JBL E 150P EMC - CB Certificate ▷ View online
Page 21 of 47
Report No. 702268
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
20
RESISTANCE TO FIRE
20.1
Electrical components and mechanical parts
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined in
20.1 mounted on a board of flammability category of
V-1 to IEC 60695-11-10
20.1 mounted on a board of flammability category of
V-1 to IEC 60695-11-10
P
20.1.1
Electrical components meet the requirements of
Clause 14 or 20.1.4
Clause 14 or 20.1.4
P
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, not
contributing to the spread of fire
> 4 kV or leaving an internal fire enclosure, not
contributing to the spread of fire
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC 60707, unless used in a fire enclosure
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC 60707, unless used in a fire enclosure
PCB: V-0
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
N/A
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
P
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N/A
Apparatus with voltages > 4 kV under normal
conditions, and distances to enclosure exceed
those specified by Table 21, HB40 min enclosure
conditions, and distances to enclosure exceed
those specified by Table 21, HB40 min enclosure
N/A
20.2
Fire enclosure
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
N/A
20.2.2
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A
Page 22 of 47
Report No. 702268
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
A
ANNEX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
ANNEX B, APPARATUS TO BE CONNECTED TO THE TELECOMMUNICATION
NETWORKS
NETWORKS
Complies with IEC 62151 clause 1
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N/A
Complies with IEC 62151 clause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
L
ANNEX L, ELECTRONIC FLASH APPARATUS FOR PHOTOGRAPHIC
PURPOSES
PURPOSES
L.5.4
Battery chargers and supply apparatus marked with
model number.
model number.
N/A
L7.1.5 Lithium
batteries:
temperature rise (Normal)
N/A
L.9.1.1
Flash synchroniser teminals not hazardous live.
N/A
L.11.2.6
Lithium batteries: temperature rise (Fault).
N/A
L.14.6.6
Peak surge current and rated mains current not to
exceed mains switch current rating
exceed mains switch current rating
N/A
Page 23 of 47
Report No. 702268
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
7.1
TABLE: temperature rise measurements: Conditions
P
Power consumption in the OFF/Stand-by mode of
the functional switch (W)………..….:…………....:
the functional switch (W)………..….:…………....:
0 W / No stand-by mode
P
Cond.
Un (V)
Hz
In (A)
Pn (W)
V out
Pout (W)
Operating Condition
1
253
50
0.43
34
8.5
18
1/8 of max. non-clipping output
power (pink noise)
power (pink noise)
Loudspeaker impedance (Ω) .................................:
4Ω rated (5.9Ω measured)
—
Several
loudspeaker
systems
—
Marking of loudspeaker terminals
—
—
Temperature Rise dT of Part
dT (K)
Limit max dT (K)
Test Condition No.
No 1
No ___
No ___
Iron core
60
- -
-
Supply wiring insulation
30
- -
60 (50)
PCB
35
- -
85 (75)
Electrolytic capacitor C6
33
- -
(85 ºC -35=) 50
Inside plastic enclosure
17
- -
60 (50)
Rear enclosure (plastic)
26
- -
60 (50)
Top of enclosure (wood)
6
- -
60 (50)
Knobs (plastic)
<26
- -
50 (40)
The limit values in parenthesis are the limit values for tropical climate.
Winding temperature rise measurements
Ambient temperature t1 (
o
C) ............................
Ambient temperature t2 (
o
C) ............................
23
23
-
-
-
-
—
—
Temperature rise dT of winding:
dT = (R
dT = (R
2
– R
1
) x (234.5 + t1) – (t2 – t1)
R
1
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit
maxK)
Insulation class
Primary
14.058 17.974
71
85 (75)
-
Secondary
1.2402 1.5374
62
85 (75)
-
Page 24 of 47
Report No. 702268
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
9.1
Shock Hazard
P
Under normal operating conditions: > 35Vpk ac / 60V dc
Notes: Reference Annex D
Notes: Reference Annex D
-
CLASS I: (single phase)
AC
DC
U1: Vpk
mA rms
U1: V
mA
U2: Vpk
mA rms
CLASS II: (single phase)
U1:
0.01Vpk
mA rms
U1: V
mA
U2:
0.016Vpk
mA rms
10.3
TABLE: Insulation Resistance Measurements
P
Insulation resistance R between:
R (MΩ)
Min
required R
(MΩ)
Between mains poles (primary fuse disconnected)
>10
≥ 2
Between parts separated by basic or supplementary insulation
>10
≥ 2
Between parts separated by double or reinforced insulation
>10
≥ 4
10.3
TABLE: Electric Strength Measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120 peak
No
Between parts separated by basic or supplementary insulation
2120 peak
No
Between parts separated by double or reinforced insulation
4240 peak
No
Click on the first or last page to see other E 150P service manuals if exist.