JBL DUET II (serv.man5) EMC - CB Certificate ▷ View online
Ident. Nr.:
114383
Date:
2008-11-09
114383 EMC TRF.doc
page 17 of 38
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Current RMS(Amps)
Harmonic #
4
8
12
16
20
24
28
32
36
40
Test result: Pass Worst harmonic was #19 with 17.71% of the limit.
Ident. Nr.:
114383
Date:
2008-11-09
114383 EMC TRF.doc
page 18 of 38
Current Test Result Summary (Run time)
EUT: Duet II
Tested by: Test Operator
Start time: 3:51:49 PM
End time: 3:54:40 PM
Test duration (min): 2.5
Data file name: H-000849.cts_data
Comment: Connect to PC(Play MP3)
Customer: Customer
Test Result: Pass Source qualification: Normal
THC(A): 0.10 I-THD(%): 214.22 POHC(A): 0.037 POHC Limit(A): 0.251
Highest parameter values during test:
Customer: Customer
Test Result: Pass Source qualification: Normal
THC(A): 0.10 I-THD(%): 214.22 POHC(A): 0.037 POHC Limit(A): 0.251
Highest parameter values during test:
V_RMS (Volts): 230.06
Frequency(Hz): 50.00
I_Peak (Amps): 0.671
I_RMS (Amps): 0.121
I_Fund (Amps): 0.046
Crest Factor:
5.589
Power (Watts): 8.5
Power Factor:
0.307
Harm# Harms(avg) 100%Limit %of
Limit Harms(max) 150%Limit %of
Limit Status
2 0.002 1.080 0.0
0.004 1.620 0.24
Pass
3 0.036 2.300 1.6
0.038 3.450 1.09
Pass
4 0.002 0.430 0.0
0.004 0.645 0.65
Pass
5 0.035 1.140 3.1
0.035 1.710 2.06
Pass
6 0.002 0.300 0.0
0.004 0.450 0.79
Pass
7 0.034 0.770 4.4
0.034 1.155 2.96
Pass
8 0.002 0.230 0.0
0.004 0.345 1.04
Pass
9 0.032 0.400 8.0
0.032 0.600 5.39
Pass
10 0.002 0.184 0.0
0.004 0.276 1.34
Pass
11 0.030 0.330 9.2
0.030 0.495 6.15
Pass
12 0.002 0.153 0.0
0.003 0.230 1.51
Pass
13 0.028 0.210 13.4
0.028 0.315 8.96
Pass
14 0.002 0.131 0.0
0.004 0.197 1.82
Pass
15 0.026 0.150 17.2
0.026 0.225 11.51
Pass
16 0.002 0.115 0.0
0.003 0.173 1.99
Pass
17 0.023 0.132 17.7
0.024 0.199 11.83
Pass
18 0.002 0.102 0.0
0.003 0.153 2.21
Pass
19 0.021 0.118 17.7
0.021 0.178 11.86
Pass
20 0.002 0.092 0.0
0.003 0.138 2.35
Pass
21 0.019 0.107 17.4
0.019 0.161 11.65
Pass
22 0.002 0.084 0.0
0.003 0.125 2.48
Pass
23 0.016 0.098 16.8
0.017 0.147 11.30
Pass
24 0.002 0.077 0.0
0.003 0.115 2.58
Pass
25 0.014 0.090 15.9
0.015 0.135 10.74
Pass
26 0.002 0.071 0.0
0.003 0.106 2.68
Pass
27 0.013 0.083 15.0
0.013 0.125 10.16
Pass
28 0.001 0.066 0.0
0.003 0.099 2.74
Pass
29 0.011 0.078 14.0
0.011 0.116 9.49
Pass
30 0.002 0.061 0.0
0.003 0.092 2.88
Pass
31 0.009 0.073 13.0
0.010 0.109 8.78
Pass
32 0.001 0.058 0.0
0.002 0.086 2.73
Pass
33 0.008 0.068 11.9
0.008 0.102 8.13
Pass
34 0.001 0.054 0.0
0.002 0.081 2.67
Pass
35 0.007 0.064 10.9
0.007 0.096 7.45
Pass
36 0.001 0.051 0.0
0.002 0.077 2.51
Pass
37 0.006 0.061 9.9
0.006 0.091 6.79
Pass
38 0.001 0.048 0.0
0.002 0.073 2.43
Pass
39 0.005 0.058 8.9
0.005 0.087 6.10
Pass
40 0.001 0.046 0.0
0.002 0.069 2.33
Pass
Ident. Nr.:
114383
Date:
2008-11-09
114383 EMC TRF.doc
page 19 of 38
Voltage Source Verification Data (Run time)
EUT: Duet II
Tested by: Test Operator
Start time: 3:51:49 PM
End time: 3:54:40 PM
Test duration (min): 2.5
Data file name: H-000849.cts_data
Comment: Connect to PC(Play MP3)
Customer: Customer
Test Result: Pass Source qualification: Normal
Highest parameter values during test:
Customer: Customer
Test Result: Pass Source qualification: Normal
Highest parameter values during test:
Voltage (Vrms): 230.06
Frequency(Hz): 50.00
I_Peak (Amps): 0.671
I_RMS (Amps): 0.121
I_Fund (Amps): 0.046
Crest Factor:
5.589
Power (Watts): 8.5
Power Factor:
0.307
Harm# Harmonics
V-rms Limit
V-rms %
of
Limit Status
2
0.135
0.460
29.28
OK
3
0.471
2.070
22.73
OK
4
0.092
0.460
19.90
OK
5
0.024
0.920
2.60
OK
6
0.066
0.460
14.28
OK
7
0.041
0.690
5.88
OK
8
0.047
0.460
10.20
OK
9
0.023
0.460
5.04
