JBL E 150P EMC - CB Certificate ▷ View online
Page 9 of 47
Report No. 702268
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
8.11
Detaching of wires
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
No risk of any wire becoming
detached.
detached.
N/A
Vibration test carried out ........................................: No need, see above
N/A
8.12
This sub-clause is void
-
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (pull test 50 N for
10 s)
10 s)
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges (2N force)
due to hot parts or sharp edges (2N force)
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
8.19.1
Disconnect device
Mains plug
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
N/A
8.19.2
Mains switch ON indication
N/A
8.20 Switch
not
fitted
in the mains cord
N/A
8.21
Bridging components comply with clause 14
N/A
8.22
Test of non-separable thin sheet material
N/A
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
N/A
9.1.1.1 a) Determination of Hazardous Live parts
U1: 7mV peak
U2: 3mV peak
P
b) Touch current measured from terminal devices
using the network in annex D ................................:
P
c) Discharge not exceeding 45 μC
N/A
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
P
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
N/A
Page 10 of 47
Report No. 702268
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
N/A
9.1.4
Terminal devices - within 25mm tested with
1 mm x 20 mm test pin (10 N); test probe D of IEC
61032
1 mm x 20 mm test pin (10 N); test probe D of IEC
61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
N/A
If C is not greater than 0.1 μF no test needed
CXAC1=0.1µF
P
9.1.7
Enclosure sufficiently resistant to external force
a)
Test probe 11 of IEC 61032 for 10 s (50 N)
P
b)
Test hook of fig. 4 for 10 s (20 N)
P
c)
Conductive enclosure: 30 mm diameter test tool for
5 s (100 or 250 N) ..................................................:
5 s (100 or 250 N) ..................................................:
N/A
9.2
No hazard 2s after removing a cover by hand
N/A
10 INSULATION
REQUIREMENTS
10.1 Insulation
resistance
(MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................:
insulation ................................................................:
N/A
10.2
Humidity treatment 48 h or 120 h ..........................: 48h and 120h (see also
Differences for Singapore)
P
10.3
Insulation resistance and dielectric strength
between mains terminals
between mains terminals
P
Insulation resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
BASIC or SUPPLEMENTARY insulation (Class 1)
P
Insulation resistance across REINFORCED
insulation (Class II)
insulation (Class II)
P
11 FAULT
CONDITIONS
11.1
No shock hazard under fault condition
P
11.2 Heating
under
fault
condition
P
No hazard from softening solder
P
No flaming more than 10s
P
Soldered terminations not used as protective
mechanism
mechanism
P
Page 11 of 47
Report No. 702268
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
11.2.1 Measurement
of
temperature
rises
P
11.2.2
Temperature rise of accessible parts
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm²
to 20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm²
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
N/A
11.2.5
Temperature rise of windings
P
11.2.6 Temperature
rise
of
parts not subject to the limits of
11.2.1 to 11.2.5 Table 3 e) "Other Parts"
P
12 MECHANICAL
STRENGTH
12.1.1
Bump test where mass >7 kg
P
12.1.2
Vibration test (portable, metal, musical amps)
No connection or part that might
impair safety can become loose
impair safety can become loose
P
12.1.3
Impact hammer test
P
Steel ball test (for non-ventilated solid areas)
P
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg
N/A
12.1.5
Thermoplastic enclosures stress relief test
P
12.2
Fixing of knobs, push buttons, keys and levers
P
12.3
Remote controls with hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
N/A
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A
Page 12 of 47
Report No. 702268
IEC
60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
13
CLEARANCE AND CREEPAGE DISTANCES
(See appended table 13)
13.1
Clearances in accordance with 13.3
P
Creepage distances in accordance with 13.4
P
13.2
Determination of operating voltage
P
13.3
Clearances
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
Circuits not conductively
connected to the mains cannot
cause any shock hazard
connected to the mains cannot
cause any shock hazard
N/A
13.3.4
Measurement of transient voltages
N/A
13.4
Creepage distances
Creepage distances greater than table 11 minima
P
13.5
Printed boards
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N/A
13.6 Conductive
parts
along
uncemented
joints
clearances and creepage distances comply with
13.3 and 13.4
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N/A
Click on the first or last page to see other E 150P service manuals if exist.