7 T e s t p r o t o c o l ( s )
7.1
Immunity requirements - S2 Test protocol(s)
Test point (injection into) : LFE
Mode of EUT : LFE
Criterion : Sound
Ref.-S/N : 56 dB
Monitoring : Speaker
Output : 53 mW/4 Ohm
Channel : left
Start Margin : 6 dB over limit
Test Engineer : Rüdiger Gramsch
Date : 24.05.2007
Place : Immunity Site 1
Test point (injection into) : LFE
Mode of EUT : LINE
Criterion : Sound
Ref.-S/N : 60 dB
Monitoring : Speaker
Output : 50 mW/4 Ohm
Channel : left
Start Margin : 6 dB over limit
Test Engineer : Rüdiger Gramsch
Date : 24.05.2007
Place : Immunity Site 1
mikes-testingpartners gmbh
File
No.
F31764-00-00HM
, page
29 of 31
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.3
Test point (injection into) : LINE IN
Mode of EUT : LFE
Criterion : Sound
Ref.-S/N : 57 dB
Monitoring : Speaker
Output : 54 mW/4 Ohm
Channel : left
Start Margin : 6 dB over limit
Test Engineer : Rüdiger Gramsch
Date : 24.05.2007
Place : Immunity Site 1
Test point (injection into) : LINE IN
Mode of EUT : LINE
Criterion : Sound
Ref.-S/N : 59 dB
Monitoring : Speaker
Output : 50 mW/4 Ohm
Channel : left
Start Margin : 6 dB over limit
Test Engineer : Rüdiger Gramsch
Date : 24.05.2007
Place : Immunity Site 1
Test point (injection into) : MAINS
Mode of EUT : LFE
Criterion : Sound
Ref.-S/N : 57 dB
Monitoring : Speaker
Output : 52 mW/4 Ohm
Channel : left
Start Margin : 6 dB over limit
Test Engineer : Rüdiger Gramsch
Date : 24.05.2007
Place : Immunity Site 1
mikes-testingpartners gmbh
File
No.
F31764-00-00HM
, page
30 of 31
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.3
Test point (injection into) : MAINS
Mode of EUT : LINE
Criterion : Sound
Ref.-S/N : 63 dB
Monitoring : Speaker
Output : 52 mW/4 Ohm
Channel : left
Start Margin : 6 dB over limit
Test Engineer : Rüdiger Gramsch
Date : 24.05.2007
Place : Immunity Site 1
7.2
Immunity requirements - S3 Test protocol(s)
Mode of EUT : LFE
Criterion : Sound
Ref.-S/N : 58 dB
Monitoring : Speaker
Output : 45 mW/4 Ohm
Channel : left
Start Margin : 6 dB over limit
K2 Factor : 1,8 dB
Test Engineer : Rüdiger Gramsch
Date : 24.05.2007
Place : Immunity Site 1
Frequency Level
Limit Margin Frequency Level
Limit Margin
[MHz] [dB(µV/m)]
[dB(µV/m)] [dB]
[MHz] [dB(µV/m)] [dB(µV/m)] [dB]
122 130 125 5 123 130 125 5
127 130 125 5 128 130 125 5
132 130 125 5 137 130 125 5
138 128 125 3 139 128 125 3
140 128 125 3 141 128 125 3
142 129 125 4 145 129 125 4
127 130 125 5 128 130 125 5
132 130 125 5 137 130 125 5
138 128 125 3 139 128 125 3
140 128 125 3 141 128 125 3
142 129 125 4 145 129 125 4
mikes-testingpartners gmbh
File
No.
F31764-00-00HM
, page
31 of 31
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.3
Mode of EUT : LINE
Criterion : Sound
Ref.-S/N : 58 dB
Monitoring : Speaker
Output : 43 mW/4 Ohm
Channel : left
Start Margin : 6 dB over limit
K2 Factor : 1,8 dB
Test Engineer : Rüdiger Gramsch
Date : 24.05.2007
Place : Immunity Site 1