Harman Kardon TU 970II (serv.man2) EMC - CB Certificate ▷ View online
Page 2 of 22
Report Reference No.: 079-206896-000
Test Report IEC 60065E Rev. 00 / 2004-09
Test item
Description ......................................... :
FM/AM/DAB Tuner
Trademark.......................................... :
Model and/or type reference.............. : TU970II
Manufacturer/Factory............................: 1. Manufacturer: Same as client. (44210)
2. Factory:
1) Same as client. (44210)
2) DongGuan LiaoBu Anam Electronics Co., Ltd. (44372)
Xin Cheng Management Area, LiaoBu Town, DongGuan City,
523426, GuangDong Province, People’s Republic of China.
1) Same as client. (44210)
2) DongGuan LiaoBu Anam Electronics Co., Ltd. (44372)
Xin Cheng Management Area, LiaoBu Town, DongGuan City,
523426, GuangDong Province, People’s Republic of China.
Rating(s)............................................. : 230 V , 50 Hz, 12 W, Class II
Test case verdicts
Test case does not apply to the test object .................. : N(.A.)
Test item does meet the requirement........................... : P(ass)
Test item does not meet the requirement .................... : F(ail)
Testing
Date of receipt of test item ........................................... :
Date(s) of performance of test……………………….…:
2006-05-23
2006-05-30 ~ 2006-06-23
Attachments:
1. National differences...............................................: 10 pages
2. Circuit diagram.......................................................: 1 page
3. Photograps ............................................................: 5 pages
General remarks
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by a NCB, in accordance with IECEE 02.
This report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item(s) tested.
"(see appended table)" refers to a table appended to the report.
“(see remark #)” refers to a remark appended to the report.
“(see Annex #) refers to an annex appended to the report.
Throughout this report a comma (point) is used as the decimal separator.
Summary of Testing and Conclusions
- Weight of appliance: 3,2 kg
-
Product dimensions: Overall size 440 mm(W) by 300 mm(D) by 64 mm(H).
-
The sample(s) tested complies with the requirements of IEC 60065:2001.
Page 3 of 22
Report Reference No.: 079-206896-000
Test Report IEC 60065E Rev. 00 / 2004-09
Copy of marking plate
:
Page 4 of 22
Report Reference No.: 079-206896-000
Clause
Requirement – Test
Result - Remark
Verdict
Test Report IEC 60065E Rev. 00 / 2004-09
3 GENERAL
REQUIREMENTS
⎯
Safety class of the apparatus ................................. : Class II apparatus
P
4
GENERAL CONDITIONS OF TESTS
⎯
4.1.4
Ventilation instructions require the use of the test
box
box
No. Ventilation requirement is
stated in use’s manual
stated in use’s manual
N
5 MARKING
⎯
Comprehensible and easily discernible
On the rear
P
Permanent durability against water and petroleum
spirit
spirit
Tested with water and
petroleum spirit
petroleum spirit
P
5.1 Identification,
maker, model ................................... : See page 3
P
Class II symbol if applicable
Symbol
IEC 60417-5172
indicated
P
Rated supply voltage and symbol .......................... : 230 V
P
Frequency if safety dependant
50 Hz
P
Rated current or power consumption ..................... : 12 W
P
5.2 Earth
terminal
Class II apparatus
N
Hazardous live terminals
No hazardous live terminals
N
Supply output terminals (other than mains)
No output terminal
N
5.3
Use of triangle with exclamation mark
In circuit diagram
P
5.4
Instructions for use
In English
P
5.4.1
Mains powered equipment not exposed to dripping
or splashing. Warning concerning objects filled with
liquid, etc.
or splashing. Warning concerning objects filled with
liquid, etc.
The warning instruction for
water is indicated on User’s
manual
water is indicated on User’s
manual
P
Hazardous live terminals, instructions for wiring
No hazardous live terminals
N
Instructions for replacing lithium battery
No lithium batteries
N
Instructions for modem if fitted
No modems
N
Class I earth connection warning
Class II apparatus
N
Instructions for multimedia system connection
No connectors for multimedia
system
system
N
Special stability warning for fixed installation
No fixed installation
N
5.4.2
Disconnect device: plug/coupler or all-pole mains
switch location, accessibility and markings
switch location, accessibility and markings
Mains plug
P
Instructions for permanently connected equipment
No permanently connected
equipment
equipment
N
6 HAZARDOUS
RADIATION
⎯
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No ionizing radiation
N