JBL E 150P EMC - CB Certificate ▷ View online
Page 5 of 47
Report No. 702268
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
Test item particulars
................................................. : Powered Subwoofer
Classification of installation and use........................... : -
Supply Connection ..................................................... : Mains plug
.................................................................................... :
.................................................................................... :
Possible test case verdicts:
- test case does not apply to the test object ................ : N/A (Not Applicable)
- test object does meet the requirement ...................... : P (Pass)
- test object does not meet the requirement................ : F (Fail)
Testing
........................................................................ :
Date of receipt of test item........................................... : 27 February 2007
Date (s) of performance of tests .................................. : 27 February – 21 March 2007
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a point is used as the decimal separator.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a point is used as the decimal separator.
General product information:
Powered Subwoofer
Powered Subwoofer
Page 6 of 47
Report No. 702268
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ................................: Class II
P
4
GENERAL CONDITIONS OF TESTS
4.1.4
Ventilation instructions require the use of the test
box
box
No N/A
5 MARKING
Comprehensible and easily discernible
P
Permanent durability against water and petroleum
spirit
spirit
P
5.1
a), b)
Identification, maker, model ...................................:
, E150P/230
P
c)
Class II symbol if applicable
P
d), e)
Rated supply voltage and symbol ..........................: AC 220-230V~
P
f)
Frequency if safety dependant
50/60Hz
P
g), h), i)
Rated current or power consumption ....................: 180W
P
5.2 a)
Earth terminal
N/A
b)
Hazardous live terminals
N/A
c)
Supply output terminals (other than mains)
N/A
5.3
Use of triangle with exclamation mark
In circuit diagram
P
5.4
Instructions for use
5.4.1
a)
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled with
liquid, etc.
or splashing. Warning concerning objects filled with
liquid, etc.
P
b)
Hazardous live terminals, instructions for wiring
N/A
c)
Instructions for replacing lithium battery
N/A
Instructions for modem if fitted
N/A
d)
Class I earth connection warning
N/A
e)
Instructions for multimedia system connection
N/A
f)
Special stability warning for fixed installation
N/A
g)
Batteries not exposed to heat/sun warning
N/A
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
Plug, text in instruction manual
provided.
provided.
P
Instructions for permanently connected equipment
N/A
Page 7 of 47
Report No. 702268
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation < 36 pA/kg (0.5 mR/h)
N/A
6.2
Laser radiation, emission limits to IEC 60825-1 ....:
N/A
Emission limits under fault conditions ....................:
N/A
7
HEATING UNDER NORMAL OPERATING CONDITIONS
(See appended table)
7.1
Temperature rises not exceeding specified values,
any single protective device defeated except those
of Cl. 7.1 a) and b)
any single protective device defeated except those
of Cl. 7.1 a) and b)
P
7.1.1
Temperature rise of accessible parts
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
P
7.1.4
Temperature rise of windings
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150
o
C
N/A
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
P
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
P
8.5
Class I equipment
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
Page 8 of 47
Report No. 702268
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
8.6
Class II equipment and Class II constructions within Class I equipment
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
P
Components bridging reinforced or double insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
Mains transformer
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
N/A
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
8.7
This sub-clause is void
-
8.8
Double Insulation: the Basic or Supplementary
insulation > 0.4 mm (mm) ......................................:
insulation > 0.4 mm (mm) ......................................:
Primary wires are double
insulated
insulated
P
Reinforced insulation > 0.4 mm (mm) ...................: Transformer
bobbin
P
Thin sheet insulation used inside the enclosure.
N/A
Basic or supplementary insulation, at least two
layers, each meeting 10.3 dielectric
layers, each meeting 10.3 dielectric
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3 dielectric
two of which meet 10.3 dielectric
N/A
Reinforced insulation, two layers each of which meet
10.3 dielectric
10.3 dielectric
N/A
Reinforced insulation, three layers any two which
meet 10.3 dielectric
meet 10.3 dielectric
N/A
8.9
Primary Wiring: Adequate insulation between
internal hazardous live conductors and accessible
parts
internal hazardous live conductors and accessible
parts
Applies to class I appliances
N/A
Secondary Wiring: Adequate insulation between
internal hazardous live parts and conductors
connected to accessible parts
internal hazardous live parts and conductors
connected to accessible parts
N/A
8.10 Class
II
Wiring:
(1) Primary: Double insulation between conductors
connected to the mains and accessible parts.
connected to the mains and accessible parts.
(2) Secondary: Double insulation between
conductors connected to accessible parts and the
mains
conductors connected to accessible parts and the
mains
Live wires are double insulated.
No secondary wire can come
into contact with live bare parts.
No secondary wire can come
into contact with live bare parts.
P