DOWNLOAD JBL CHARGE (serv.man4) Service Manual ↓ Size: 1018.46 KB | Pages: 76 in PDF or view online for FREE

Model
CHARGE (serv.man4)
Pages
76
Size
1018.46 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
charge-sm4.pdf
Date

JBL CHARGE (serv.man4) EMC - CB Certificate ▷ View online

Report No.:  EM201200703-6                Application No.:  ZJ00022653                        Page 45 of 76 
 
 
Project No.: 
ZJ00022653 
Probe: 
Standard: 
(CE)EN55022 class B_QP 
Power Source: 
AC 230V/50Hz 
Test item: 
Conduction Test 
Date: 
2012-11-13 
Temp./Hum.(%RH): 22/46%RH 
Time: 
20:33:34 
EUT: 
Portable wireless speaker 
 
 
Model: 
JBL CHARGE 
Test Result: 
Pass 
Note:  
Audio inAdapter 
 
 
 
 
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBuV) 
Factor(dB) 
(dBuV) 
(dBuV) 
(dB) 
 
1 0.2818 29.70 10.50 40.20 
60.76 
-20.56 
QP 
2 0.2818 19.60 10.50 30.10 
50.76 
-20.66  AVG 
3 0.5780 33.00 10.50 43.50 
56.00 
-12.50 
QP 
4 0.5780 27.40 10.50 37.90 
46.00 -8.10  AVG 
5 0.7100 34.13 10.47 44.60 
56.00 
-11.40 
QP 
6 0.7100 31.33 10.47 41.80 
46.00 -4.20  AVG 
7 1.1500 33.15 10.55 43.70 
56.00 
-12.30 
QP 
8 1.1500 25.25 10.55 35.80 
46.00 
-10.20  AVG 
9 1.5740 31.52 10.58 42.10 
56.00 
-13.90 
QP 
10 1.5740 25.52 10.58 36.10 46.00 -9.90 
AVG 
11 3.5059 26.89 10.61 37.50 56.00 -18.50 
QP 
12 3.5059 19.89 10.61 30.50 46.00 -15.50  AVG 
 
Report No.:  EM201200703-6                Application No.:  ZJ00022653                        Page 46 of 76 
 
 
4.3 VOLTAGE FLUCTUATION AND FLICKS MEASUREMENT 
4.3.1 LIMITS 
Test standard: EN 61000-3-3:2008 
Test Item 
Limit 
Remark 
P
st
 1.0 
P
st 
means short-term flicker indicator. 
P
lt
 0.65 
P
lt
 means long-term flicker indicator. 
T
dt
 (ms) 
500 
T
dt 
means maximum time that dt exceeds 3 %. 
d
max
 (%) 
4% 
d
max
 means maximum relative voltage change. 
dc (%) 
3.3% 
dc means relative steady-state voltage change 
4.3.2 TEST PROCEDURES 
The EUT was placed on the top of a wooden table 0.8 meters above the ground and operated 
to produce the most unfavorable sequence of voltage changes under normal operating 
conditions. 
During the flick measurement, the measure time shall include that part of whole operation 
cycle in which the EUT produce the most unfavorable sequence of voltage changes. The 
observation period for short-term flicker indicator is 10 minutes and the observation period 
for long-term flicker indicator is 2 hours. 
4.3.3 TEST SETUP 
 
 
Harmonics & 
Flicker 
Analyzer 
Power Source 
 
EUT 
 
Support  
Power 
Cord
 
0.8
Report No.:  EM201200703-6                Application No.:  ZJ00022653                        Page 47 of 76 
 
4.3.4 TEST RESULTS 
 
Flicker Test Summary per EN/IEC61000-3-3  (Run time) 
 
EUT: Portable wireless speaker 
                               Tested by: chenjt 
       Test Margin: 100 
Test date: 2012-11-12            Start time: 14:18:01         End time: 14:28:22 
Test duration (min): 10 
                                           Data file name: F-000575.cts_data 
Comment: JBL Charge 
Customer: Customer 
 
Test Result: Pass 
Status: Test Completed 
 
 
Psti and limit line 
 
 
0.25
0.50
0.75
1.00
  
Pst
14:28:21
 
Plt and limit line  
0.00
0.25
0.50
  
Plt
14:28:21
 
Parameter values recorded during the test: 
Vrms at the end of test (Volt): 
229.96 
Highest dt (%): 
-0.32 
Test limit (%): 
3.30 
Pass 
Time(mS) > dt:   
0.0 
Test limit (mS):  500.0 
Pass 
Highest dc (%): 
0.00 
Test limit (%): 
3.30 
Pass 
Highest dmax (%): 
0.17 
Test limit (%): 
4.00 
Pass 
Highest Pst (10 min. period):         0.064 
  Test limit:                1.000 
Pass  
 
Highest Plt (2 hr. period):               0.028 
Test limit:                0.650 
Pass 
Report No.:  EM201200703-6                Application No.:  ZJ00022653                        Page 48 of 76 
 
5. IMMUNITY TEST 
5.1 GENERAL DESCRIPTION 
Product Standard 
ETSI EN 301 489-17 V2.2.1 (2012-09) & EN 301 489-1 V1.9.2(2011-09) 
Test set-up 
Test specification 
ETSI EN 301 489-17 
V2.1.1 (2009-05) & EN 
301 489-1 
V1.9.2(2011-09) 
 
EN 61000-4-2 
Electrostatic Discharge – ESD: 
8kV air discharge, 4kV Contact discharge 
Performance Criterion B 
EN 61000-4-3 
Radio-Frequency Electromagnetic Field Susceptibility 
Test – RS: 
80 ~1000 MHz, 1400~2700 MHz 3V/m, 80% 
AM(1kHz),  
Performance Criterion A 
EN 61000-4-4 
Electrical Fast Transient/Burst - EFT, 
AC power Port: 1kV,  
DC power Port: 0.5kV 
Signal and control line: 0.5kV, 
Performance Criterion B 
EN 61000-4-5 
Surge Immunity Test: 
1.2/50 us Open Circuit Voltage, 
8 /20 us Short Circuit Current, 
AC Power Port: line to earth: ±1kV, line to line: ±0.5kV
Performance Criterion B 
EN 61000-4-6 
Conducted Radio Frequency Disturbances Test –CS: 
0.15 ~ 80 MHz, 3Vrms, 80% AM, 1kHz, 
Performance Criterion A 
EN 61000-4-11 
Voltage dips: 
30 during 25 periods, 
Meets the requirements of  Performance Criterion C
Voltage interruption: 
100% during 0.5 cycles, 
100% during 1 cycles, 
Meets the requirements of Performance Criterion B 
100% during 250 cycles, 
Meets the requirements of Performance Criterion C 
 