Page 8 of 22
Report Reference No.: 079-206896-000
Clause
Requirement – Test
Result - Remark
Verdict
Test Report IEC 60065E Rev. 00 / 2004-09
Test probe 11 of IEC 61032 for 10 s (50 N)
P
Test hook of fig. 4 for 10 s (20 N)
P
30 mm diameter test tool for 5 s (100 or 250 N) .... : Applied 100 N
P
9.2
No hazard after removing a cover by hand
No removing covers by hand
N
10 INSULATION
REQUIREMENTS
⎯
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
> 4 MΩ P
10.2
Humidity treatment 48 h or 120 h ........................... : 120 h
P
10.3
Insulation resistance and dielectric strength
(see appended table)
P
11 FAULT
CONDITIONS
⎯
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
P
No hazard from softening solder
P
11.2.1
Measurement of temperature rises
(see appended table)
P
11.2.2
Temperature rise of accessible parts
(see appended table)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(see appended table)
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
N
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N
Class I protective earthing maintained
N
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
N
11.2.5
Temperature rise of windings
(see appended table)
P
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
of 11.2.1 to 11.2.5
(see appended table)
P
12 MECHANICAL
STRENGTH
⎯
12.1.1
Bump test where mass >7 kg
P
12.1.2
Vibration test
No damage & connection
loosening
loosening
P
12.1.3
Impact hammer test
P
Page 9 of 22
Report Reference No.: 079-206896-000
Clause
Requirement – Test
Result - Remark
Verdict
Test Report IEC 60065E Rev. 00 / 2004-09
Steel ball test
P
12.1.4
Drop test for portable apparatus where mass < 7
kg
kg
N
12.1.5
Thermoplastic enclosures strain relief test
P
12.2
Fixing of knobs, push buttons, keys and levers
P
12.3
Remote controls with hazardous live parts
N
12.4
Drawers (pull test 50 N, 10 s)
No drawers
N
12.5
Antenna coaxial sockets providing isolation
N
12.6
Telescoping or rod antennas construction
N
12.6.1
Telescoping or rod antennas securement
N
13
CLEARANCE AND CREEPAGE DISTANCES
⎯
13.1
Clearances in accordance with 13.3
(see appended table)
P
Creepage distances in accordance with 13.4
(see appended table)
P
13.2
Determination of operating voltage
(see appended table)
P
13.3 Clearances
⎯
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
(see appended table)
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
(see appended table)
P
13.4 Creepage
distances
P
Creepage distances greater than table 11 minima
(see appended table)
P
13.5 Printed
boards
⎯
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
N
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N
14 COMPONENTS
⎯
14.1 Resistors
N
Page 10 of 22
Report Reference No.: 079-206896-000
Clause
Requirement – Test
Result - Remark
Verdict
Test Report IEC 60065E Rev. 00 / 2004-09
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such resistors
N
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N
b) Resistors separately approved ........................... : No
N
14.2
Capacitors and RC units
P
Capacitors separately approved
Yes
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition ... : Not used Y-capacitors
N
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition ... : C900
(see appended table 14)
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ...................... :
connected to the mains: tests for X2 ...................... :
No N
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
N
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
N
Shielded by a barrier to V-0 or metal ...................... : Metal chassis
P
14.3
Inductors and windings
⎯
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N
14.3.1
Transformers and inductors marked with
manufacturer's name and type ............................... :
manufacturer's name and type ............................... :
Manufacturer’s Identification:
SET
Type: CLT5M026YE/
KLT5M026YE
P
Transformers and inductors separately approved . : No. Tested in apparatus
N
14.3.2 General
Isolation
transformer
P
14.3.3 Constructional
requirements
⎯
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
Complied with the
requirements of clause 13
requirements of clause 13
P
14.3.3.2
Transformers meet the constructional
requirements
requirements
Complied P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Reinforced insulation
P
Coil formers and partition walls > 0,4 mm
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
No such transformer used
Windings of class II
construction
Windings of class II
construction
N
Page 11 of 22
Report Reference No.: 079-206896-000
Clause
Requirement – Test
Result - Remark
Verdict
Test Report IEC 60065E Rev. 00 / 2004-09
14.3.4.3
Separating transformers with at least basic
insulation
insulation
Windings of class II
construction
construction
N
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Double or reinforced insulation
between hazardous live
windings and accessible
conductive parts
between hazardous live
windings and accessible
conductive parts
P
Coil formers and partition walls > 0,4 mm
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N
14.4
High voltage components
N
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
No high voltage components
used
used
N
Component meets category V-1 of IEC 60707
N
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N
14.5 Protective
devices
⎯
Protective devices used within their ratings
Fuses (F901) in appliance and
thermal links in T901 and
T902
thermal links in T901 and
T902
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
P
14.5.1.1
a) Thermal cut-outs separately approved
N
b) Thermal cut-outs tested as part of the
submission
submission
N
14.5.1.2
a) Thermal links separately approved
Provided in main transformer
and standby transformer. No
thermal link
and standby transformer. No
thermal link
P
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices re-settable by soldering
No such thermal devices
N
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
(see appended table14)
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : F901, T1AL, 250 V
P
14.5.2.3
Not possible to connect fuses in parallel ................ : No fuse holder so designed
that fuse-links can be
connected in parallel
connected in parallel
N