PVC-sheated 3-core
cords, the voltage between the conductors shall
be approximately 230 V a.c. For all other cords
having three or more cores a three-phase a.c.
voltage of about 400 V shall be applied to three
conductors, any additional conductors being
connected to the neutral.
cords, the voltage between the conductors shall
be approximately 230 V a.c. For all other cords
having three or more cores a three-phase a.c.
voltage of about 400 V shall be applied to three
conductors, any additional conductors being
connected to the neutral.
During the test no open-circuit in any core or
short-circuit between cores shall occur.
short-circuit between cores shall occur.
After the test, any sheath on cords having three
or more cores shall be removed. The cord, or the
laid up cores, shall then withstand the voltage
test specified in Subclause 8.2 or 8.3 as
appropriate, but with a test voltage not exceeding
2000 V.
or more cores shall be removed. The cord, or the
laid up cores, shall then withstand the voltage
test specified in Subclause 8.2 or 8.3 as
appropriate, but with a test voltage not exceeding
2000 V.
TABLE 1, TABLE 2, FIGURES 4 and 5, see the
CB BULLETIN
P
* in parenthesis: clauses acc. to IEC 60065:1993