DOWNLOAD JBL CHARGE (serv.man4) Service Manual ↓ Size: 1018.46 KB | Pages: 76 in PDF or view online for FREE

Model
CHARGE (serv.man4)
Pages
76
Size
1018.46 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
charge-sm4.pdf
Date

JBL CHARGE (serv.man4) EMC - CB Certificate ▷ View online

Report No.:  EM201200703-6                Application No.:  ZJ00022653                        Page 57 of 76 
 
 
5.5.4 TEST RESULTS 
EUT 
Portable wireless speaker 
Mode Number 
JBL Charge 
Test date 
2012-11-15 
Voltage Supply 
AC 230V/50Hz 
Test Engineer 
Liang 
environment 
Tem:21℃ Hum:50 %100kPa 
Test mode: 
1. Test the EUT in BT (Adapter )、Audio in (Adapter ); 
2. Test the EUT in idle mode. 
 
Test Point 
Polarity 
Test Level 
(kV) 
Required Passing 
Performance 
Actual 
performance 
Result 
+/- 
Criterion B 
Criterion A* 
PASS 
+/- 
Criterion B 
Criterion A* 
PASS 
L–N 
+/- 
Criterion B 
Criterion A* 
PASS 
A*There was no change compared with the initial operation during the test. 
 
Report No.:  EM201200703-6                Application No.:  ZJ00022653                        Page 58 of 76 
 
 
5.6 SURGE IMMUNITY TEST 
5.6.1 TEST SPECIFICATION 
Basic Standard:  
EN 61000-4-5:2006 
Wave-Shape: 
CW 1.2µs/50µs 
Test Voltage: 
Line to line 0.5kV; line to PE 1kV 
Generator Source Impedance: 
Line to line 2ohm; line to PE 12ohm 
Polarity: 
Positive and Negative 
Phase Angle: 
0°, 90°, 180°, 270° 
Pulse Repetition Rate: 
60s 
Number of Tests: 
5 times 
5.6.2 TEST PROCEDURE  
a)  For EUT power supply: 
The surge is applied to the EUT power supply terminals via the capacitive coupling network. Decoupling 
networks are required in order to avoid possible adverse effects on equipment not under test that may be 
powered by the same lines, and to provide sufficient decoupling impedance to the surge wave. The power 
cord between the EUT and the coupling/decoupling networks was shorter than 2 meters in length. 
b)  For test applied to unshielded un-symmetrically operated interconnection lines of EUT: The surge was 
applied to the lines via the capacitive coupling. The coupling / decoupling networks didn’t influence the 
specified functional conditions of the EUT. The interconnection line between the EUT and the 
coupling/decoupling networks was shorter than 2 meters in length. 
c) For test applied to unshielded symmetrically operated interconnection / telecommunication lines of 
EUT:The surge was applied to the lines via gas arrestors coupling. Test levels below the ignition point of 
the coupling arrestor were not specified. The interconnection line between the EUT and the 
coupling/decoupling networks was shorter than 2 meters in length. 
5.6.3 TEST SETUP 
 
Report No.:  EM201200703-6                Application No.:  ZJ00022653                        Page 59 of 76 
 
 
5.6.4 TEST RESULTS 
EUT 
Portable wireless speaker 
Mode Number 
JBL Charge 
Test date 
2012-11-15 
Voltage Supply 
AC 230V/50Hz 
Test Engineer 
Liang 
environment 
Tem:21℃ Hum:50 %100kPa 
Test mode: 
1. Test the EUT in BT (Adapter )、Audio in (Adapter ); 
2. Test the EUT in idle mode. 
 
Test Point   Polarity
Test 
Level 
(kV) 
Phase
Performanc
Criterion 
Actual 
performanc
Result 
(P/F) 
L - N 
+/- 1 0°  B 
PASS 
+/- 1 90°  B 
PASS 
+/- 1 
180° B 
PASS 
+/- 1 
270° B 
PASS 
 
A*There was no change compared with the initial operation during the test. 
 
 
Report No.:  EM201200703-6                Application No.:  ZJ00022653                        Page 60 of 76 
 
 
5.7 INJECTED CURRENTS SUSCEPTIBILITY TEST 
5.7.1 TEST SPECIFICATION 
Basic Standard 
EN 61000-4-6:2009 
Frequency Range 
0.15 MHz-80 MHz 
Field Strength 
3 V 
Modulation 
1 kHz,80% AM 
Frequency Step 
1% 
Dwell time 
2s 
5.7.2 TEST PROCEDURE  
1)  Set up the EUT, CDN as shown on Section 5.7.3 
2)  Let the EUT work in test mode and measure it. 
3)   The EUT are placed on an insulating support 0.1m high above a ground reference plane. CDN 
(coupling and decoupling device) is placed on the ground plane about 0.3m from EUT. Cables 
between CDN and EUT are as short as possible, and their height above the ground reference 
plane shall be between 30 and 50 mm (where possible). 
4)  The disturbance signal described below is injected to EUT through CDN. 
5)  The EUT operates within its operational mode(s) under intended climatic conditions after 
power on. 
6)  The frequency range is swept from 150 kHz to 80MHz using 3V signal level, and with the 
disturbance signal 80% amplitude modulated with a 1 kHz sine wave. 
7) The rate of sweep shall not exceed 1.5*10-3decades/s. Where the frequency is swept 
incrementally, the step size shall not exceed 1% of the start and thereafter 1% of the preceding 
frequency value. 
8) Recording the EUT operating situation during compliance testing and decide the EUT 
immunity criterion. 
Page of 76
Display