Report Reference No.: 079-206896-000 
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Test Report IEC 60065E Rev. 00 / 2004-09 
 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 
 
Test hook of fig. 4 for 10 s (20 N) 
 
 
30 mm diameter test tool for 5 s (100 or 250 N) .... : Applied 100 N  
9.2 
No hazard after removing a cover by hand 
No removing covers by hand 
10 INSULATION 
REQUIREMENTS 
          
 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation ................................................................. :
> 4 MΩ P 
10.2 
Humidity treatment 48 h or 120 h ........................... : 120 h 
10.3 
Insulation resistance and dielectric strength 
(see appended table) 
11 FAULT 
CONDITIONS 
⎯ 
11.1 
No shock hazard under fault condition 
 
11.2 
Heating under fault condition 
 
 
No hazard from softening solder 
 
11.2.1 
Measurement of temperature rises 
(see appended table) 
11.2.2 
Temperature rise of accessible parts 
(see appended table) 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
(see appended table) 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
 N 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not 
more than 100 K for an area not greater than 2 cm²
 N 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min 
 N 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
 N 
 
Class I protective earthing maintained 
 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
 N 
11.2.5 
Temperature rise of windings 
(see appended table) 
11.2.6 
Temperature rise of parts not subject to the limits 
of 11.2.1 to 11.2.5 
(see appended table) 
12 MECHANICAL 
STRENGTH 
⎯ 
12.1.1 
Bump test where mass >7 kg 
 
12.1.2 
Vibration test 
No damage & connection 
loosening 
12.1.3 
Impact hammer test 
 
Page 9 of 22  
Report Reference No.: 079-206896-000 
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Test Report IEC 60065E Rev. 00 / 2004-09 
 
Steel ball test 
 
12.1.4 
Drop test for portable apparatus where mass < 7 
kg 
 N 
12.1.5 
Thermoplastic enclosures strain relief test 
 
12.2 
Fixing of knobs, push buttons, keys and levers 
 
12.3 
Remote controls with hazardous live parts 
 
12.4 
Drawers (pull test 50 N, 10 s) 
No drawers 
12.5 
Antenna coaxial sockets providing isolation 
 
12.6 
Telescoping or rod antennas construction 
 
12.6.1 
Telescoping or rod antennas securement 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
⎯ 
13.1 
Clearances in accordance with 13.3 
(see appended table) 
 
Creepage distances in accordance with 13.4 
(see appended table) 
13.2 
Determination of operating voltage 
(see appended table) 
13.3 Clearances 
 
⎯ 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9 
(see appended table) 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
(see appended table) 
13.4 Creepage 
distances 
 
 
Creepage distances greater than table 11 minima 
(see appended table) 
13.5 Printed 
boards 
 
⎯ 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 N 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only) 
 N 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
 N 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 N 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12 
 N 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
 N 
14 COMPONENTS 
⎯ 
14.1 Resistors 
Page 10 of 22  
Report Reference No.: 079-206896-000 
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Test Report IEC 60065E Rev. 00 / 2004-09 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
No such resistors 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N 
 
b) Resistors separately approved ........................... : No 
14.2 
Capacitors and RC units 
 
 
Capacitors separately approved 
Yes 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition  ... : Not used Y-capacitors 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition ... : C900 
(see appended table 14) 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 ...................... :
No N 
14.2.5 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better ....................................................................... :
 N 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better  ........................................ :
 N 
 
Shielded by a barrier to V-0 or metal ...................... : Metal chassis 
14.3 
Inductors and windings 
 
⎯ 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 N 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type ............................... :
Manufacturer’s Identification:  
SET 
Type: CLT5M026YE/ 
 KLT5M026YE 
 
Transformers and inductors separately approved  . : No. Tested in apparatus 
14.3.2 General 
Isolation 
transformer 
14.3.3 Constructional 
requirements 
 
⎯ 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
Complied with the 
requirements of clause 13 
14.3.3.2 
Transformers meet the constructional 
requirements 
Complied P 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Reinforced insulation  
 
Coil formers and partition walls > 0,4 mm 
 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
No such transformer used 
Windings of class II 
construction 
Page 11 of 22  
Report Reference No.: 079-206896-000 
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Test Report IEC 60065E Rev. 00 / 2004-09 
14.3.4.3 
Separating transformers with at least basic 
insulation 
Windings of class II 
construction 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
Double or reinforced insulation 
between hazardous live 
windings and accessible 
conductive parts 
 
Coil formers and partition walls > 0,4 mm 
 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
 N 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N 
14.4 
High voltage components 
 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
No high voltage components 
used 
 
Component meets category V-1 of IEC 60707 
 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 N 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 N 
14.5 Protective 
devices 
 
⎯ 
 
Protective devices used within their ratings 
Fuses (F901) in appliance and 
thermal links in T901 and 
T902 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
 P 
14.5.1.1 
a) Thermal cut-outs separately approved 
 
 
b) Thermal cut-outs tested as part of the 
submission 
 N 
14.5.1.2 
a) Thermal links separately approved 
Provided in main transformer 
and standby transformer. No 
thermal link 
 
b) Thermal links tested as part of the submission 
 
14.5.1.3 
Thermal devices re-settable by soldering 
No such thermal devices 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
(see appended table14) 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ... : F901, T1AL, 250 V 
14.5.2.3 
Not possible to connect fuses in parallel ................ : No fuse holder so designed 
that fuse-links can be 
connected in parallel 
Page of 40