Report No.: EM201300471-4 Application No.:
ZJ00032008 Page 17 of 41
Project No.:
ZJ00032008
Probe:
L1
Standard:
(CE)EN55022 class B_QP
Power Source:
AC 230V/50Hz
Test item:
Conduction Test
Date:
2013-8-12
Temp./Hum.(%RH): 21/56%RH
Time:
15:28:45
EUT:
JBL AUTHENTICS L16
Model:
Mode 4: Optical
Test Result:
Pass
Note:
No.
Frequency
Reading
Correct
Result
Limit
Margin
Remark
(MHz)
(dBuV)
Factor(dB)
(dBuV)
(dBuV)
(dB)
1 0.3940 43.19 0.51 43.70
57.98
-14.28
QP
2 0.3940 41.79 0.51 42.30
47.98 -5.68 AVG
3 4.3380 38.19 0.71 38.90
56.00
-17.10
QP
4 4.3380 33.19 0.71 33.90
46.00
-12.10 AVG
5 5.9140 40.26 0.74 41.00
60.00
-19.00
QP
6 5.9140 34.96 0.74 35.70
50.00
-14.30 AVG
7 7.3540 41.54 0.86 42.40
60.00
-17.60
QP
8 7.3540 31.84 0.86 32.70
50.00
-17.30 AVG
9 8.8060 45.72 0.78 46.50
60.00
-13.50
QP
10 8.8060 37.72 0.78 38.50 50.00 -11.50 AVG
11 9.7540 45.44 0.76 46.20 60.00 -13.80
11 9.7540 45.44 0.76 46.20 60.00 -13.80
QP
12 9.7540 39.04 0.76 39.80 50.00 -10.20 AVG
Report No.: EM201300471-4 Application No.:
ZJ00032008 Page 18 of 41
Project No.:
ZJ00032008
Probe:
N
Standard:
(CE)EN55022 class B_QP
Power Source:
AC 230V/50Hz
Test item:
Conduction Test
Date:
2013-8-12
Temp./Hum.(%RH): 21/56%RH
Time:
15:24:15
EUT:
JBL AUTHENTICS L16
Model:
Mode 4: Optical
Test Result:
Pass
Note:
No.
Frequency
Reading
Correct
Result
Limit
Margin
Remark
(MHz)
(dBuV)
Factor(dB)
(dBuV)
(dBuV)
(dB)
1 0.3940 43.29 0.51 43.80
57.98
-14.18
QP
2 0.3940 42.19 0.51 42.70
47.98 -5.28 AVG
3 2.7620 35.10 0.70 35.80
56.00
-20.20
QP
4 2.7620 31.20 0.70 31.90
46.00
-14.10 AVG
5 4.3340 37.39 0.71 38.10
56.00
-17.90
QP
6 4.3340 31.59 0.71 32.30
46.00
-13.70 AVG
7 8.8060 45.42 0.78 46.20
60.00
-13.80
QP
8 8.8060 37.62 0.78 38.40
50.00
-11.60 AVG
9 9.3380 45.52 0.78 46.30
60.00
-13.70
QP
10 9.3380 38.02 0.78 38.80 50.00 -11.20 AVG
11 9.8540 45.44 0.76 46.20 60.00 -13.80
11 9.8540 45.44 0.76 46.20 60.00 -13.80
QP
12 9.8540 39.54 0.76 40.30 50.00 -9.70
AVG
Report No.: EM201300471-4 Application No.:
ZJ00032008 Page 19 of 41
4.2 DISTURBANCE POWER MEASUREMENT
4.2.1 LIMITS
FREQUENCY (MHz)
dBpW
Quasi-peak(dBpW)
Average(dBpW)
30 ~ 300
45 to 55 (a)
35 to 45 (a)
Note: (a) Increasing linearly with the frequency.
4.2.2 TEST PROCEDURES
The appliance to be tested is placed on a non-metallic table at least 0,4 m from other metallic
objects and the lead to be measured on is stretched in a straight line for a distance sufficient to
accommodate the absorbing clamp, and to permit the necessary measuring adjustment of
position for tuning. The clamp is placed around the lead so as to measure a quantity
proportional to the disturbance power on the lead.
The absorbing clamp is positioned for maximum indication at each test frequency: the clamp
shall be moved along the lead until the maximum value is found between a position adjacent
to the appliance and a distance of about a half-wavelength from it.
The straight portion of the lead to be measured on should therefore be about 6 m long, this
being equal to λ max/2 + 0,6 m in order to allow at any time the positioning of the absorbing
clamp and a possible second clamp for additional isolation. Pre-testing is carried out in all
operating modes to find the worst mode for the every test terminal.
4.2.3 TEST SETUP
Report No.: EM201300471-4 Application No.:
ZJ00032008 Page 20 of 41
4.2.4 TEST RESULTS
Project No.:
ZJ00032008
Standard: DP
EN55013
QP Power
Source:
Test item:
Power Clamp Test
Date:
2013-8-15
Temp./Hum.(%RH): 21/56%RH
Time:
13:30:21
EUT:
JBL AUTHENTICS L16
Model:
Mode 1: Audio in
Test Result:
Pass
Note:
Audio in Audio in line to EUT
No.
Frequency
Reading
Correct
Result
Limit
Margin
Remark
(MHz)
(dBpW)
Factor(dB)
(dBpW)
(dBpW)
(dB)
1 30.0000 8.76 19.04 27.80 45.00 -17.20
QP
2 30.0000 -0.54 19.04 18.50 35.00 -16.50 AVG
3 33.2800 10.07 17.63 27.70 45.12 -17.42
3 33.2800 10.07 17.63 27.70 45.12 -17.42
QP
4 33.2800 3.47 17.63 21.10 35.12 -14.02 AVG
5 36.8400 6.49 16.61 23.10 45.25 -22.15
5 36.8400 6.49 16.61 23.10 45.25 -22.15
QP
6 36.8400 2.49 16.61 19.10 35.25 -16.15 AVG
7 61.4400 11.13 14.97 26.10 46.16 -20.06
7 61.4400 11.13 14.97 26.10 46.16 -20.06
QP
8 61.4400 9.73 14.97 24.70 36.16 -11.46 AVG
9 147.4400 11.37 17.13 28.50 49.35 -20.85
9 147.4400 11.37 17.13 28.50 49.35 -20.85
QP
10 147.4400 9.97 17.13 27.10 39.35 -12.25
AVG
11 215.0400 13.75 17.45 31.20 51.85 -20.65
QP
12 215.0400 12.55 17.45 30.00 41.85 -11.85
AVG