JBL DUET III EMC - CB Certificate ▷ View online
- Page 5 of 5 -
www.nemko.com
Report No. 116366
5.1.8.3
Equipment intended to receive
telecommunication ringing signals is required to
comply with a special touch current
measurement tests.
telecommunication ringing signals is required to
comply with a special touch current
measurement tests.
No TNV circuitry.
N/A
6.2.1
Enamel coating on winding wire not considered
electrical separation unless subjected to special
investigation.
electrical separation unless subjected to special
investigation.
No TNV circuitry.
N/A
6.4
Equipment intended for connection to
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
No TNV circuitry.
N/A
6.5
Equipment connected to a telecommunications
network and supplied with an earphone intended
to be held against, or in the ear is required to
comply with special acoustic pressure tests.
network and supplied with an earphone intended
to be held against, or in the ear is required to
comply with special acoustic pressure tests.
No TNV circuitry.
N/A
M.2
Continuous ringing signals up to 16 mA only are
permitted if the equipment is subjected to special
installation and performance restrictions.
permitted if the equipment is subjected to special
installation and performance restrictions.
No TNV circuitry.
N/A
- Page 1 of 1 -
www.nemko.com
Report No. 116366
ATTACHMENT: ISRAELI DIFFERENCES
to IEC 60950-1 (ed.1)
Clause
Requirements – Test
Result – Remark
Verdict
1.7.0
Marking and Instructions
The package of the equipment shall be marked in
Hebrew, and shall include:
- The name of the product,
- The name of the manufacturer,
- The country of production,
- The name and the address of the importer.
The marking shall be on a rectangular label (of at
least 52mm x 24mm). The letters height should be
at least 2mm. The color of the label shall be in
contrast to the color of the package.
The package of the equipment shall be marked in
Hebrew, and shall include:
- The name of the product,
- The name of the manufacturer,
- The country of production,
- The name and the address of the importer.
The marking shall be on a rectangular label (of at
least 52mm x 24mm). The letters height should be
at least 2mm. The color of the label shall be in
contrast to the color of the package.
Must be considered before
marketed in Israel.
marketed in Israel.
—
1.7.12 Language
All instructions and warnings concerning safety
should be in the Hebrew language as well.
Must be considered before
marketed in Israel.
marketed in Israel.
—
2.101 EMC
The equipment shall comply with SI 961 part 6
(CISPR 22 + 24).
Compliance with EMC must be
considered before marketed in
Israel.
considered before marketed in
Israel.
N/A
3.2.1.1
Connection to an a.c. mains supply
Additional note:
In Israel the mains supply plug shall comply with
Israeli standard SI 32.
Additional note:
In Israel the mains supply plug shall comply with
Israeli standard SI 32.
Class III equipment supplied by a
separately certified adaptor.
(refer to summary of testing)
separately certified adaptor.
(refer to summary of testing)
N/A
- Page 1 of 1 -
www.nemko.com
Report No. 116366
ATTACHMENT: CHINESE DIFFERENCES
Test results according to CB BULLETIN No. 112A, December 2006
Clause
Requirement - Test
Result - Remark
Verdict
1.4.5
1.4.5 second paragraph replaced by:
If the equipment is intended for direct
connection to an AC MAINS SUPPLY, the
tolerances on RATED VOLTAGE shall be
taken as +10 % and –10 %,unless:
If the equipment is intended for direct
connection to an AC MAINS SUPPLY, the
tolerances on RATED VOLTAGE shall be
taken as +10 % and –10 %,unless:
Class III equipment supplied by
a separately certified adaptor.
(refer to summary of testing)
a separately certified adaptor.
(refer to summary of testing)
N/A
1.7.1
1.7.1 fifth paragraph replaced by:
When single rated voltage is given, it should
be marked 220 V; when a rating range is
given, the voltage range shall have a
hyphen (-) between the minimum and
maximum RATED VOLTAGES and should
cover 220 V; When multiple RATED
VOLTAGES or RATED VOLTAGE RANGES
are given, they shall be separated by a solidus
(/) and one of them must be 220 V and also
factory default setting should be 220 V.
RATED FREQUENCY or RATED
FREQUENCY RANGE should be 50Hz or
cover 50Hz, unless the equipment is designed
for d.c.
When single rated voltage is given, it should
be marked 220 V; when a rating range is
given, the voltage range shall have a
hyphen (-) between the minimum and
maximum RATED VOLTAGES and should
cover 220 V; When multiple RATED
VOLTAGES or RATED VOLTAGE RANGES
are given, they shall be separated by a solidus
(/) and one of them must be 220 V and also
factory default setting should be 220 V.
