JBL AUTHENTICS L8 (serv.man3) EMC - CB Certificate ▷ View online

Report No.: EM201300471-4                        Application No.:
 
ZJ00032008                    Page 33 of 41 
5.6 IMMUNITY TO AMBIENT ELECTROMAGNETIC FIELDS (S3) 
5.6.1 TEST REQUIREMENT 
Test Requirement: 
EN 55020 
Test Method: 
EN 55020 
Criterion Required: 
Wanted Signal:  
60dBuV 1KHz FM with 40KHz deviation at 98MHz for FM mode.  
 
1KHz Test sine wave for AUX mode.   
Unwanted Signal:  
1KHz AM 80% AM at the frequency listed below. 
Unwanted signal and immunity limit for FM tuner mode. 
Unwanted signal and immunity limit for AUX mode. 
 
Report No.: EM201300471-4                        Application No.:
 
ZJ00032008                    Page 34 of 41 
 
5.6.2 TEST RESULTS 
Test:   Immunity Radiated Fields S3 <AMP0816> 
  
 Test Mode:       Amplifier -                       Monitor:        Speaker 
 Operating Mode:  AUX                               S/N:            77.1 dB 
 Frequency:       -                                 AF Level:       11.0 mW 
   
 Interf. Signal: Scan, 160813-00002-001, 8/16/2013, 4:35:27PM      K2 = 1.6 dB 
 
100/50
90/60
70/80
50/100
30/120
10/140
0/150
S/N [dB] // Level [dB
/m]
150k
20M
40M
60M
80M
100M
120M
150M
Frequency [Hz]
 
Report No.: EM201300471-4                        Application No.:
 
ZJ00032008                    Page 35 of 41 
APPENDIX A: PHOTOGRAPH OF THE TEST CONFIGURATION
 
CE 
 
 
Disturbance power 
 
 
Report No.: EM201300471-4                        Application No.:
 
ZJ00032008                    Page 36 of 41 
ESD 
 
 
EFT 
 
Page of 41