JBL AUTHENTICS L8 (serv.man3) EMC - CB Certificate ▷ View online

Report No.: EM201300471-4                        Application No.:
 
ZJ00032008                    Page 17 of 41 
 
Project No.: 
ZJ00032008 
Probe: 
L1 
Standard: 
(CE)EN55022 class B_QP 
Power Source: 
AC 230V/50Hz 
Test item: 
Conduction Test 
Date: 
2013-8-12 
Temp./Hum.(%RH): 21/56%RH 
Time: 
15:28:45 
EUT: 
JBL AUTHENTICS L16 
 
 
Model: 
Mode 4: Optical 
Test Result: 
Pass 
Note:  
 
 
 
  
  
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBuV) 
Factor(dB) 
(dBuV) 
(dBuV) 
(dB) 
 
1 0.3940 43.19 0.51 43.70 
57.98 
-14.28 
QP 
2 0.3940 41.79 0.51 42.30 
47.98 -5.68  AVG 
3 4.3380 38.19 0.71 38.90 
56.00 
-17.10 
QP 
4 4.3380 33.19 0.71 33.90 
46.00 
-12.10  AVG 
5 5.9140 40.26 0.74 41.00 
60.00 
-19.00 
QP 
6 5.9140 34.96 0.74 35.70 
50.00 
-14.30  AVG 
7 7.3540 41.54 0.86 42.40 
60.00 
-17.60 
QP 
8 7.3540 31.84 0.86 32.70 
50.00 
-17.30  AVG 
9 8.8060 45.72 0.78 46.50 
60.00 
-13.50 
QP 
10 8.8060 37.72  0.78  38.50 50.00 -11.50  AVG 
11 9.7540 45.44  0.76  46.20 60.00 -13.80 
QP 
12 9.7540 39.04  0.76  39.80 50.00 -10.20  AVG 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Report No.: EM201300471-4                        Application No.:
 
ZJ00032008                    Page 18 of 41 
 
Project No.: 
ZJ00032008 
Probe: 
Standard: 
(CE)EN55022 class B_QP 
Power Source: 
AC 230V/50Hz 
Test item: 
Conduction Test 
Date: 
2013-8-12 
Temp./Hum.(%RH): 21/56%RH 
Time: 
15:24:15 
EUT: 
JBL AUTHENTICS L16 
 
 
Model: 
Mode 4: Optical 
Test Result: 
Pass 
Note:  
 
 
 
  
  
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBuV) 
Factor(dB) 
(dBuV) 
(dBuV) 
(dB) 
 
1 0.3940 43.29 0.51 43.80 
57.98 
-14.18 
QP 
2 0.3940 42.19 0.51 42.70 
47.98 -5.28  AVG 
3 2.7620 35.10 0.70 35.80 
56.00 
-20.20 
QP 
4 2.7620 31.20 0.70 31.90 
46.00 
-14.10  AVG 
5 4.3340 37.39 0.71 38.10 
56.00 
-17.90 
QP 
6 4.3340 31.59 0.71 32.30 
46.00 
-13.70  AVG 
7 8.8060 45.42 0.78 46.20 
60.00 
-13.80 
QP 
8 8.8060 37.62 0.78 38.40 
50.00 
-11.60  AVG 
9 9.3380 45.52 0.78 46.30 
60.00 
-13.70 
QP 
10 9.3380 38.02  0.78  38.80 50.00 -11.20  AVG 
11 9.8540 45.44  0.76  46.20 60.00 -13.80 
QP 
12 9.8540 39.54  0.76  40.30 50.00 -9.70 
AVG 
Report No.: EM201300471-4                        Application No.:
 
ZJ00032008                    Page 19 of 41 
 
4.2 DISTURBANCE POWER MEASUREMENT 
4.2.1 LIMITS 
FREQUENCY (MHz) 
dBpW
Quasi-peak(dBpW) 
Average(dBpW) 
30 ~ 300 
45 to 55  (a) 
35 to 45  (a) 
Note:  (a) Increasing linearly with the frequency. 
4.2.2 TEST PROCEDURES 
The appliance to be tested is placed on a non-metallic table at least 0,4 m from other metallic 
objects and the lead to be measured on is stretched in a straight line for a distance sufficient to 
accommodate the absorbing clamp, and to permit the necessary measuring adjustment of 
position for tuning. The clamp is placed around the lead so as to measure a quantity 
proportional to the disturbance power on the lead. 
The absorbing clamp is positioned for maximum indication at each test frequency: the clamp 
shall be moved along the lead until the maximum value is found between a position adjacent 
to the appliance and a distance of about a half-wavelength from it. 
The straight portion of the lead to be measured on should therefore be about 6 m long, this 
being equal to λ max/2 + 0,6 m in order to allow at any time the positioning of the absorbing 
clamp and a possible second clamp for additional isolation. Pre-testing is carried out in all 
operating modes to find the worst mode for the every test terminal. 
4.2.3 TEST SETUP 
 
 
Report No.: EM201300471-4                        Application No.:
 
ZJ00032008                    Page 20 of 41 
4.2.4 TEST RESULTS 
Project No.: 
ZJ00032008 
 
 
Standard: DP 
EN55013 
QP Power 
Source: 
 
Test item: 
Power Clamp Test 
Date: 
2013-8-15 
Temp./Hum.(%RH): 21/56%RH 
Time: 
13:30:21 
EUT: 
JBL AUTHENTICS L16 
 
 
Model: 
Mode 1: Audio in 
Test Result: 
Pass 
Note:  
Audio in    Audio in line to EUT 
 
 
  
  
No. 
Frequency 
Reading 
Correct 
Result 
Limit 
Margin 
Remark 
 
(MHz) 
(dBpW) 
Factor(dB) 
(dBpW) 
(dBpW) 
(dB) 
 
1 30.0000 8.76  19.04 27.80 45.00 -17.20 
QP 
2 30.0000 -0.54  19.04 18.50 35.00 -16.50  AVG 
3 33.2800 10.07 17.63 27.70 45.12 -17.42 
QP 
4 33.2800 3.47  17.63 21.10 35.12 -14.02  AVG 
5 36.8400 6.49  16.61 23.10 45.25 -22.15 
QP 
6 36.8400 2.49  16.61 19.10 35.25 -16.15  AVG 
7 61.4400 11.13 14.97 26.10 46.16 -20.06 
QP 
8 61.4400 9.73  14.97 24.70 36.16 -11.46  AVG 
9 147.4400 11.37  17.13  28.50 49.35 -20.85 
QP 
10 147.4400 9.97  17.13  27.10  39.35 -12.25 
AVG 
11 215.0400 13.75  17.45  31.20  51.85 -20.65 
QP 
12 215.0400 12.55  17.45  30.00  41.85 -11.85 
AVG 
 