JBL AUTHENTICS L8 (serv.man3) EMC - CB Certificate ▷ View online

Report No.: EM201300471-4                        Application No.:
 
ZJ00032008                    Page 9 of 41 
4. EMISSION TEST  
4.1 CONDUCTED EMISSION MEASUREMENT 
4.1.1 LIMITS 
Frequency (MHz) 
Quasi-peakdBμV) 
AveragedBμV 
0.15 ~ 0.5 
66~56 56~46 
0.5 ~ 5 
56 46 
5 ~ 30 
60 50 
NOTE
(1) The lower limit shall apply at the transition frequencies. 
(2) The limit decreases in line with the logarithm of the frequency in the range of  0.15 ~0.5 MHz. 
4.1.2 TEST PROCEDURES 
Procedure of Preliminary Test 
For measurement of the disturbance voltage the equipment under test (EUT) is connected to 
the power supply mains and any other extended network via one or more artificial network(s). 
An EUT, whether intended to be grounded or not, and which is to be used on a table is 
configured as follows: 
–   Either the bottom or the rear of the EUT shall be at a controlled distance of 40 cm from a 
reference ground plane. This ground plane is normally the wall or floor of a shielded room. It 
may also be a grounded metal plane of at least 2 m by 2 m. This is physically accomplished as 
follows: 
1)  place the EUT on a table of non-conducting material which is at least 80 cm high. Place the 
EUT so that it is 40 cm from the wall of the shielded room, or 
2)  place the EUT on a table of non-conducting material which is 40 cm high so that the 
bottom of the EUT is 40 cm above the ground plane; 
–    All other conductive surfaces of the EUT shall be at least 80 cm from the reference ground 
plane; 
–    The ANs are placed on the floor that one side of the AN housings is 40 cm from the 
vertical reference ground plane and other metallic parts; 
–    Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded 
back and forth forming a bundle 30 cm to 40 cm long, hanging approximately in the middle 
between the ground plane and the table. 
–    I/O cables that are connected to a peripheral shall be bundled in the centre. The end of the 
cable may be terminated if required using correct terminating impedance. The total length 
shall not exceed 1 m. 
The test mode(s) described in Item 2.4 were scanned during the preliminary test. After the 
preliminary scan, we found the test mode described in Item 2.4 producing the highest 
emission level. The EUT configuration and cable configuration of the above highest emission 
levels were recorded for reference of the final test. 
Procedure of Final Test  
EUT and support equipment were set up on the test bench as per the configuration with 
highest emission level in the preliminary test. A scan was taken on both power lines, 
Report No.: EM201300471-4                        Application No.:
 
ZJ00032008                    Page 10 of 41 
recording at least the six highest emissions. Emission frequency and amplitude were recorded 
into a computer in which correction factors were used to calculate the emission level and 
compare reading to the applicable limit. The test data of the worst-case condition(s) was 
recorded. 
4.1.3 TEST SETUP 
 
 
Report No.: EM201300471-4                        Application No.:
 
ZJ00032008                    Page 11 of 41 
4.1.4 TEST RESULTS 
Project No.: 
ZJ00032008 
Probe: 
L1 
Standard: 
(CE)EN55022 class B_QP 
Power Source: 
AC 230V/50Hz 
Test item: 
Conduction Test 
Date: 
2013-8-12 
Temp./Hum.(%RH): 21/56%RH 
Time: 
14:43:06 
EUT: 
JBL AUTHENTICS L16 
 
 
Model: 
Mode 1: Audio in 
Test Result: 
Pass 
Note:  
 
 
 
 
  
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBuV) 
Factor(dB) 
(dBuV) 
(dBuV) 
(dB) 
 
1 0.3940 42.09 0.51 42.60 
57.98 
-15.38 
QP 
2 0.3940 40.39 0.51 40.90 
47.98 -7.08  AVG 
3 1.1820 29.69 0.51 30.20 
56.00 
-25.80 
QP 
4 1.1820 24.99 0.51 25.50 
46.00 
-20.50  AVG 
5 2.7620 34.10 0.70 34.80 
56.00 
-21.20 
QP 
6 2.7620 29.10 0.70 29.80 
46.00 
-16.20  AVG 
7 8.3940 46.97 0.73 47.70 
60.00 
-12.30 
QP 
8 8.3940 38.37 0.73 39.10 
50.00 
-10.90  AVG 
9 8.9340 45.61 0.79 46.40 
60.00 
-13.60 
QP 
10 8.9340 38.11  0.79  38.90 50.00 -11.10  AVG 
11 16.0660 34.09  0.81  34.90 60.00 -25.10 
QP 
12 16.0660 28.69  0.81  29.50 50.00 -20.50 
AVG 
 
Report No.: EM201300471-4                        Application No.:
 
ZJ00032008                    Page 12 of 41 
 
Project No.: 
ZJ00032008 
Probe: 
Standard: 
(CE)EN55022 class B_QP 
Power Source: 
AC 230V/50Hz 
Test item: 
Conduction Test 
Date: 
2013-8-12 
Temp./Hum.(%RH): 21/56%RH 
Time: 
14:47:57 
EUT: 
JBL AUTHENTICS L16 
 
 
Model: 
Mode 1: Audio in 
Test Result: 
Pass 
Note:  
 
 
 
  
  
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBuV) 
Factor(dB) 
(dBuV) 
(dBuV) 
(dB) 
 
1 0.3940 42.39 0.51 42.90 
57.98 
-15.08 
QP 
2 0.3940 40.89 0.51 41.40 
47.98 -6.58  AVG 
3 1.1820 29.79 0.51 30.30 
56.00 
-25.70 
QP 
4 1.1820 24.99 0.51 25.50 
46.00 
-20.50  AVG 
5 1.9700 33.01 0.59 33.60 
56.00 
-22.40 
QP 
6 1.9700 28.51 0.59 29.10 
46.00 
-16.90  AVG 
7 2.7620 34.90 0.70 35.60 
56.00 
-20.40 
QP 
8 2.7620 30.30 0.70 31.00 
46.00 
-15.00  AVG 
9 4.3379 38.29 0.71 39.00 
56.00 
-17.00 
QP 
10 4.3379 32.69  0.71  33.40 46.00 -12.60  AVG 
11 8.3779 47.17  0.73  47.90 60.00 -12.10 
QP 
12 8.3779 38.27  0.73  39.00 50.00 -11.00  AVG 
 