DOWNLOAD JBL AUTHENTICS L8 (serv.man3) Service Manual ↓ Size: 1.75 MB | Pages: 41 in PDF or view online for FREE

Model
AUTHENTICS L8 (serv.man3)
Pages
41
Size
1.75 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
authentics-l8-sm3.pdf
Date

JBL AUTHENTICS L8 (serv.man3) EMC - CB Certificate ▷ View online

Report No.: EM201300471-4                        Application No.:
 
ZJ00032008                    Page 25 of 41 
 
g) At least ten single discharges (in the most sensitive polarity) were applied to the center of one 
vertical edge of the Vertical Coupling Plane (VCP) in sufficiently different positions that the four 
faces of the EUT were completely illuminated. The VCP (dimensions 0.5m * 0.5m) was placed 
vertically to and 0.1 meters from the EUT. 
5.3.3 TEST SETUP 
 
 
 
Report No.: EM201300471-4                        Application No.:
 
ZJ00032008                    Page 26 of 41 
 
5.3.4 TEST RESULTS 
EUT 
Active speaker system with wireless streaming 
Mode Number 
JBL AUTHENTICS L16 
Test date 
2013-08-20 
Voltage Supply 
AC 230V/50Hz 
Test Engineer 
Brain 
environment 
Tem:21 Hum:54 %100kPa 
Test mode: 
1. Test the EUT in mode 1:
AUDIOIN 
 
2. Test the EUT in mode 2:
WIFI 
 
3. Test the EUT in mode 3:
BT 
4. Test the EUT in mode 4:
Optical 
5. Test the EUT in mode 5:
Standby
 
 
Discharge point 
Discharge 
voltage 
C-Conduct 
A-Air 
Required 
Passing 
Performance
Actual 
performance
Result
Nonmetallic 
surface 
±8  kV 
Criterion B 
Criterion A* 
PASS
Gap 
±8  kV 
Criterion B 
Criterion A* 
PASS
Buttons 
±8  kV 
Criterion B 
Criterion A* 
PASS
Indicator lights 
±8  kV 
Criterion B 
Criterion A* 
PASS
Metal mesh cover 
±4  kV 
Criterion B 
Criterion A* 
PASS
Vertical coupling 
plane 
±4  kV 
Criterion B 
Criterion A* 
PASS
Horizontal coupling 
plane 
±4  kV 
Criterion B 
Criterion A* 
PASS
A*EUT is working on intended use operation, no abnormal phenomenon was observed. 
B*EUT is working and it has some noise and the volume is descended. It can recover after test. 
Report No.: EM201300471-4                        Application No.:
 
ZJ00032008                    Page 27 of 41 
 
5.4 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST 
5.4.1 TEST SPECIFICATION 
Basic Standard 
EN 61000-4-4: 2012 
Test Voltage 
Electrical Fast Transient/Burst – EFT: 
AC Power Port: ±1kV,Signal port ±0.5kV 
Performance Criterion B 
Polarity 
Positive and Negative 
Impulse Frequency 
5 kHz 
Impulse Wave-shape 
5 ns/50ns for voltage  
Burst Duration 
15 ms 
Burst Period 
300 ms 
Test Duration 
2 minutes 
5.4.2 TEST PROCEDURE  
 
The EUT and its simulators shall be placed 0.1m high above the ground reference plane which is a min. 
1m×1m metallic sheet with 0.65mm minimum thickness. This reference ground plane shall project 
beyond the EUT by at least 0.1m on all sides and the minimum distance between EUT and all other 
conductive structure, except the ground plane beneath the EUT, shall be more than 0.5m. 
For input and AC power ports
The EUT is connected to the power mains by using a coupling device which couples the EFT 
interference signal to AC power lines. Both polarities of the test voltage should be applied during 
compliance test and the duration of the test can’t less than 1min. 
5.4.3 TEST SETUP 
 
 
 
 
 
10 cm 
isolation 
supporter
AC
 input 
EFT 
Generator 
EUT 
AC
  
AC Line 
Ground Reference Plane 
0.5m
Report No.: EM201300471-4                        Application No.:
 
ZJ00032008                    Page 28 of 41 
 
5.4.4 TEST RESULTS 
EUT 
Active speaker system with wireless streaming 
Mode Number 
JBL AUTHENTICS L16 
Test date 
2013-08-20 
Voltage Supply 
AC 230V/50Hz 
Test Engineer 
Brian 
environment 
Tem:21℃ Hum:54 %100kPa 
Test mode: 
1. Test the EUT in mode 1:
AUDIOIN 
 
2. Test the EUT in mode 2:
WIFI 
 
3. Test the EUT in mode 3:
BT 
4. Test the EUT in mode 4:
Optical 
5. Test the EUT in mode 5:
Standby
 
 
Test Point 
Polarity 
Test Level 
(kV) 
Required Passing 
Performance 
Actual 
performance 
Result 
L–N 
+/- 
Criterion B 
Criterion A* 
PASS 
A*EUT is working on intended use operation, no abnormal phenomenon was observed. 
Page of 41
Display