page 27 of 32 
Ref.No.: 313603 
IEC 60065 
Cl. 
Requirement - Test 
Result - Remark 
Verdict 
 
 
ZB 
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS 
 
2.6.1 
DK: certain types of Class 
Ι apparatus, see 15.1.1, 
may be provided with a plug not establishing 
earthing continuity when inserted in Danish socket-
outlets 
 N 
15.1.1 
DK: mains cord for single-phase equipment having 
a rated current not exceeding 10 A shall be 
provided with a plug according to Heavy Current 
Regulations Section 107-2-D1 
 N 
 
DK: Class 
Ι equipment with socket-outlets with 
earthing contact, or which are intended to be used 
in locations where protection against indirect 
contact is required shall be provided with a plug in 
compliance with Standard Sheet DK 2-1a 
 N 
 
DK: socket-outlets for providing power to Class 
ΙΙ 
equipment with a  rated current of 2.5 A shall have 
dimensions according to the drawing on page 131 
of EN 60065:98 other dimensions shall be to 
IEC 60083 Standard Sheet C 1a for portable 
socket-outlets 
 N 
 
DK: mains socket-outlets with earthing contact 
shall comply with Heavy Current Regulations 
Section 107-2-D1, Standard Sheet DK 1-3a, 
DK 1-5a or DK 1-7a 
 N 
 
GB: equipment fitted with a flexible cable or cord 
provided with a 13A BS 1363 plug as in Statutory 
Instrument 1768:94 
Approved plug and cord will be 
provided in the end product. 
 
IE: equipment fitted with a flexible cable or cord 
provided with a 13 A plug in accordance with 
Statutory Instrument 525:97 
 P 
 
NO: mains socket-outlets on Class 
ΙΙ equipment meet CEE Publication 7 with the 
following amendments: 
 
- dimensions 2.5 A, 250 V socket-outlets shall 
comply with Standard Sheet 1 page 132 of 
EN 60065:98 
 N 
 
- mechanical strength 2.5 A, 250 V socket-outlets 
tested as specified in EN 60065, 12.1.3 
 N 
 
- protecting rim also tested 
 
B.5.4.1 
NO: marking required for equipment connected to 
a communications network other than the public 
telecommunications network, where separation 
between the mains and the network relies upon a 
safety earth connection 
 N 
 
 
TRF No.: I60065__C 
 
 
page 28 of 32 
Ref.No.: 313603 
IEC 60065 
Cl. 
Requirement - Test 
Result - Remark 
Verdict 
 
 
 
NO: marking to state equipment must be 
connected to an earthed mains socket-outlet 
 N 
 
SE: marking required on equipment connected to 
a telecommunication network, where separation 
between the mains and the network relies on 
connection to protective earth 
 N 
 
SE: marking to state equipment must be 
connected to an earthed mains socket-outlet 
 N 
B.8.1 
DK: method b) of 8.1 is permitted only for 
permanently connected equipment 
 N 
 
NO: method b) of 8.1 is not permitted. Double or 
reinforced insulation is required between parts 
connected to the mains and parts connected to the 
public telecommunications network 
 N 
B.14.12 
DK: surge suppressors between 
telecommunications network and accessible parts 
permitted only for permanently connected 
equipment 
 N 
 
NO: surge suppressors between TNV circuits and 
accessible parts of Class 
Ι equipment permitted 
only if the equipment is marked stating it must be 
connected to an earthed mains socket-outlet 
 N 
 
SE: surge suppressors between TNV circuits and 
accessible parts of Class 
Ι equipment permitted 
only if the equipment is marked stating it must be 
connected to an earthed mains socket-outlet, the 
marking text is: "Apparaten skall anslutas till jordat 
uttag" 
 N 
 
 
TRF No.: I60065__C 
 
 
page 29 of 32 
Ref.No.: 313603 
IEC 60065 
Cl. 
Requirement - Test 
Result - Remark 
Verdict 
 
 
ZC 
ANNEX ZC TO EN 60065, A-DEVIATIONS 
 
DE: additional markings required in German language: 
 
- cathode ray tubes with an accelerating voltage 
between 20 kV and 30 kV (marking on the tube) 
 N 
 
- TV receivers whose picture tube has an 
accelerating voltage between 20 kV and 30 kV 
 N 
 
- TV receivers whose picture tube has an 
accelerating voltage greater than 30 kV 
 N 
 
- TV receivers whose picture tube has an 
accelerating voltage less than 20 kV 
 N 
5.1 
IT: additional markings on the outside of the TV 
receiver in Italian language 
 N 
 
IT: user instructions in Italian language including a 
conformity declaration 
 N 
 
IT: certification number on the back cover 
 
6.1 DE: 
ionizing 
radiation from TV receivers not 
exceeding 1 
µSv/h (= 7.2 pA/kg = 0.1 mR/h) at 
10 cm 
 N 
 
 
TRF No.: I60065__C 
 
 
page 30 of 32 
Ref.No.: 313603 
IEC 60065 
Cl. 
Requirement - Test 
Result - Remark 
Verdict 
 
National differences for Singapore 
(These differences are taken from IEC 60065:1993 and adopted to IEC 60065:1998)
 
 
 
IEC 60065: 1998 
Clauses:  4, 7, 9, 10 and 16.                                                                                                              
 
 
Throughout the standard, whenever the words "white pine board" appear, insert 
the words "or plywood board" to it. 
Noted 
 
SS143 Amendment No. 1 and No. 2 
 
4.1.3 
(4.1.3)* 
Delete "45 % to 75 %" and insert 65 ± 5 %. 
75% maximum in IEC 60065: 
1998 
7.1 
(7.1) 
Resistance to heat without external forces. 
Adopt the temperature specified for the tropical 
conditions. 
 P 
8.6 
(9.3.4) 
Delete the note " A Quality Assessment System 
for capacitors complying with Subclause 14.2 is 
under consideration in the IEC". 
This is not in IEC 60065:1998. 
Noted 
10.2 
(10.2) 
Humidity treatment 
Adopt the testing conditions designed for tropical 
conditions. 
120h at a relative humidity of 
93% 
16 
(16) 
External flexible cords 
Delete "IEC Publication 60227: Polyvinyl Chloride 
Insulated Cables of Rated Voltages up to and 
Including 450/750 V and IEC publication 60245: 
Rubber insulated Cables of rated up to and 
including 450/750 V " and insert "Singapore 
Standard 236: Flexible Cords", whenever they 
appear in this clause. 
Delete "CEE Publication 13, CEE Publication 2 
and IEC Publication 60173: Colours of the Cores 
of Flexible Cables and Cords" whenever they 
appear in this clause. 
 Noted 
16.2 
(16.2) 
Delete the notes in small print and insert  "A 
nominal cross-sectional area of  0.75 mm² will 
satisfy this requirement". 
This is not in IEC 60065:1998. 
Noted 
 
* in parenthesis: clauses acc. to IEC 60065:1993 
 
 
TRF No.: I60065__C 
Page of 54