Page 3 of 22
Report Reference No.: 079-206896-000
Test Report IEC 60065E Rev. 00 / 2004-09
Copy of marking plate
:
Page 4 of 22
Report Reference No.: 079-206896-000
Clause
Requirement – Test
Result - Remark
Verdict
Test Report IEC 60065E Rev. 00 / 2004-09
3 GENERAL
REQUIREMENTS
⎯
Safety class of the apparatus ................................. : Class II apparatus
P
4
GENERAL CONDITIONS OF TESTS
⎯
4.1.4
Ventilation instructions require the use of the test
box
box
No. Ventilation requirement is
stated in use’s manual
stated in use’s manual
N
5 MARKING
⎯
Comprehensible and easily discernible
On the rear
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water and
petroleum spirit
petroleum spirit
P
5.1 Identification,
maker, model ................................... : See page 3
P
Class II symbol if applicable
Symbol
IEC 60417-5172
indicated
P
Rated supply voltage and symbol .......................... : 230 V
P
Frequency if safety dependant
50 Hz
P
Rated current or power consumption ..................... : 12 W
P
5.2 Earth
terminal
Class II apparatus
N
Hazardous live terminals
No hazardous live terminals
N
Supply output terminals (other than mains)
No output terminal
N
5.3
Use of triangle with exclamation mark
In circuit diagram
P
5.4
Instructions for use
In English
P
5.4.1
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled with
liquid, etc.
or splashing. Warning concerning objects filled with
liquid, etc.
The warning instruction for
water is indicated on User’s
manual
water is indicated on User’s
manual
P
Hazardous live terminals, instructions for wiring
No hazardous live terminals
N
Instructions for replacing lithium battery
No lithium batteries
N
Instructions for modem if fitted
No modems
N
Class I earth connection warning
Class II apparatus
N
Instructions for multimedia system connection
No connectors for multimedia
system
system
N
Special stability warning for fixed installation
No fixed installation
N
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
Mains plug
P
Instructions for permanently connected equipment
No permanently connected
equipment
equipment
N
6 HAZARDOUS
RADIATION
⎯
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation
N
Page 5 of 22
Report Reference No.: 079-206896-000
Clause
Requirement – Test
Result - Remark
Verdict
Test Report IEC 60065E Rev. 00 / 2004-09
6.1
EN 60065
European Council Directive 96/29/Euratom of 13
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
May 1996 10cm from outer surface of apparatus
<1µSv/h (0,1mR/h)
N
6.2
Laser radiation, emission limits to IEC 60825-1 .... : No laser
N
Emission limits under fault conditions .................... :
N
7
HEATING UNDER NORMAL OPERATING CONDITIONS
⎯
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
(see appended table)
P
7.1.1
Temperature rise of accessible parts
(see appended table)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table)
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
N
7.1.4
Temperature rise of windings
(see appended table)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
N
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
⎯
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
Considered P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Tools are required
P
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic material
P
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
No cover removed by hand
N
8.5
Class I equipment
N
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N
Resistors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N
8.6
Class II equipment and Class II constructions
within Class I equipment
within Class I equipment
N
Reinforced or double insulation between hazardous
live parts and accessible parts
live parts and accessible parts
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
Transformer, T901
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N
Page 6 of 22
Report Reference No.: 079-206896-000
Clause
Requirement – Test
Result - Remark
Verdict
Test Report IEC 60065E Rev. 00 / 2004-09
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
N
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
N
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N
8.7
Basic insulation between parts at 35 V to 71 V
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
(peak) a.c. or 60 V to 120 V d.c. and accessible
parts
No such voltage
N
Reinforced or double insulation between circuits
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
operating at voltages between 35 V and 71 V
(peak) a.c. or between 60 V and 120 V d.c. and
hazardous live parts at higher voltage
No such voltage
N
Separation by Class II isolating transformer
T901 P
Separation by Class I transformer
N
Separation by earthed conductive part
N
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N
Reinforced insulation > 0,4 mm (mm) .................... : Transformer bobbin:
0,86 mm
P
Thin sheet insulation
Insulation tape in T901
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
N
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Double insulated
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
P
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
P
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Primary wires in external cords
connected with multi-contact-
housing
connected with multi-contact-
housing
P
Vibration test carried out ......................................... : See clause 12.1.2
P
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
No mains socket-outlets
N