Harman Kardon TU 970II (serv.man2) EMC - CB Certificate ▷ View online

Page 19 of 22  
Report Reference No.: 079-206896-000 
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Test Report IEC 60065E Rev. 00 / 2004-09 
 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by(W)  
3,8 W 
— 
 
Position of the functional switch .............................. : 
On front 
— 
 
-  Continuous operation. 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
Operation mode 
207 V / 50 Hz 
0,06 
10,0 
— 
230 V / 50 Hz 
0,06 
11,4 
— 
253 V / 50 Hz 
0,07 
13,0 
— 
Stand-by mode 
207 V / 50 Hz 
0,02 
2,5 
— 
230 V / 50 Hz 
0,03 
3,0 
— 
253 V / 50 Hz 
0,05 
3,8 
— 
 
      
Loudspeaker impedance (Ω) .................................. : 
 
— 
      
Several loudspeaker systems 
 
 
      
Marking of loudspeaker terminals 
 
 
Monitored point: 
Measured dT(K) 
207 V/50 Hz 
Measured dT(K) 
253 V/50 Hz 
Limit dT (K) 
Main transformer (T901) core 
19,9 
25,2 
75 
Primary connector (CN91) 
10,8 
12,5 
Secondary wire (BN92) 
14,0 
16,7 
50 
PCB near T901 
13,9 
16,9 
85 
PCB near D901 
39,0 
43,7 
85 
PCB near IC92 
25,3 
38,2 
85 
Bushing body 
6,4 
6,6 
45 
Standby switch knob 
4,4 
4,8 
40 
Top enclosure above T901 
5,1 
5,6 
30 
ANTENNA DAB 
8,7 
8,4 
20 
Room ambient 
23,8 °C 25,4 
°
 
      
Winding temperature rise measurements 
      
Ambient temperature t1 (
o
C)  .................................. :      25,5 
— 
      
Ambient temperature t2 (
o
C)  .................................. :      1) 23,8 / 2) 25,4 
— 
 
 
 
Page 20 of 22  
Report Reference No.: 079-206896-000 
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Test Report IEC 60065E Rev. 00 / 2004-09 
 
Temperature rise dT of winding: 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Limit dT (K)  Insulation 
class 
1) T901 (207 V, 50 Hz) 
107,74 
116,12 
18,5 
75 
2) T901 (253 V, 50 Hz) 
107,74 
119,30 
26,1 
75 
 
10.3 
TABLE: insulation resistance measurements 
 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Between mains poles (primary fuse disconnected) 
> 100 
Between parts separated by basic or supplementary insulation 
Between parts separated by double or reinforced insulation 
> 100 
 
10.3 
TABLE: electric strength measurements 
 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Mains poles (primary fuse disconnected) 
2120 Vpeak 
No 
Between parts separated by basic or supplementary insulation 
Between parts separated by double or reinforced insulation 
4240 Vpeak 
No 
 
11.2 
TABLE: summary of fault condition tests 
      
Voltage (V) 0,9 or 1,1 times rated voltage .............. : 253 V 
— 
      
Ambient temperature (
o
C)  ...................................... : 24,4 °C–26,7 °C 
— 
 
No.  Component 
No. 
Fault 
Test  
voltage 
(V) 
Test 
Time 
Fuse 
No. 
Short 
current 
(A) 
Result 
D906 
S/C 
253 
199 min
F901 
0,04 
D907 damaged. 
After 150 min immediately unit shutdown. 
No hazard. 
2 D903 S/C 
253 30 
min
F901 
Transformer Pri. Winding heated up to 
106,3 K and thermal fuse opened. 
No hazard. 
3 D908 S/C 
253 
140 min
F901 
0,10 
Temperature stabilized at T901 winding: 
99,3 K, PCB (T901): 50,5 K, 
Ambient: 24,4 °C. No hazard. 
4 D909 S/C 
253 18 
min
F901 
Transformer Pri. Winding heated up to 
110,4 K and thermal fuse opened. 
No hazard. 
5 D912 S/C 
253 14 
min
F901 
Transformer Pri. Winding heated up to 
106,1 K and thermal fuse opened. 
No hazard. 
6 D904 S/C 
253 23 
min
F901 
Transformer Pri. Winding heated up to 
109,9 K and thermal fuse opened. 
No hazard. 
 
