DOWNLOAD JBL CHARGE (serv.man4) Service Manual ↓ Size: 1018.46 KB | Pages: 76 in PDF or view online for FREE

Model
CHARGE (serv.man4)
Pages
76
Size
1018.46 KB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
charge-sm4.pdf
Date

JBL CHARGE (serv.man4) EMC - CB Certificate ▷ View online

Report No.:  EM201200703-6                Application No.:  ZJ00022653                        Page 49 of 76 
 
5.2 GENERAL PERFORMANCE CRITERIA DESCRIPTION 
Criteria A 
The apparatus shall continue to operate as intended during the test. No 
degradation of performance or loss of function is allowed below a performance 
level (or permissible loss of performance) specified by the manufacturer, when 
the apparatus is used as intended. If the minimum performance level or the 
permissible performance loss is not specified by the manufacturer, then either of 
these may be derived from the product description and documentation, and from 
what the user may reasonably expect from the apparatus if used as intended. 
Criteria B 
The apparatus shall continue to operate as intended after the test. No degradation 
of performance or loss of function is allowed below a performance level (or 
permissible loss of performance) specified by the manufacturer, when the 
apparatus is used as intended. During the test, degradation of performance is 
allowed, however, no change of actual operating state or stored data is allowed. If 
the minimum performance level or the permissible performance loss is not 
specified by the manufacturer, then either of these may be derived from the 
product description and documentation, and from what the user may reasonably 
expect from the apparatus if used as intended. 
Criteria C 
 Temporary loss of function is allowed, provided the function is self- recoverable 
or can be restored by the operation of the controls, or by any operation specified in 
the instructions for use. Not all functions of the apparatus need to be tested. The 
selection, the specification of functions, and the permissible degradation is left to 
the responsibility of the manufacturer. 
 
Report No.:  EM201200703-6                Application No.:  ZJ00022653                        Page 50 of 76 
 
 
5.3 ELECTROSTATIC DISCHARGE (ESD) 
5.3.1 TEST SPECIFICATION 
Basic Standard 
EN 61000-4-2:2009 
Discharge Impedance 
330 ohm / 150 pF 
Discharge Voltage 
Air Discharge       : 8 kV; 
Contact Discharge: 4 kV  
Polarity 
Positive & Negative 
Number of Discharge 
Minimum 10 times at each test point 
Discharge Mode 
Single Discharge 
1 second minimum 
5.3.2 TEST PROCEDURE  
The basic test procedure was in accordance with EN 61000-4-2: 
a) The EUT was located 0.1 m minimum from all side of the HCP (dimensions 1.6m * 0.8m). 
b) The support units were located another table 30 cm away from the EUT, but direct support unit 
was/were located at same location as EUT on the HCP and keep at a distance of 10 cm with EUT. 
c) The time interval between two successive single discharges was at least 1 second. 
d) Contact discharges were applied to the non-insulating coating, with the pointed tip of the generator 
penetrating the coating and contacting the conducting substrate. 
e) Air discharges were applied with the round discharge tip of the discharge electrode approaching the 
EUT as fast as possible (without causing mechanical damage) to touch the EUT. After each 
discharge, the ESD generator was removed from the EUT and re-triggered for a new single 
discharge. The test was repeated until all discharges were complete. 
f) At least ten single discharges (in the most sensitive polarity) were applied at the front edge of each 
HCP opposite the center point of each unit of the EUT and 0.1 meters from the front of the EUT. 
The long axis of the discharge electrode was in the plane of the HCP and perpendicular to its front 
edge during the discharge. 
g) At least ten single discharges (in the most sensitive polarity) were applied to the center of one 
vertical edge of the Vertical Coupling Plane (VCP) in sufficiently different positions that the four 
faces of the EUT were completely illuminated. The VCP (dimensions 0.5m * 0.5m) was placed 
vertically to and 0.1 meters from the EUT. 
Report No.:  EM201200703-6                Application No.:  ZJ00022653                        Page 51 of 76 
 
5.3.3 TEST SETUP 
 
 
 
Report No.:  EM201200703-6                Application No.:  ZJ00022653                        Page 52 of 76 
 
 
5.3.4 TEST RESULTS 
EUT 
Portable wireless speaker 
Mode Number 
JBL Charge 
Test date 
2012-11-15 
Voltage Supply 
AC 230V/50Hz;DC 3.7V 
Test Engineer 
Liang 
environment 
Tem:25 Hum:50 %100kPa 
Test mode: 
1. Test the EUT in BT (Adapter ) 、Audio in (Adapter )、BT(Battery)、 
Audio in (Battery);  
2. Test the EUT in idle mode. 
 
Discharge point 
Discharge 
voltage 
C-Conduct 
A-Air 
Required 
Passing 
Performance
Actual 
performance
Result
Nonmetallic 
exposed surface & 
button 
±8  kV 
Criterion B 
Criterion A* 
PASS 
Vertical coupling 
plane 
±4  kV 
Criterion B 
Criterion A* 
PASS 
Horizontal coupling 
plane 
±4  kV 
Criterion B 
Criterion A* 
PASS 
A*There was no change compared with the initial operation during the test. 