Ref.No.: 313603 
IEC 60065 
Cl. 
Requirement - Test 
Result - Remark 
Verdict 
 
16.3b 
(16.4b) 
 
Delete “Subclause 3.1 of IEC Publication 
60227-2: Part 2: Test Methods“ and insert 
“Subclause 9.1 of SS 236“: 
9.1 Flexing test (except for tinsel cords, 
twisted twin and single core cords). The test 
shall be carried out  by means of the 
apparatus shown in Figure 5. This apparatus 
has a carrier C supporting two pulleys A and 
B arranged so that the cord is horizontal 
between the pulleys. The carrier moves 
backward and forward over a distance of 1 m 
at an approximately constant speed of 0.33 
m/s.                                                 
A sample of flexible cord about 5 m long shall 
be stretched over the pulleys as shown in the 
figure, each end being loaded with a weight. 
The weight and the diameter of the pulleys A 
and B shall be given in Table 1. 
Screene cords in accordance with Table 7 shall 
be tested before application of the screen and 
outer sheath.                                                      
The pulleys shall have a semi-circular shaped 
groove for circular cords and a flat groove for 
parallel twin cords. The restraining clamps D shall 
be fixed so that the pull is always applied by the 
weight from which the carrier is moving away. 
The carrier shall make 30 000 backward and 
forward movements (60 000 single strokes). Each 
conductor of the sample shall be loaded with the 
current specified in Table 2.                                
For twin cords and for light PVC-sheated 3-core 
cords, the voltage between the conductors shall 
be approximately 230 V a.c. For all other cords 
having three or more cores a three-phase a.c. 
voltage of about 400 V shall be applied to three 
conductors, any additional conductors being 
connected to the neutral.                                
During the test no open-circuit in any core or 
short-circuit between cores shall occur.                   
After the test, any sheath on cords having three 
or more cores shall be removed. The cord, or the 
laid up cores, shall then withstand the voltage test 
specified in Subclause 8.2 or 8.3 as appropriate, 
but with a test voltage not exceeding 2000 V. 
TABLE 1, TABLE 2, FIGURES 4 and  5, see the   
CB BULLETIN 
 Noted 
 
  
 
TRF No.: I60065__C 
 
 
page 32 of 32 
Ref.No.: 313603 
IEC 60065 
Cl. 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
 
National differences  KOREA 
IEC 60065, 6
th
 edition 
 
CB Bulletin 105A / KR 03 I 
 
 
5.101 Addition 
Other marking; 
Wording “            “ ( See the CB Bulletine) or an 
information regulated in IEC Publication 60417 
giving high voltage warning to layman shall be 
marked, if an apparatus contains a part more 
than 600 volts. 
  
15.1.1 
Plugs for the connection of the apparatus to the 
supply mains and socket outlets for providing 
mains power to other apparatus shall comply with 
the Korean requirements (KSC 8300 and 8305). 
 P 
31 
Radio frequency Interference 
The apparatus shall comply with the relevant 
CISPR requirements. (EMC=EMI + EMS) 
  