OK
10
0.032
0.460
6.91
OK
11
0.030
0.230
13.05
OK
12
0.012
0.230
5.35
OK
13
0.015
0.230
6.64
OK
14
0.015
0.230
6.51
OK
15
0.024
0.230
10.34
OK
16
0.015
0.230
6.50
OK
17
0.016
0.230
7.11
OK
18
0.016
0.230
6.92
OK
19
0.025
0.230
10.70
OK
20
0.019
0.230
8.15
OK
21
0.013
0.230
5.60
OK
22
0.010
0.230
4.18
OK
23
0.024
0.230
10.57
OK
24
0.005
0.230
2.01
OK
25
0.011
0.230
4.93
OK
26
0.012
0.230
5.09
OK
27
0.021
0.230
9.05
OK
28
0.006
0.230
2.80
OK
29
0.012
0.230
5.16
OK
30
0.009
0.230
4.10
OK
31
0.016
0.230
7.00
OK
32
0.006
0.230
2.45
OK
33
0.010
0.230
4.14
OK
34
0.005
0.230
2.17
OK
35
0.012
0.230
5.16
OK
36
0.004
0.230
1.54
OK
37
0.010
0.230
4.30
OK
38
0.005
0.230
2.14
OK
39
0.010
0.230
4.38
OK
40
0.009
0.230
4.07
OK
Ident. Nr.:
114383
Date:
2008-11-09
114383 EMC TRF.doc
page 20 of 38
7
Voltage fluctuations and flicker
7.1 Standard
Basic standard
EN 61000-3-3:1995+A1:2001+A2:2005
Date of testing
2008-10-29
7.2 Measurement equipment
Equipment
Last Calibration
Type
Serial No
.
Manufacturer
Power
February 20, 2008
5001ix-CTS-400
SB2588
CI
Three Phase
Harmonic flicker
test system
test system
February 20, 2008
PACS-3
SB2588/01
CI
Power
February 20, 2008
5001ix-CTS-400-NO SB2588/02
CI
Power
February 20, 2008
5001ix-CTS-400-NO SB2588/03
CI
7.3 Test set-up
See annex B
The following limits apply:
-
The following limits apply:
-
the value of Pst shall not be greater than 1.0;
-
the value of Plt shall not be greater than 0.65;
-
the value of d(t) during a voltage change shall not exceed 3.3 % for more than 500 ms;
-
the relative steady-state voltage change, dc, shall not exceed 3.3 %;
-
the maximum relative voltage change, dmax, shall not exceed;
a) 4 % without additional conditions;
b) 6 % for equipment which is:
-
b) 6 % for equipment which is:
-
switched manually, or
-
switched automatically more frequently than twice per day, and also has either a delayed restart (the
delay being not less than a few tens of seconds), or manual restart,after a power supply interruption.
Note:The cycling frequency will be further limited by the Pst and Plt limit. For example: a dmax of 6%
producing a rectangular voltage change characteristic twice per hour will give a P1t of about 0.65.
c) 7 % for equipment which is:
-
Note:The cycling frequency will be further limited by the Pst and Plt limit. For example: a dmax of 6%
producing a rectangular voltage change characteristic twice per hour will give a P1t of about 0.65.
c) 7 % for equipment which is:
-
attended whilst in use (for example: hair dryers, vacuum cleaners, kitchen equipment such as
mixers, garden equipment such as lawn mowers, portable tools such as electric drills), or
-
-
switched on automatically, or is intended to be switched on manually, no more than twice per day,
and also has either a delayed restart (the delay being not less than a few tens of seconds) or manual
restart, after a power supply interruption. Pst and Plt requirements shall not be applied to voltage
changes caused by manual switching.
restart, after a power supply interruption. Pst and Plt requirements shall not be applied to voltage
changes caused by manual switching.
7.4 Test results
Mode
Table
Remarks
Result
TM1
006
230VAC 50Hz
Pass **
**)
There is no testing required if the device does not generate any significant voltage fluctuations or flicker.
(EN61000-3-3)
A short time measurement confirmed the assumption that this is the fact. The details in the test module
are representing the results of the short time measurement.
(EN61000-3-3)
A short time measurement confirmed the assumption that this is the fact. The details in the test module
are representing the results of the short time measurement.