Harman Kardon SUB-TS 11 EMC - CB Certificate ▷ View online
page 3 of 32
Ref.No.:313603
Copy of marking
TRF No.: I60065__C
page 4 of 32
Ref.No.:313603
Speaker terminal with blocking plug
Note: The picture shows that the high level IN and OUT terminals will be securely plugged to prevent
insertion of “banana” plug according to 15.1.2.
insertion of “banana” plug according to 15.1.2.
TRF No.: I60065__C
page 5 of 32
Ref.No.: 313603
IEC 60065
Cl.
Requirement - Test
Result - Remark
Verdict
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ................................. : Class II
P
4
GENERAL CONDITIONS OF TESTS
4.1.4 Ventilation
instructions
require the use of the test
box
No P
5 MARKING
Comprehensible and easily discernible
P
Permanent durability against water and petroleum
spirit
spirit
P
5.1 Identification,
maker, model ................................... : harman/kardon ,
SUB – TS11
P
Class
ΙΙ symbol
P
Rated
supply
voltage and symbol .......................... : AC 220-240V , 50/60Hz
P
Rated current or power consumption .................... : 300 W
N
5.2 Earth
terminal
N
Hazardous live terminals
N
Supply output terminals (other than mains)
N
5.3
Use of triangle with exclamation mark
P
5.4
Instructions for use
5.4.1
Mains powered equipment not exposed to dripping
or splashing
or splashing
P
Hazardous live terminals, instructions for wiring
N
Instructions for replacing lithium battery
N
Explanation of marking of the manually operated
mechanical switch (MOMS)
mechanical switch (MOMS)
P
5.4.2
Instructions for permanently connected equipment
N
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation
≤ 36 pA/kg (0.5 mR/h)
N
6.2
Laser radiation, emission limits to IEC 60825 ....... :
N
Emission limits under fault conditions
N
TRF No.: I60065__C
page 6 of 32
Ref.No.: 313603
IEC 60065
Cl.
Requirement - Test
Result - Remark
Verdict
7
HEATING UNDER NORMAL OPERATING CONDITIONS (See appended table)
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
P
7.1.1
Temperature rise of accessible parts
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
P
7.1.4
Temperature rise of windings
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150 ºC
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150 ºC
Separately approved
components.
components.
P
8 CONSTRUCTIONAL
REQUIREMENTS
WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
PCB Noted
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Tools are required.
N
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
Not used.
P
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
P
8.5
Class
Ι equipment
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N
Capacitors bridging basic insulation complying with
14.2.1a
14.2.1a
N
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N
Class
ΙΙ equipment and Class ΙΙ constructions
within Class
Ι equipment
N
TRF No.: I60065__C