JBL CS680 EMC - CB Certificate ▷ View online
page 25 of 34
Ref.No.:610604
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
6 D115
( - +)
sc 198 --
Mains
fuse
>2.6A
Mains fuse blew immediately.
No remarks.
7 D110
( - +)
sc 198 --
Mains
fuse
>2.6A
Mains fuse blew immediately.
No remarks.
8 C117 sc 198
--
--
-- P
mains
decreased to 8W.
No hazard.
page 26 of 34
Ref.No.:610604
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14
TABLE: list of critical components and materials
P
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
Mains
Transformer
Transformer
Transtec
TT0869803320
AC 230-240V
IEC 60065
—
Thermal link
Joint Force
M33
2A, 250V,
130
°C
IEC 60691
TÜV
Alt. Mains
Transformer
Transformer
Transtec
TT0869803320-E
AC 230-240V
IEC 60065
—
Alt. Thermal link
Joint Force
L33
2A, 250V,
130
°C
IEC 60691
TÜV
Mains Fuse
Walter
TSD
T1.25AL 250V
IEC 60127
Appliance inlet
Chily
3528
10A 250V
FV 0
IEC60320
IEC 61058-1
Mains switch
Rong Feng Ind.
Co., Ltd
RF-1003 10(4)
8/80A,
250V Class II
IEC60065:98
Annex G
NEMKO
Cordset (also for
Korea):
plug
Well Shin
WS-019
10-16A 250V
WS-002E
10A 250V
connector
cord
H05VV-F
2 x 0.75mm²
IEC 60799
Transformer
Bobbins
Bobbins
EI Dupont de
Nemours
Nylon 66
101,101F
94V-2 Complies
with
FH 3-40mm/min
IEC 60707:81
—
Sec. connector
P103
JWT
A3963Wv2-5P
Min. FV 1
IEC 60707
—
PCB Jian
He
(Cheng Ho)
Various
Min. FV 1
IEC 60707
—
X capacitor
across the
mains switch
across the
mains switch
Europtronic
(Taiwan) Ind.
Corp.
MPX 0.10µF,
275V
X2
IEC 60384-14
2:nd ed.
Plastic tub
(internal
enclosure)
(internal
enclosure)
Chi Mei
ABS Polylac
PA-765B
1.5mm/94V-2
smallest
thickness used:
2mm
Complies with
FH 3-40mm/min
IEC 60707:81
—
Shrink tubing,
covering mains
switch and inlet
covering mains
switch and inlet
Dongguan
Quantai
T-2 VW-1
Complies
with
FH 3-40mm/min
IEC 60707:81
—
page 27 of 34
Ref.No.:610604
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
GROUP DIFFERENCES (COMMON MODIFICATIONS) TO IEC 60065
CONTENTS
Add the following annexes:
Annex ZB (normative) Special national conditions
Annex ZC (informative) A-deviations
P
1.1.1
Replace the text of note 1 by:
NOTE 1 This standard can be used as a guide for
the testing of battery operated apparatus.
the testing of battery operated apparatus.
P
3.1 Delete
the
note.
Add the following indent:
-
Exposure to excessive sound pressures from
headphones or earphones
headphones or earphones
NOTE A new method is under consideration by
CENELEC/TC 206
CENELEC/TC 206
P
15.1.1
Delete notes 1 and 2.
Add to note 4:
Attention is drawn to the fact that a standard is
under preparation (presently prEN 50074) for
socket-outlets which allow connection of Class II
appliances only.
under preparation (presently prEN 50074) for
socket-outlets which allow connection of Class II
appliances only.
P
15.2
Delete note 2.
P
16.1
Delete note 1.
P
16.2 Delete
the
note.
P
20
Delete note 2.
P
Annex B
Delete note 2.
P
B.5.4.1e)
Delete notes 1 and 2.
P
B.8.1
Delete notes 1, 2 and 3.
P
B.8.2 Delete
the
note.
P
B.14.12
Delete notes 1 and 2.
P
Annex G
Delete the note.
P
page 28 of 34
Ref.No.:610604
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
Annex P
Bibliography
Add the following notes for the standards
indicated:
indicated:
IEC 60130
NOTE: IEC 60130-9:1989 +
A1: 1993 are harmonized as EN
60130-9
(not
modified).
IEC 60169
NOTE: Parts 23, 24 and25 are
harmonized as Ens (not modified)
IEC 60173
NOTE: Harmonized as HD 27
S1: 1983 (not modified).
IEC 60260
NOTE: Harmonized as HD 98
S1: 1977 (not modified).
IEC 60335-2-56 NOTE: Harmonized as EN 60335-
2-56:1997
2-56:1997
(not
modified).
IEC 61040
NOTE: Harmonized as EN
61040:1992
(not
modified).
IEC 60695
NOTE: Harmonized as EN 60695
series
(not
modified).
P
Click on the first or last page to see other CS680 service manuals if exist.