Page 21 of 22  
Report Reference No.: 079-206896-000 
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Test Report IEC 60065E Rev. 00 / 2004-09 
 
7 C930 S/C 
253 27 
min
F901 
Transformer Pri. Winding heated up to 
124,5 K and thermal fuse opened. 
No hazard. 
8 C912 S/C 
253 33 
min
F901 
Transformer Pri. Winding heated up to 
107,5 K and thermal fuse opened. 
No hazard. 
S/C: Short circuit 
 
13 
CLEARANCES AND CREEPAGE DISTANCES 
Working Voltage 
(V) 
Clearance 13.3 
(mm) 
Creepage distance
13.4  (mm) 
Type of 
insulation 
Position/ 
Location 
Position/ 
Location 
Up 
Urms 
Required
Measured
Required 
Measured
Comm
-ent 
B Live 
 
(pri.) 
Neutral 
(pri.) 
336 230 2,0 4,0 2,5 4,0 
3
B Load 
side 
of F901 
Input side 
of F901 
336 230 2,0 4,5 2,5 4,5 
4
)
 
R Live 
(pri.) 
Sec. 
GND 
336 236 4,0 7,5 5,0 7,5 
2
R pri. 
winding 
(of T901) 
sec. 
winding 
(of T901) 
360 246 4,0 5,9 5,0 5,9 
1
Comments 
1
)
 The clearances and creepage distances are measured on transformer. 
 
2
)
 The voltages listed are the shortest on PCB. 
The clearances and creepage distances are measured on PCB 
 
3
)
 The clearances and creepage distances are measured before fuse. 
 
4
)
 The clearances and creepage distances are measured between fuse leads on PCB. 
 
14 
TABLE: list of critical components and materials 
 
Component 
Manufacturer / 
trademark 
Type/model 
Value / rating 
Standard 
Approval / 
Reference 
Kenic Electric 
Mfg. 
KE-21 
250 V, 2,5 A 
EN 50075 
FIMKO 
Mains plug 
(for Europe)
 
Kenic Electric 
Mfg. 
KE-32 
250 V, 2,5 A 
EN 50075 
FIMKO 
Kenic Electric 
Mfg. 
H05VVH2-F 
2 x 0,75 mm
2
 EN 
50075 
IEC 60227 
FIMKO 
Flexible cable 
(for Europe)
 
Kenic Electric 
Mfg. Co., Ltd. 
H03VVH2-F 
2 x 0,75 mm
2
 VDE 
0281-5  VDE 
Kenic Electric 
Mfg. 
KE-108 
250 V, 13 A 
SS 145 
BS1363 
BSI, PSB 
Mains plug 
(for UK / 
SINGAPORE)
 
Luen Tai 
Electrical 
9518 
250 V, 13 A 
BS 1363 
BSI 
Page 22 of 22  
Report Reference No.: 079-206896-000 
 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Test Report IEC 60065E Rev. 00 / 2004-09 
 
Kenic Electric 
Mfg. 
H05VVH2-F 
2 x 0,75 mm
2
 EN 
50075 
IEC 60227 
FIMKO, SEV 
Flexible cable 
(for UK / 
SINGAPORE)
 
 
Kenic Electric 
Mfg. Co., Ltd. 
H03VVH2-F 
2 x 0,75 mm
2
 VDE 
0281-5, 
BS6500, 
IEC 60227 
VDE, BSI, PSB, 
SEV 
Orisel Co., Ltd. 
50T 
T1AL, 250 V 
EN 60127-2 
VDE, S 
Fuse (F901) 
Suzhou Littelfuse 
OVS Ltd. 
218.xxx T1AL, 250 V 
EN 60127-1, 
EN 60127-2 
VDE 
Okaya Electric 
RE 
275 V, 0,1uF,  
X2 
EN 132400 
FIMKO 
Carli Electronics  MPX 
275 V, 0,1uF,  
X2 
EN 132400 
IEC 60384-14 2
nd
  
VDE, FI 
X-Capacitor 
(C900) 
Yuchang 
Electronics 
WBU 1942 
275 V, 0,1uF,  
X2 
EN 132400 
IEC 60384-14 2
nd
  
VDE, FI 
Phone-Poulenc A205F 
V-2 
Sam Jin Corp. 
DACH-1 
Nylon 66 (V-2) 
Bushing 
Rhodia 
Engineering 
Plastics 
A 205F 
V-2 
UL94 
 
UL 
Main transformer 
(T901) 
 
Seoul 
Electronics  
& Telecom 
KLT5M026YE/ 
CLT5M026YE 
 
230 V, 50 Hz 
 
 
EN 60065 
 
 
Tested in 
appliance 
 
Thermal link in 
transformer 
Anzen Dengu 
K4F 
250 V, 1 A, 
127 °C 
EN 60691 
VDE 
Sam Yang Co. 
2550GN30 
EI Dupot 
FR530 
Transformer 
bobbin 
WIN Tech 
CN9030 
V-0 UL94 UL 
Connector 
(CN91) 
Yeonho 
YW-396, YH-396 250 V, 3 A 
VDE 0627 
VDE 0470 
TUV 
Top Faith P C B 
Co., Ltd. 
TF-03, TF-05 
V-0, 130 °C 
PCB 
Various 
Various 
V-0, Min. 130 °C
UL94 
 
 
 
UL 
1
) an asterisk indicates a mark which assures the agreed level of surveillance 
 
Page of 40
Display