JBL ES 150P (serv.man2) EMC - CB Certificate ▷ View online
mikes-testingpartners gmbh
File
No.
F31764-00-00HM
, page
12 of 31
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.3
5.2 Disturbance
power
For test instruments and accessories used see section 6 Part A 7.
5.2.1 Description of the test location
Test location:
Test location:
Shielded Room S7
5.2.2 Photo documentation of the test set-up
5.2.3 Test
result
Frequency range:
30 MHz - 300 MHz
Min. limit margin
>5 dB
The requirements are
FULFILLED.
Remarks:
For detailed results, please see the following page(s).
mikes-testingpartners gmbh
File
No.
F31764-00-00HM
, page
13 of 31
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.3
5.2.4 Test
protocol
Test point:
AC power line
Operation mode:
60 Hz 1/8 rated output power
Remarks: N/A
Date:
Date:
24. May 2007
Tested by:
Michael Hackl
Result: passed
30,100
33,0
21,0
1,0
34,0
22,0
45,0
35,0
-11,0
-13,0
31,500
31,0
20,0
0,9
31,9
20,9
45,1
35,1
-13,2
-14,2
Power
AV
[dBpW]
Dlimit AV
[dB]
Power
QP
[dBpW]
Dlimit QP
[dB]
Frequency
[MHz]
Reading
QP
[dBpW]
Correct.
[dB]
Limit AV
[dBpW]
Reading
AV
[dBpW]
Limit QP
[dBpW]
0
10
20
30
40
50
60
70
80
0
50
100
150
200
250
300
f [MHz]
dBpW
Limit QP (Frequency range: 30 - 300 MHz)
Limit AV (Frequency range: 30 - 300 MHz)
Power QP dBpW
Power AV dBpW
QP
AV
mikes-testingpartners gmbh
File
No.
F31764-00-00HM
, page
14 of 31
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.3
Test point:
Line in/LFE
Operation mode:
60 Hz 1/8 rated output power
Remarks: N/A
Date:
Date:
24. May 2007
Tested by:
Michael Hackl
Result: passed
31,000
34,0
23,0
1,0
35,0
24,0
45,0
35,0
-10,0
-11,0
50,500
34,0
22,0
0,6
34,6
22,6
45,8
35,8
-11,2
-13,2
Power
AV
[dBpW]
Dlimit AV
[dB]
Power
QP
[dBpW]
Dlimit QP
[dB]
Frequency
[MHz]
Reading
QP
[dBpW]
Correct.
[dB]
Limit AV
[dBpW]
Reading
AV
[dBpW]
Limit QP
[dBpW]
0
10
20
30
40
50
60
70
80
0
50
100
150
200
250
300
f [MHz]
dBpW
Limit QP (Frequency range: 30 - 300 MHz)
Limit AV (Frequency range: 30 - 300 MHz)
Power QP dBpW
Power AV dBpW
QP
AV
mikes-testingpartners gmbh
File
No.
F31764-00-00HM
, page
15 of 31
Ohmstrasse 2-4
x 94342 Strasskirchen
Tel.:+49(0)9424-94810
x Fax:+49(0)9424-9481240
Rev. No. 1.3
5.3 Harmonic
current
For test instruments and accessories used see section 6 Part H & Fl.
5.3.1 Description of the test location
Test location:
Test location:
AREA 1
5.3.2 Photo documentation of the test set-up
5.3.3 Test
result
The requirements are
FULFILLED.
Remarks:
For detailed results, please see the following page(s).
Click on the first or last page to see other ES 150P (serv.man2) service manuals if exist.