Page 11 of 22
Report Reference No.: 079-206896-000
Clause
Requirement – Test
Result - Remark
Verdict
Test Report IEC 60065E Rev. 00 / 2004-09
14.3.4.3
Separating transformers with at least basic
insulation
insulation
Windings of class II
construction
construction
N
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
Double or reinforced insulation
between hazardous live
windings and accessible
conductive parts
between hazardous live
windings and accessible
conductive parts
P
Coil formers and partition walls > 0,4 mm
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N
14.4
High voltage components
N
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
No high voltage components
used
used
N
Component meets category V-1 of IEC 60707
N
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N
14.5 Protective
devices
⎯
Protective devices used within their ratings
Fuses (F901) in appliance and
thermal links in T901 and
T902
thermal links in T901 and
T902
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
P
14.5.1.1
a) Thermal cut-outs separately approved
N
b) Thermal cut-outs tested as part of the
submission
submission
N
14.5.1.2
a) Thermal links separately approved
Provided in main transformer
and standby transformer. No
thermal link
and standby transformer. No
thermal link
P
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices re-settable by soldering
No such thermal devices
N
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
(see appended table14)
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : F901, T1AL, 250 V
P
14.5.2.3
Not possible to connect fuses in parallel ................ : No fuse holder so designed
that fuse-links can be
connected in parallel
connected in parallel
N
Page 12 of 22
Report Reference No.: 079-206896-000
Clause
Requirement – Test
Result - Remark
Verdict
Test Report IEC 60065E Rev. 00 / 2004-09
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......... :
replacing fuse-links without the use of a tool ......... :
No replacement of fuse
possible by hand
possible by hand
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
N
PTC-S devices (15 W) category V-1 or better
N
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
and their position is correctly marked
N
14.6 Switches
⎯
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
V-0 compliance with annex G, G.1.1
P
14.6.1 b)
Tested in the apparatus:
N
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3,
14.6.4 and V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.3,
14.6.4 and V-0 in annex G, G.1.1
N
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1
N
Switch controlling < 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.4 and
V-0 in annex G, G.1.1
N
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
N
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
N
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
N
Socket outlet current marking correct
N
14.7
Safety interlocks
No safety interlocks
N
Safety interlocks to 2.8 of IEC 60950
N
14.8
Voltage setting devices
No voltage setting devices
N
Voltage setting device not likely to be changed
accidentally
accidentally
N
14.9 Motors
No
motors
N
14.9.1
Endurance test on motors
N
Page 13 of 22
Report Reference No.: 079-206896-000
Clause
Requirement – Test
Result - Remark
Verdict
Test Report IEC 60065E Rev. 00 / 2004-09
Motor start test
N
Dielectric strength test
N
14.9.2
Not adversely affected by oil or grease etc.
N
14.9.3
Protection against moving parts
N
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
motors and series motors meet clause. B.8, B.9
and B.10 of IEC 60950, Annex B
N
14.10
Batteries
No batteries inside
N
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
N
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N
14.10.3
Recharging currents and times within
manufacturers limits
manufacturers limits
N
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N
14.10.4
Battery mould stress relief
N
14.10.5
Battery drop test
N
14.11 Optocouplers
⎯
Optocouplers comply with Cl. 8
N
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
alternatively 13.6 (jointed insulation)
N
14.12
Surge suppression varistors
⎯
Comply with IEC 61051-2
N
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
parts except for earthed parts of permanently
connected apparatus
N
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
N
15 TERMINALS
⎯
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
(see appended table)
P
15.1.2
Connectors for antenna, earth, audio, video or data:
⎯
No risk of insertion in mains socket-outlets
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
No such risk of insertion
P
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-
outlets
not compatible with household mains socket-
outlets
Not compatible with household
mains socket-outlets
mains socket-outlets
P
15.2
Provision for protective earthing
⎯
Page 14 of 22
Report Reference No.: 079-206896-000
Clause
Requirement – Test
Result - Remark
Verdict
Test Report IEC 60065E Rev. 00 / 2004-09
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
Class II apparatus
N
Class I supply equipment with non-hazardous live
output voltage: output circuit not connected to earth
output voltage: output circuit not connected to earth
N
Protective earth conductors correctly coloured
N
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
N
Protective earth terminal resistant to corrosion
N
Earth resistance test: < 0,1
Ω at 25 A ................... : N
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
permanent connection to the mains supply
N
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
N
15.3.2
Reliable connection of non-detachable cords:
P
Not soldered to conductors of a printed circuit
board
board
P
Adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
P
Wire secured by additional means to the conductor
P
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
N
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
prior to soldering or held in place by additional
means
N
Clamping of conductor and insulation if not
soldered or held by screws
soldered or held by screws
P
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current
of the equipment
sectional area of conductors, for the rated current
of the equipment
P
15.3.6
Terminals to 15.3.3 have sizes required by table 16
N
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
P
Terminals designed to avoid conductor slipping out
when tightened or loosened
when tightened or loosened
P
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
when the clamping is tightened or loosened and
stress on internal wiring is avoided
P
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
No contact pressure
P
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
P