Ident. Nr.: 
114383 
Date:  
2008-11-09 
 
114383 EMC TRF.doc 
page 25 of 38 
9.5 Table 
9.5.1 Table 008 
 
 
Frequency Range 
(MHz) 
 
80-1000MHz 
Field Strength 
(V/m) 
3V/m  1kHz 80%AM 
Steps  
(%) 
1% 
Dwell time 
1 s 
Polarization 
Horizontal 
Vertical 
Front Pass 
Pass 
Rear Pass 
Pass 
Left Pass 
Pass 
Right Pass 
Pass 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Ident. Nr.: 
114383 
Date:  
2008-11-09 
 
114383 EMC TRF.doc 
page 26 of 38 
10 Electrical 
Fast 
Transients/Bursts Immunity 
10.1 Standard 
Basic standard 
EN 61000-4-4:2004 
Date of testing 
2008-10-29 
Performance criteria: 
10.2 Measurement equipment 
 
Equipment 
Last Calibration
Type 
 
Serial No
.  
Manufacturer 
  EFT simulator 
February 25, 
2008 
NSG2025-1 SB2556  SCHNAFFNER 
10.3 Test set-up 
See annex B  
The EUT is placed on a table that is 0.8meter height. A ground reference plane is placed on the table, 
and uses a 0.1m insulation between the EUT and ground reference plane. 
The minimum area of the ground reference plane is 1m*1m, and projected beyond the EUT by at least 
0.1m on all sides. 
Test on power supply ports: 
The duration time of each test sequential was 1 minute. 
The length of the signal and power lines between the coupling device and the EUT is 0.5m. 
10.4 Test results 
Mode 
Table 
Remarks 
Result 
TM1 009 
±
1KV  
Tr/Th: 5/50ns 
Repetition frequency:5kHz 
Test to input a.c. power port 
(Signal port cable is less than 3m) 
Pass   
10.5 Table 
10.5.1 Table 009 
 
Injected Line 
Voltage 
(kV) 
Duration time 
(s) 
Injected Method 
Result 
+1 60 
Direct 
Pass 
-1 60 
Direct 
Pass 
+1 60 
Direct 
Pass 
-1 60 
Direct 
Pass 
+1 60 
Direct 
Pass 
L,N 
-1 60 
Direct 
Pass 
Ident. Nr.: 
114383 
Date:  
2008-11-09 
 
114383 EMC TRF.doc 
page 27 of 38 
11 Surge Immunity 
11.1 Standard 
Basic standard 
EN 61000-4-5:2006 
Date of testing 
2008-10-29 
Performance criteria: 
11.2 Measurement equipment 
 
Equipment 
Last Calibration
Type 
 
Serial No
.  
Manufacturer 
  Immunity simulator 
February 25, 
2008 
UCS5500M4 
SB3070 
EMTEST 
  Three Phase Coupling 
Network 
February 25, 
2008 
CNI5036 SB3070/01 
EMTEST 
11.3 Test set-up 
See annex B  
The EUT and the auxiliary equipment were placed on a table of 0.8m heights above a metal ground 
reference plane. The size of ground plane is greater than 1m×1m and project beyond the EUT by at 
least 0.1m on all sides. The ground plane is connected to the protective earth. The length of power 
cord between the coupling device and the EUT was less than 2 meters (provided by the 
manufacturer).  
The surge noise shall be applied synchronized to the voltage phase at 0
o
,90
o
,180
o
,270
o
 and the peak 
value of the a.c. voltage wave. (Positive and negative). 
Each of Line-Line is impressed with a sequence of five surge voltages with interval of 1 min. 
11.4 Test results 
Mode 
Table 
Remarks 
Result 
TM1 010 
Tr/Th 1,2/50(8/20)
 μs 
Line to line 1kV  
Line to Gnd 2kV 
Repetition frequency 5kHz  
Test to input a.c. power port 
(Signal port can not  directly 
connect to outdoor cable)
 
Pass   
 
11.5 Table 
11.5.1 Table 010 
 
Injected 
Line 
Wave 
Form 
Voltage
(kV) 
Phase 
Number of 
Pulse 
Interval 
time 
Result
+1 
0
o
,90
o
, 180
o
,270
20 60s 
Pass 
L-N 
1.2/50μs 
-1 
0
o
,90
o
, 180
o
,270
20 60s 
Pass 
Ident. Nr.: 
114383 
Date:  
2008-11-09 
 
114383 EMC TRF.doc 
page 28 of 38 
12 Conducted 
Immunity 
12.1 Standard 
Basic standard 
EN 61000-4-6:1996/A1:2001 
Date of testing 
2008-10-29 
Performance criteria: 
12.2 Measurement equipment 
 
Equipment 
Last Calibration
Type 
 
Serial No
.  
Manufacturer 
  CW sine Generator  
January 25, 
2008 
CWS500 SB2605
 
EMTEST 
  CDN January 
25, 
2008 
CDN-M2 SB2605/01
 
EMTEST 
 
12.3 Test set-up 
See annex B  
The EUT are placed on a table that is 0.8 meter height, and a Ground reference plane on the table, 
EUT are placed upon table and use a 10cm insulation between the EUT and Ground reference plane. 
For Input DC and AC Power Ports: The EUT is connected to the power mains through a coupling and 
decoupling networks for power supply lines. And directly couples the disturbances signal into EUT. 
 
12.4 Test results 
Mode 
Table 
Remarks 
Result 
TM1 011 1. Field Strength :3V(unmodulated,r.m.s) 
2. Test Signal: AM 80% Modulated with 1kHz 
3. Scanning Frequency :0.15MHz – 80MHz 
4. Source impedance 150Ω 
Pass   
 
12.5 Table 
12.5.1 Table 011 
 
Frequency Range 
(MHz) 
Injecteded Position
Strength 
Result 
0.15MHz ~ 80MHz 
AC Lines 
3V(r.m.s, Unmodulated)
Pass 
Dwell time:1s; Steps: 1% 
 
 
 
 
 
 
 
 
 
 