DOWNLOAD JBL ES 150P (serv.man2) Service Manual ↓ Size: 1.09 MB | Pages: 32 in PDF or view online for FREE

Model
ES 150P (serv.man2)
Pages
32
Size
1.09 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
es-150p-sm2.pdf
Date

JBL ES 150P (serv.man2) EMC - CB Certificate ▷ View online

 
mikes-testingpartners gmbh
 File 
No. 
F31764-00-00HM
, page 
28 of 31 
Ohmstrasse 2-4 
x 94342 Strasskirchen
 
Tel.:+49(0)9424-94810 
x Fax:+49(0)9424-9481240 
Rev. No. 1.3 
7   T e s t  p r o t o c o l ( s )  
 
 
7.1 
Immunity requirements - S2 Test protocol(s) 
 
 
 
 
Test point (injection into) : LFE 
Mode of EUT : LFE 
Criterion : Sound 
Ref.-S/N :  56 dB 
Monitoring : Speaker 
Output : 53 mW/4 Ohm 
Channel : left 
Start Margin : 6 dB over limit 
Test Engineer : Rüdiger Gramsch 
Date : 24.05.2007 
Place :  Immunity Site 1 
 
 
 
 
Test point (injection into) : LFE 
Mode of EUT : LINE 
Criterion : Sound 
Ref.-S/N :  60 dB 
Monitoring : Speaker 
Output : 50 mW/4 Ohm 
Channel : left 
Start Margin : 6 dB over limit 
Test Engineer : Rüdiger Gramsch 
Date : 24.05.2007 
Place :  Immunity Site 1 
 
 
 
mikes-testingpartners gmbh
 File 
No. 
F31764-00-00HM
, page 
29 of 31 
Ohmstrasse 2-4 
x 94342 Strasskirchen
 
Tel.:+49(0)9424-94810 
x Fax:+49(0)9424-9481240 
Rev. No. 1.3 
 
 
Test point (injection into) : LINE IN 
Mode of EUT : LFE 
Criterion : Sound 
Ref.-S/N :  57 dB 
Monitoring : Speaker 
Output : 54 mW/4 Ohm 
Channel : left 
Start Margin : 6 dB over limit 
Test Engineer : Rüdiger Gramsch 
Date : 24.05.2007 
Place :  Immunity Site 1 
 
 
 
 
Test point (injection into) : LINE IN 
Mode of EUT : LINE 
Criterion : Sound 
Ref.-S/N :  59 dB 
Monitoring : Speaker 
Output : 50 mW/4 Ohm 
Channel : left 
Start Margin : 6 dB over limit 
Test Engineer : Rüdiger Gramsch 
Date : 24.05.2007 
Place :  Immunity Site 1 
 
 
 
 
Test point (injection into) : MAINS 
Mode of EUT : LFE 
Criterion : Sound 
Ref.-S/N :  57 dB 
Monitoring : Speaker 
Output : 52 mW/4 Ohm 
Channel : left 
Start Margin : 6 dB over limit 
Test Engineer : Rüdiger Gramsch 
Date : 24.05.2007 
Place :  Immunity Site 1 
 
mikes-testingpartners gmbh
 File 
No. 
F31764-00-00HM
, page 
30 of 31 
Ohmstrasse 2-4 
x 94342 Strasskirchen
 
Tel.:+49(0)9424-94810 
x Fax:+49(0)9424-9481240 
Rev. No. 1.3 
 
 
 
 
Test point (injection into) : MAINS 
Mode of EUT : LINE 
Criterion : Sound 
Ref.-S/N :  63 dB 
Monitoring : Speaker 
Output : 52 mW/4 Ohm 
Channel : left 
Start Margin : 6 dB over limit 
Test Engineer : Rüdiger Gramsch 
Date : 24.05.2007 
Place :  Immunity Site 1 
 
 
 
7.2 
Immunity requirements - S3 Test protocol(s) 
 
 
 
 
Mode of EUT : LFE 
Criterion : Sound 
Ref.-S/N :  58 dB 
Monitoring : Speaker 
Output : 45 mW/4 Ohm 
Channel : left 
Start Margin : 6 dB over limit 
K2 Factor : 1,8 dB 
 
 
Test Engineer : Rüdiger Gramsch 
Date : 24.05.2007 
Place :  Immunity Site 1 
 
Frequency Level 
Limit  Margin Frequency Level 
Limit  Margin 
[MHz] [dB(µV/m)] 
[dB(µV/m)]  [dB] 
[MHz] [dB(µV/m)] [dB(µV/m)]  [dB] 
122 130 125  5  123 130 125  5 
127 130 125  5  128 130 125  5 
132 130 125  5  137 130 125  5 
138 128 125  3  139 128 125  3 
140 128 125  3  141 128 125  3 
142 129 125  4  145 129 125  4 
 
 
 
mikes-testingpartners gmbh
 File 
No. 
F31764-00-00HM
, page 
31 of 31 
Ohmstrasse 2-4 
x 94342 Strasskirchen
 
Tel.:+49(0)9424-94810 
x Fax:+49(0)9424-9481240 
Rev. No. 1.3 
 
 
Mode of EUT : LINE 
Criterion : Sound 
Ref.-S/N :  58 dB 
Monitoring : Speaker 
Output : 43 mW/4 Ohm 
Channel : left 
Start Margin : 6 dB over limit 
K2 Factor : 1,8 dB 
 
 
Test Engineer : Rüdiger Gramsch 
Date : 24.05.2007 
Place :  Immunity Site 1 
 
 
Page of 32
Display

JBL ES 150P (serv.man2) EMC - CB Certificate ▷ Download