DOWNLOAD JBL DUET II (serv.man5) Service Manual ↓ Size: 1.47 MB | Pages: 38 in PDF or view online for FREE

Model
DUET II (serv.man5)
Pages
38
Size
1.47 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
duet-ii-sm5.pdf
Date

JBL DUET II (serv.man5) EMC - CB Certificate ▷ View online

Ident. Nr.: 
114383 
Date:  
2008-11-09 
 
114383 EMC TRF.doc 
page 13 of 38 
Measurement of radiated emission 
5.1 Standards 
Product or product family standard 
EN 55022:2006 
Limit class 
Class B 
Basic standard 
CISPR 16 
Date of testing 
2008-10-28 
5.2 Measurement equipment 
 
Equipment 
Last Calibration 
Type 
 
Serial No
Manufacturer 
EMI Test Receiver  
January 25, 2008 ESI26 
SB3436 
Rohde & Schwarz 
Bilog Antenna 
January 25, 2008 CBL6112B SB3440 
Chase 
 
Semi-anechoic 
chamber 
January 25, 2008 9X6X6 
SB3450/01 Albatross 
Projects 
 
5.3 Test set-up 
 
The EUT has been tested according to the above-mentioned standard, as following: 
The EUT was placed on the top of an insulating table 0.8 meters above the ground at a semi-
anechoic chamber. The table was rotated 360 degrees to determine the position of the highest 
radiation. The EUT was set 3 meters away from the interference-receiving antenna, which was 
mounted on the top of a variable-height antenna tower. The antenna is a broadband antenna, and its 
height is varied from 1 to 4 meter above the ground to determine the maximum value of the field 
strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement. 
For each suspected emission, the EUT was arranged to its worst case and then the antenna was 
tuned to the heights from 1 to 4 meters and the ratable table was turned from 0 degrees to 360 
degrees to find the maximum reading. The test-receiver system was set to Peak Detector Function 
and Specified Bandwidth with Maximum Hold Mode. 
If more details are necessary, e.g. because of wiring or auxiliary equipment, annex B with a photo or 
a rough figure of the test set-up is attached. 
The test has been performed as following: 
1)  Preview test; Peak; IF BW=120kHz, VBW=300kHz, Antenna: from 1 to 4m Turntable 0-360deg 
2)  Find frequencies with maximum emission: 
Acceptance-analysis: Limit minus 10 dB 
Peak-reduction: 10Peaks frequency range 30 MHz - 1000 MHz 
3)  Final test; Quasi-Peak; measuring time 1 s; at frequencies from step 2); Search maximum: vary 
turntable and antenna position to find the maximum readings 
4)  If there are more than 10 peaks within the 10 dB margin a manual test with all settings is 
necessary to find the maximum readings. 
The EUT ‘s internal freq is lower than 108MHz,so RE test above 1GHz is not necessary . 
5.4 Test result  
Mode 
Diagram   
Remarks 
Result 
TM1 
Diagram
  004 
H and V 
Pass 
Remark  The emissions don’t show in table when too low against the limits, the test curves are 
shown as below. 
Ident. Nr.: 
114383 
Date:  
2008-11-09 
 
114383 EMC TRF.doc 
page 14 of 38 
5.5  Diagrams and tables 
5.5.1  Diagram 004   
EUT:                 Duet II 
Manufacturer   :      
Operating Condition: Connect to PC (Play MP3) 
Test Specification:  Horizontal & Vertical 
Comment:             AC 230/50Hz 
 
             
Ident. Nr.: 
114383 
Date:  
2008-11-09 
 
114383 EMC TRF.doc 
page 15 of 38 
6 Harmonic 
current 
6.1 Standard 
Basic standard 
EN 61000-3-2:2006 
Date of testing 
2008-10-29 
6.2 Measurement equipment 
 
Equipment 
Last Calibration 
Type 
 
Serial No
Manufacturer
Power 
February 20, 2008  5001ix-CTS-400 
SB2588 
CI 
Three Phase Harmonic 
flicker test system 
February 20, 2008  PACS-3 
SB2588/01  CI 
Power 
February 20, 2008  5001ix-CTS-400-NO SB2588/02  CI 
Power 
February 20, 2008  5001ix-CTS-400-NO SB2588/03  CI 
6.3 Test set-up 
See annexe B   
6.4  Classification of EUT 
Devices with an active input power 
of P <75 W 
 
 
Balanced three-phase equipment and all other 
equipment, expect that stated in one of the 
following classes 
Class A  
 
 
Portable tools 
Class B  
 
Lightning equipment, including dimming devices 
Class C  
 
Equipment having an input current with a "special 
wave shape" as defined in figure 1 in the 
standard and an active input power, P 
 600 W 
and motor driven with phase angle control 
Class D  
 
The power cord of the EUT is connected to the output of the test systems , Turn on the power of the 
EUT and use the test system to test the harmonic current level.Observation time: 150s 
If Harmonic current less than 0.6% of the input current measured under the test condition ,or less 
than 5mA, then whichever is greater,are disregarded. 
Ident. Nr.: 
114383 
Date:  
2008-11-09 
 
114383 EMC TRF.doc 
page 16 of 38 
6.5 Test results 
Mode 
Table 
Remarks 
Power 
Result 
TM1 005 
230VAC 
50Hz 
8.5W 
No limit * 
*) 
For devices with a rated power of 75 W or less, not being lighting equipment, no limit values are effective.
(EN61000-3-2) 
**) 
For professionally used devices with a total rated power exceeding 1 kW no limit values are effective. 
(EN61000-3-2) 
 
 
6.6 Table 
6.6.1  Table  005  
Harmonics – Class-A per Ed. 3.0 (2006)(Run time) 
 
EUT: Duet II 
Tested by: Test Operator 
Start time: 3:51:49 PM 
End time: 3:54:40 PM 
Test duration (min): 2.5 
Data file name: H-000849.cts_data 
Comment: Connect to PC(Play MP3) 
Customer: Customer 
 
Test Result: Pass          Source qualification: Normal 
 
Current & voltage waveforms 
  
 
-0.9
-0.6
-0.3
0.0
0.3
0.6
0.9
-300
-200
-100
0
100
200
300
  
Current (Amps)
Voltage (Volts)
 
Limits 
 
Page of 38
Display