DOWNLOAD JBL CS680 Service Manual ↓ Size: 3.7 MB | Pages: 48 in PDF or view online for FREE

Model
CS680
Pages
48
Size
3.7 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
cs680.pdf
Date

JBL CS680 EMC - CB Certificate ▷ View online

 
 
page 21 of 34 
Ref.No.:610604  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by 
 
 
 
Position of the functional switch (W) ...................... : 0 W in 0FF-position 
 
Operating conditions 
243.8V, 1/8 of the max. non-clipping output power using the pink noise signal acc. to 4.1.6 .  
Input signal connected to ’Line in L/R’ (See instructions in OM. Excerpt on page 3) 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
                198 
0.38 
50 
19 
                243.8 
0.4 
60 
20 
 
Loudspeaker impedance (
Ω) ................................. : 4Ω 
 
 
Several loudspeaker systems 
 
 
Marking of loudspeaker terminals 
High Level  out/in 
 
monitored point: 
dT (K) 
Permitted dT (K) 
Iron core of mains transformer  
43 
— 
Supply cords (Not under mechanical stress) 
18 
60 (50) 
PCB (supporting heat sink)  
37 
— 
Inside plastic cover 
24 
— 
Heat sink, on rear panel 
30 
40 (30) 
Rear panel, near control 
30 
40 (30) 
Buttons (plastic) 
16 
50 (40) 
 
 
Winding temperature rise measurements 
 
 Ambient 
temperature t1 (ºC) .................................. : 21 
 
 
Ambient temperature t2 (
°C) .................................. : 22 
 
temperature rise dT of winding: 
R
1
 (
Ω) 
R
2
 (
Ω) 
dT (K) 
permitted 
dT (K) 
insulation 
class 
Transformer Primary winding 
9.031 
10.675 
46 
85(75) 
Transformer Secondary winding (Yellow) 
0.5599 
0.6528 
42 
85(75) 
Transformer Secondary winding (Red) 1.1043 
1.283 41 
85(75) E 
Note: Permitted dT in parenthesis are for tropical climate (Singapore) 
 
 
page 22 of 34 
Ref.No.:610604  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
Operating conditions 
253V (for UK) 1/8 of the max. non-clipping output power using the pink noise signal acc. to 4.1.6 .  
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
                253 
0.4 
60 
21 
monitored point: 
dT (K) 
Permitted dT (K) 
Supply cords (Not under mechanical stress) 
24*
)
 60 
Wiring insulation touching D115 
45*
)
 60 
Inside plastic cover 
26*
)
 — 
Heat sink Q117 
48*
)
 — 
Iron core of mains transformer  
44*
)
 — 
PCB supported by R121/R122 
44*
)
 85 
Heat sink, on rear panel 
31 
40 
Rear panel, near control 
31 
40 
Buttons (plastic) 
17 
50 
 
Winding temperature rise measurements 
 
 Ambient 
temperature t1 (ºC) .................................. : 21 
 
 
Ambient temperature t2 (
°C) .................................. : 22 
 
temperature rise dT of winding: 
R
1
 (
Ω) 
R
2
 (
Ω) 
dT (K) 
permitted 
dT (K) 
insulation 
class 
Transformer Primary winding 
9.202 
10.85 
45*
)
 85  E 
Transformer Secondary winding (Yellow) 
0.562 
0.650 
40*
)
 85  E 
Transformer Secondary winding (Red) 
1.104 
1.28 
41*
)
 85  E 
Note: 
*
values from tests on SUB100 Amplifier ref. No. 0141125 
 
 
 
page 23 of 34 
Ref.No.:610604  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
7.2 
TABLE: softening temperature of thermoplastics 
N/A 
temperature T of part 
T - normal  
conditions (ºC) 
T - fault  
conditions (ºC) 
T softening 
(ºC) 
 
 
 
 
 
 
10.3 
TABLE: insulation resistance measurements 
insulation resistance R between: 
R (M
Ω) 
required R (M
Ω) 
Between the poles of the circuit directly connected to the 
supply mains. 
>10 min.2 
Reinforced insulation. 
>10 
min.4 
 
 
10.3 
TABLE: electric strength measurements 
test voltage applied between: 
test voltage (V) 
Breakdown 
Between the poles of the circuit directly connected to the 
supply mains. 
2120V peak 
No 
Reinforced insulation. 
4240V peak 
No 
 
 
 
 
page 24 of 34 
Ref.No.:610604  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0.9 or 1.06 times rated voltage ........... : 220-230 
 
 
Ambient temperature (
°C) ...................................... : 22 
 
 
Winding temperature rise measurements 
 
 Ambient 
temperature t1 (ºC) .................................. : 22 
 
 Ambient 
temperature t2 (ºC) .................................. : 22 
 
No
Component 
No. 
Fault  Test voltage 
 (V) 
Test  
time 
Fuse No.
Fuse  
current 
(A) 
Result 
1a 
Max. non-
clipping 
output 
power  
(pink noise) 
— 243.8  4h Mains 
fuse 
0.6 
1b 
Max. non-
clipping 
output 
power  
(pink noise) 
— 253  4h 
Mains 
fuse 
0.6 
2 Q105  sc  198 
--  Mains 
fuse 
>2.6A 
Mains fuse blew immediately. 
No remarks. 
3 Q107  sc  198 
--  Mains 
fuse 
>2.6A 
Mains fuse blew immediately. 
No remarks. 
4 C133  sc  198 
--  Mains 
fuse 
>2.6A 
Mains fuse blew immediately. 
No remarks. 
5a C122  sc  253 
--  Mains 
fuse 
>2.6A 
Mains fuse blew immediately. 
No remarks. 
5b C122  sc  198 
--  Mains 
fuse 
≤2.3A 
Pin=450→260W, Iin=2.3→1.5A 
Printed conductors on the PCB 
were interrupted. When the 
conductors were bridged the 
thermal link in the transformer 
opened after 3.5 min. No remarks. 
Page of 48
Display