JBL ES 150P (serv.man2) EMC - CB Certificate ▷ View online
mikes-testingpartners gmbh
File
No.
F31764-00-00HM
, page
8 of 31
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.3
4 T E S T E N V I R O N M E N T
4.1
Address of the test laboratory
mikes-testingpartners gmbh
Ohmstrasse
2-4
94342
Strasskirchen
Germany
4.2 Environmental
conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature:
15-35 ° C
Humidity: 30-60
%
Atmospheric pressure:
86-106 kPa
4.3
Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there may
be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated
for all measurements listed in this test report acc. to CISPR 16-4-2 /11.2003 „Uncertainties, statistics and limit
modelling – Uncertainty in EMC measurements“ and is documented in the quality system acc. to DIN EN ISO/IEC
17025. Furthermore, component and process variability of devices similar to that tested may result in additional
deviation. The manufacturer has the sole responsibility of continued compliance of the device.
mikes-testingpartners gmbh
File
No.
F31764-00-00HM
, page
9 of 31
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.3
5 T E S T C O N D I T I O N S A N D R E S U L T S
5.1 Conducted
disturbance
For test instruments and accessories used see section 6 Part A 4.
5.1.1 Description of the test location
Test location:
Test location:
Shielded Room S3
5.1.2 Photo documentation of the test set-up
5.1.3 Test
result
Frequency range:
0.15 MHz - 30 MHz
Min. limit margin
>5 dB
The requirements are
FULFILLED.
Remarks:
For detailed results, please see the following page(s).
mikes-testingpartners gmbh
File
No.
F31764-00-00HM
, page
10 of 31
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.3
5.1.4 Test
protocol
Test point:
L1
Operation mode:
60 Hz 1/8 rated output power
Remarks: N/A
Date:
Date:
24. May 2007
Tested by:
Rüdiger Gramsch
Result: passed
Peak Measurement
See Table for QP and AV v alues
L1 OM1
100.0K
1.0M
10.0M
100.0M
Frequency
0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
110.0
120.0
A
m
p
lit
ude
dB
(µ
V
)
File Number: F31764
Standard: EN55013
Equipment - ES150P/230
Serial No. - none
Op Mode 1 - 60 Hz 1/8 power
Operator - GR
LmtAVVoltage
LmtQPVoltage
Peak_11
AVG_11
QP_11
AV_11
LmtQPVoltage
Peak_11
AVG_11
QP_11
AV_11
Frequency
QP Level
QP Margin
QP Limit
AV Level
AV Margin
AV Limit
MHz dB(µV) dB dB dB(µV) dB dB
0.000
22.2
22.2 22 22.2 22.2 22
0.235 50.1 -12.2 62.3 40.7 -11.6 52.3
0.35 44.2
0.35 44.2
-14.8 59.0 37.0 -12.0 49.0
0.47 40.8
-15.7 56.5 27.4 -19.1 46.5
0.595 4.6 -51.4 56.0 1.5
-44.5 46.0
1.98 39.6
-16.4 56.0 23.6 -22.4 46.0
3.545 13.6 -42.4 56.0 2.7
-43.3 46.0
4.42 39.8
-16.2 56.0 16.3 -29.8 46.0
6.975 32.3 -27.7 60.0 7.8
-42.2 50.0
8 38.6
-21.4
60.0
11.0 -39.0 50.0
8.235 38.1 -21.9 60.0 8.1
-41.9 50.0
mikes-testingpartners gmbh
File
No.
F31764-00-00HM
, page
11 of 31
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.3
Test point:
N
Operation mode:
60 Hz 1/8 rated output power
Remarks: N/A
Date:
Date:
24. May 2007
Tested by:
Rüdiger Gramsch
Result: passed
Peak Measurement
See Table for QP and AV v alues
N OM1
100.0K
1.0M
10.0M
100.0M
Frequency
0
10.0
20.0
30.0
40.0
50.0
60.0
70.0
80.0
90.0
100.0
110.0
120.0
A
m
p
lit
ude
dB
(µ
V
)
File Number: F31764
Standard: EN55013
Equipment - ES150P/230
Serial No. - none
Op Mode 1 - 60 Hz 1/8 power
Operator - GR
LmtAVVoltage
LmtQPVoltage
Peak_21
AVG_21
QP_21
AV_21
LmtQPVoltage
Peak_21
AVG_21
QP_21
AV_21
Frequency
QP Level
QP Margin
QP Limit
AV Level
AV Margin
AV Limit
MHz dB(µV) dB dB dB(µV) dB dB
0.000
22.2
22.2 22 22.2 22.2 22
0.23 52.0
-10.4 62.4 46.5 -6.0
52.4
0.345 45.6 -13.5 59.1 41.7 -7.4
49.1
0.46 43.2
-13.5 56.7 37.9 -8.8
46.7
0.585 35.2 -20.8 56.0 18.8 -27.2 46.0
1.945 39.1 -16.9 56.0 26.9 -19.1 46.0
3.615 12.6 -43.4 56.0 1.8
1.945 39.1 -16.9 56.0 26.9 -19.1 46.0
3.615 12.6 -43.4 56.0 1.8
-44.2 46.0
4.475 32.4 -23.6 56.0 8.1
-37.9 46.0
7.905 37.0 -23.0 60.0 11.6 -38.4 50.0
8.37 45.7
8.37 45.7
-14.3 60.0 16.1 -33.9 50.0
9.055 39.1 -20.9 60.0 13.7 -36.3 50.0
Click on the first or last page to see other ES 150P (serv.man2) service manuals if exist.