Report No.:  EM201200703-6                Application No.:  ZJ00022653                        Page 53 of 76 
 
 
5.4 RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD (RS) 
5.4.1 TEST SPECIFICATION 
Basic Standard 
EN 61000-4-3: 2006+A1: 2008+A2: 2010 
Frequency Range 
80 MHz ~1000 MHz 
1.4 GHz ~2.7GHz 
Field Strength 
3 V/m 
Modulation 
1kHz Sine Wave, 80%, AM Modulation 
Frequency Step 
1 % of preceding frequency value 
Dwell Time 
2s 
Polarity of Antenna 
Horizontal and Vertical 
Test Distance 
3 m 
Antenna Height 
1.5m 
 
5.4.2 TEST PROCEDURE  
a) The testing was performed in a fully anechoic chamber. The transmit antenna was located at a 
distance of 3 meters from the EUT. 
b) The frequency range is swept from 80 MHz to 1000 MHz; 1.4 GHz ~2.7GHz ,with the signal 80% 
amplitude modulated with a 1 kHz sine-wave. The rate of sweep did not exceed 1.5 x 10 
-3 
decade/s, where the frequency range is swept incrementally; the step size was 1% of preceding 
frequency value. 
c) The dwell time at each frequency shall be not less than the time necessary for the EUT to be able to 
respond. 
e) The test was performed with the EUT exposed to both vertically and horizontally polarized fields 
on each of the four sides. 
Report No.:  EM201200703-6                Application No.:  ZJ00022653                        Page 54 of 76 
 
 
5.4.3 TEST SETUP 
 
 
 
 
 
 
 
 
 
 
 
                                 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Power 
Amp 
Signal 
Generato
r
EUT Monitoring by 
using a camera
 
0.8m
Control Room
9
×
6
×
EUT& 
Support 
Units 
PC Controller to 
control S.G. & PA as 
well as forward 
power
 
3 meter 
1.5m 
Report No.:  EM201200703-6                Application No.:  ZJ00022653                        Page 55 of 76 
 
 
5.4.4 TEST RESULTS 
EUT 
Portable wireless speaker 
Mode Number 
JBL Charge 
Test date 
2012-11-15 
Voltage Supply 
AC 230V/50Hz;DC 3.7V 
Test Engineer 
Liang 
environment 
Tem:23℃ Hum:48 %100kPa 
Test mode: 
1. Test the EUT in BT (Adapter ) 、Audio in (Adapter )、BT(Battery)、 
Audio in (Battery); 
2. Test the EUT in idle mode. 
 
Frequency  
(MHz) 
Polarity 
Azimuth 
Field 
Strength
(V/m)
Required 
Passing 
Performance 
Actual 
performance
Result
80 ~ 1000 
V&H 
Front 
Criterion A 
Criterion A* PASS
80 ~ 1000 
V&H 
Rear 
Criterion A 
Criterion A* PASS
80 ~ 1000 
V&H 
Right 
Criterion A 
Criterion A* PASS
80 ~ 1000 
V&H 
Left 
Criterion A 
Criterion A* PASS
1400 ~ 2700 
V&H 
Front 
Criterion A 
Criterion A* PASS
1400 ~ 2700 
V&H 
Rear 
Criterion A 
Criterion A* PASS
1400 ~ 2700 
V&H 
Right 
Criterion A 
Criterion A* PASS
1400 ~ 2700 
V&H 
Left 
Criterion A 
Criterion A* PASS
A*There was no change compared with the initial operation during the test. 
Report No.:  EM201200703-6                Application No.:  ZJ00022653                        Page 56 of 76 
 
 
5.5 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST 
5.5.1 TEST SPECIFICATION 
Basic Standard 
EN 61000-4-4: 2004+A1: 2010 
Test Voltage 
Electrical Fast Transient/Burst – EFT: 
AC Power Port: ±1kV,Signal port ±0.5kV 
Performance Criterion B 
Polarity 
Positive and Negative 
Impulse Frequency 
5 kHz 
Impulse Wave-shape 
5 ns/50ns for voltage  
Burst Duration 
15 ms 
Burst Period 
300 ms 
Test Duration 
2 minutes 
5.5.2 TEST PROCEDURE  
 
The EUT and its simulators shall be placed 0.1m high above the ground reference plane which is a min. 
1m×1m metallic sheet with 0.65mm minimum thickness. This reference ground plane shall project 
beyond the EUT by at least 0.1m on all sides and the minimum distance between EUT and all other 
conductive structure, except the ground plane beneath the EUT, shall be more than 0.5m. 
For input and AC power ports
The EUT is connected to the power mains by using a coupling device which couples the EFT 
interference signal to AC power lines. Both polarities of the test voltage should be applied during 
compliance test and the duration of the test can’t less than 1min. 
5.5.3 TEST SETUP 
 
 
 
 
 
10 cm isolation 
supporter 
AC
 input 
EFT 
Generator 
EUT 
AC
  
AC Line 
Ground Reference Plane 
0.5m
Page of 76