JBL CS680 EMC - CB Certificate ▷ View online
page 5 of 34
Ref.No.:610604
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
7
HEATING UNDER NORMAL OPERATING CONDITIONS
(See appended table)
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
P
7.1.1
Temperature rise of accessible parts
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
P
7.1.4
Temperature rise of windings
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150 ºC
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150 ºC
N/A
8 CONSTRUCTIONAL
REQUIREMENTS
WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
Not used
P
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
P
8.5
Class
Ι equipment
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Capacitors bridging basic insulation complying with
14.2.1a
14.2.1a
N/A
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
Class
ΙΙ equipment and Class ΙΙ constructions
within Class
Ι equipment
N/A
page 6 of 34
Ref.No.:610604
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
8.6
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
Mains transformer
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
N/A
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
This clause is not considered
N/A
Reinforced or double insulation between circuits
operating at between 35 V and 71 V (peak) a.c. or
between 60 V and 120 V d.c. and hazardous live
parts at higher voltage
operating at between 35 V and 71 V (peak) a.c. or
between 60 V and 120 V d.c. and hazardous live
parts at higher voltage
N/A
Separation by Class
ΙΙ isolating transformer
N/A
Separation by Class
Ι transformer
N/A
Separation by earthed conductive part
N/A
8.8
Basic or supplementary insulation
≥ 0.4 mm (mm) : Prim. wires
P
Reinforced insulation
≥ 0.4 mm (mm) .................... : Transformer bobbins
P
Thin
sheet
insulation
N/A
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers
any two of which meet 10.3
any two of which meet 10.3
N/A
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N/A
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Applies to class I - appliances
N/A
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
N/A
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
Live wires are double
insulated.
insulated.
No sec. wires can come into
contact with live parts
contact with live parts
P
page 7 of 34
Ref.No.:610604
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
8.11
Detaching of wires
No undue reduction of creepage or clearance
distances if wires become detached
distances if wires become detached
No risk of any wire becoming
detached
detached
N/A
Vibration test carried out ........................................ : No, no need. See above
N/A
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
N/A
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
P
8.14
Adequate fastening of covers (pull test 50 N, for
10 s)
10 s)
P
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
P
8.16
Only special supply equipment can be used
N/A
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1.1
Touch current measured from terminal devices
using the network in Annex D ................................ :
using the network in Annex D ................................ :
U1 = 0.08Vp (253V)
U2 = 0.09Vp (253V)
P
Discharge not exceeding 45
μC
N/A
Energy of discharge not exceeding 350 mJ
N/A
Test with test finger and test probe
P
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
P
9.1.3
Ventilation holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
N/A
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe 16 of IEC 61032
pin (10 N); test probe 16 of IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1N); test probe D of IEC 61032
straight wire (1N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after 2 s :
withdrawal of the mains plug; voltage (V) after 2 s :
N/A
If C is not greater than 0.1
μF no test needed
P
page 8 of 34
Ref.No.:610604
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
9.1.7
Enclosure sufficiently resistant to external force
P
Test probe 11 of IEC 61032 for 10 s (50 N)
P
Test hook of fig. 4 for 10 s (20 N)
P
30 mm diameter test tool for 5 s (100 or 250 N) ... :
N/A
9.2
No hazard after removing a cover by hand
N/A
10
INSULATION REQUIREMENTS
(See appended table)
10.1
Insulation resistance (M
Ω) at least 2 MΩ min. after
surge test for basic and 4 M
Ω min. for reinforced
insulation
>100M
Ω
P
10.2
Humidity treatment 48 h or 120 h
Both 48 and 120 h ( see also
page 32 )
page 32 )
P
10.3
Insulation resistance and dielectric strength
P
11
FAULT CONDITIONS
(See
appended
table)
11.1
No shock hazard under fault conditions
P
11.2
Heating under fault condition
P
No hazard from softening solder
P
11.2.1
Measurement of temperature rises
P
11.2.2
Temperature rise of accessible parts
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of Table 2 by max. 100 K for
max. 5 min
exceeding the limits of Table 2 by max. 100 K for
max. 5 min
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of Table 2 by not
more than 100 K for an area not greater than
2 cm
to 20.1.3, exceeding the limits of Table 2 by not
more than 100 K for an area not greater than
2 cm
2
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm
to 20.1.3 up to 300 K for an area not greater than
2 cm
2
for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
At Uin=198V, voltage across
interruption <50Vp
At Uin=253V, no interruption,
mains fuse broke
interruption <50Vp
At Uin=253V, no interruption,
mains fuse broke
(see table 11)
P
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
P