JBL AUTHENTICS L8 (serv.man3) EMC - CB Certificate ▷ View online
Report No.: EM201300471-4 Application No.:
ZJ00032008 Page 25 of 41
g) At least ten single discharges (in the most sensitive polarity) were applied to the center of one
vertical edge of the Vertical Coupling Plane (VCP) in sufficiently different positions that the four
faces of the EUT were completely illuminated. The VCP (dimensions 0.5m * 0.5m) was placed
vertically to and 0.1 meters from the EUT.
5.3.3 TEST SETUP
Report No.: EM201300471-4 Application No.:
ZJ00032008 Page 26 of 41
5.3.4 TEST RESULTS
EUT
Active speaker system with wireless streaming
Mode Number
JBL AUTHENTICS L16
Test date
2013-08-20
Voltage Supply
AC 230V/50Hz
Test Engineer
Brain
environment
Tem:21 Hum:54 %100kPa
Test mode:
1. Test the EUT in mode 1:
AUDIOIN
2. Test the EUT in mode 2:
WIFI
3. Test the EUT in mode 3:
BT
4. Test the EUT in mode 4:
Optical
5. Test the EUT in mode 5:
Standby
Discharge point
Discharge
voltage
C-Conduct
A-Air
Required
Passing
Performance
Actual
performance
Result
Nonmetallic
surface
±8 kV
A
Criterion B
Criterion A*
PASS
Gap
±8 kV
A
Criterion B
Criterion A*
PASS
Buttons
±8 kV
A
Criterion B
Criterion A*
PASS
Indicator lights
±8 kV
A
Criterion B
Criterion A*
PASS
Metal mesh cover
±4 kV
C
Criterion B
Criterion A*
PASS
Vertical coupling
plane
±4 kV
C
Criterion B
Criterion A*
PASS
Horizontal coupling
plane
±4 kV
C
Criterion B
Criterion A*
PASS
A*: EUT is working on intended use operation, no abnormal phenomenon was observed.
B*: EUT is working and it has some noise and the volume is descended. It can recover after test.
B*: EUT is working and it has some noise and the volume is descended. It can recover after test.
Report No.: EM201300471-4 Application No.:
ZJ00032008 Page 27 of 41
5.4 ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
5.4.1 TEST SPECIFICATION
Basic Standard
EN 61000-4-4: 2012
Test Voltage
Electrical Fast Transient/Burst – EFT:
AC Power Port: ±1kV,Signal port ±0.5kV
Performance Criterion B
AC Power Port: ±1kV,Signal port ±0.5kV
Performance Criterion B
Polarity
Positive and Negative
Impulse Frequency
5 kHz
Impulse Wave-shape
5 ns/50ns for voltage
Burst Duration
15 ms
Burst Period
300 ms
Test Duration
2 minutes
5.4.2 TEST PROCEDURE
The EUT and its simulators shall be placed 0.1m high above the ground reference plane which is a min.
1m×1m metallic sheet with 0.65mm minimum thickness. This reference ground plane shall project
beyond the EUT by at least 0.1m on all sides and the minimum distance between EUT and all other
conductive structure, except the ground plane beneath the EUT, shall be more than 0.5m.
For input and AC power ports:
The EUT is connected to the power mains by using a coupling device which couples the EFT
interference signal to AC power lines. Both polarities of the test voltage should be applied during
compliance test and the duration of the test can’t less than 1min.
5.4.3 TEST SETUP
10 cm
isolation
supporter
isolation
supporter
AC
input
EFT
Generator
EUT
AC
AC Line
Ground Reference Plane
0.5m
Report No.: EM201300471-4 Application No.:
ZJ00032008 Page 28 of 41
5.4.4 TEST RESULTS
EUT
Active speaker system with wireless streaming
Mode Number
JBL AUTHENTICS L16
Test date
2013-08-20
Voltage Supply
AC 230V/50Hz
Test Engineer
Brian
environment
Tem:21℃ Hum:54 %100kPa
Test mode:
1. Test the EUT in mode 1:
AUDIOIN
2. Test the EUT in mode 2:
WIFI
3. Test the EUT in mode 3:
BT
4. Test the EUT in mode 4:
Optical
5. Test the EUT in mode 5:
Standby
Test Point
Polarity
Test Level
(kV)
Required Passing
Performance
Actual
performance
Result
L–N
+/-
1
Criterion B
Criterion A*
PASS
A*: EUT is working on intended use operation, no abnormal phenomenon was observed.