RATED FREQUENCY or RATED
FREQUENCY RANGE should be 50Hz or
cover 50Hz, unless the equipment is designed
for d.c.
only;
Class III equipment supplied by
a separately certified adaptor.
a separately certified adaptor.
Additional marking showed on
equipment, ”Power 1200mA
18Vdc”
equipment, ”Power 1200mA
18Vdc”
N/A
1.7.12
1.7.12 replaced by:
Instructions and equipment marking related to
safety shall be written in simplified Chinese in
which the equipment is to be installed.
Instructions and equipment marking related to
safety shall be written in simplified Chinese in
which the equipment is to be installed.
Must be considered before
marketed in China.
marketed in China.
—
3.2.1
3.2.1 Add at the end of the first paragraph:
Plugs of apparatus which are intended for the
connection of the mains supply should comply
with requirements of GB1002.
Plugs of apparatus which are intended for the
connection of the mains supply should comply
with requirements of GB1002.
Class III equipment supplied by
a separately certified adaptor.
(refer to summary of testing)
a separately certified adaptor.
(refer to summary of testing)
N/A
- Page 1 of 6 -
www.nemko.com
Report No. 116366
ATTACHMENT: JAPANESE DIFFERENCES
Test results according to CB BULLETIN No. 112A, December 2006
Clause
Requirement - Test
Result - Remark
Verdict
1.2
Addition:
Add the following terms.
Equipment, Class 0I 1.2.4.101
Material, VTM 1.2.12.101
Material, VTM 1.2.12.101
Considered. P
1.2.4.101
Addition:
CLASS 0I EQUIPMENT: Equipment where protection
against electric shock is achieved by:
against electric shock is achieved by:
a) using BASIC INSULATION, and
b) providing a means of connecting to the protective
earthing conductor in the building wiring those
conductive parts that are otherwise capable of
assuming HAZARDOUS VOLTAGES if the BASIC
INSULATION fails, and
earthing conductor in the building wiring those
conductive parts that are otherwise capable of
assuming HAZARDOUS VOLTAGES if the BASIC
INSULATION fails, and
c) using a supply cord without earthing conductor and
a plug without earthing wire although the equipment
has externally an earth terminal or a lead wire for
earthing.
a plug without earthing wire although the equipment
has externally an earth terminal or a lead wire for
earthing.
Equipment provided with a cord set having a two-pin
type plug with a lead wire for earthing is also regarded
as Class 0I.
type plug with a lead wire for earthing is also regarded
as Class 0I.
NOTE – Class 0I equipment may have a part
constructed with Double Insulation or Reinforced
Insulation as well as an operating part as SELV circuit.
constructed with Double Insulation or Reinforced
Insulation as well as an operating part as SELV circuit.
Class III equipment
supplied by a separately
certified adaptor. (refer
to summary of testing)
supplied by a separately
certified adaptor. (refer
to summary of testing)
N/A
1.2.12.1
Replacement:
FLAMMABILITY CLASSIFICATION OF MATERIALS:
The recognition of the burning behaviour of materials
and their ability to extinguish if ignited. Materials are
classified as in 1.2.12.2 to 1.2.12.9, and 1.2.12.101
when tested in accordance with annex A.
The recognition of the burning behaviour of materials
and their ability to extinguish if ignited. Materials are
classified as in 1.2.12.2 to 1.2.12.9, and 1.2.12.101
when tested in accordance with annex A.
NOTE 1 - When applying the requirements in this
standard, HF-1 CLASS FOAMED MATERIALS are
regarded as better than those of CLASS HF-2, and
HF-2 better than HBF.
standard, HF-1 CLASS FOAMED MATERIALS are
regarded as better than those of CLASS HF-2, and
HF-2 better than HBF.
NOTE 2 - Similarly, other MATERIALS, including rigid
(engineering structural) foam of CLASSES 5V or V-0
are regarded as better than those of CLASS V-1, V-1
better than V-2, and V-2 better than HB.
(engineering structural) foam of CLASSES 5V or V-0
are regarded as better than those of CLASS V-1, V-1
better than V-2, and V-2 better than HB.
NOTE 3 - Similarly, for thin MATERIALS, VTM-0 Class
materials are regarded as better than those of VTM-1
Class, and VTM-1 better than VTM-2.
materials are regarded as better than those of VTM-1
Class, and VTM-1 better than VTM-2.
Considered. P