DOWNLOAD Harman Kardon SOUNDSTICKS III (serv.man2) Service Manual ↓ Size: 2.1 MB | Pages: 85 in PDF or view online for FREE

Model
SOUNDSTICKS III (serv.man2)
Pages
85
Size
2.1 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
soundsticks-iii-sm2.pdf
Date

Harman Kardon SOUNDSTICKS III (serv.man2) EMC - CB Certificate ▷ View online

 
 
- Page 7 of 48 - 
 
 
 Report 
No. 
158002 
 
 
TRF No.:IECEN60950_1C 
 
 
Copy of marking plates:   
 
SoundStricks II: 
 
 
SoundStricks III: 
 
 (The above label is a draft of an artwork for marking plate pending approval by National certification 
Bodies and it shall not be affixed to products prior to such an approval.)
 
 
 
 
List of attachments: 
 
1. Main Test report (48 pages) 
2. Photos (2 pages) 
3. Australian/New Zealand  differences (8 pages) 
4. Canadian differences (6 pages) 
5. Korean differences (1 page) 
6. Singapore differences (3 pages) 
7. US differences (7 pages) 
8. Chinese differences (1 page) 
9. Japanese differences (6 pages)  
10. Israeli differences (1 page)  
11. AC/DC adapter CB certificate (Cert. No. SE-63879) and Test Report (Ref. No. TP10110227-ST)(106 
pages) from Intertek Testing Services Taiwan Ltd. 
 
 
 
 
 
- Page 8 of 48 - 
 
 
 Report 
No. 
158002 
 
 
TRF No.:IECEN60950_1C 
 
 
Test item particulars
 .................................................. :  
Equipment mobility .................................................... : [X] movable     [] hand-held       [] transportable 
[] stationary  [] for building-in  [] direct plug-in 
Connection to the mains ........................................... : []  pluggable equipment   [] type A   [] type B 
[] permanent connection 
[] detachable power supply cord      
[] non-detachable power supply cord 
[X] not directly connected to the mains 
Operating condition ................................................... : [X]  continuous 
[] rated operating / resting time:  
Access location  ........................................................ : [X] operator accessible 
[] restricted access location 
Over voltage category (OVC)  ................................... : [X] OVC I     [] OVC II     [] OVC III     [] OVC IV 
[] other: N/A 
Mains supply tolerance (%) or absolute mains supply 
values  ....................................................................... : N/A   
Tested for IT power systems  .................................... : [] Yes     [] No  
IT testing, phase-phase voltage (V)  ......................... : N/A 
Class of equipment  ................................................... : [] Class I     [] Class II     [X] Class III  
[] Not classified  
Considered current rating (A)  ................................... : N/A  
Pollution degree (PD)  ............................................... : [] PD 1     [X] PD 2     [] PD 3 
IP protection class  .................................................... : IP20  
Altitude during operation (m)  .................................... : ≤ 2000m: 
Altitude of test laboratory (m)  ................................... : <  2000m: 
Mass of equipment (kg)  ............................................ : Subwoofer: 2.0kg  
Satellite speaker: 0.6kg each  
 
Dimension:  
Subwoofer: 23.3 cm wide x 26 cm high  
Satellite speaker: 8.3 cm wide x 25.3 cm high 
 
 
 
- Page 9 of 48 - 
 
 
 Report 
No. 
158002 
 
 
TRF No.:IECEN60950_1C 
 
 
Possible test case verdicts: 
 
- test case does not apply to the test object ................. : N/A 
- test object does meet the requirement ....................... : P  (Pass) 
- test object does not meet the requirement ................. : F  (Fail) 
Testing ........................................................................... :  
Date of receipt of test item ............................................ : December, 2010 
Date(s) of performance of tests .................................... : December, 2010 
 
 
 
- Page 10 of 48 - 
 
 
 Report 
No. 
158002 
 
 
TRF No.:IECEN60950_1C 
 
 
General remarks: 
The test results presented in this report relate only to the object tested. 
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
”(See Enclosure #)” refers to additional information appended to the report. 
”(See appended table)” refers to a table appended to the report. 
Note: This TRF includes EN Group Differences together with National Differences and Special 
National Conditions, if any.  All Differences are located in the Appendix to the main body of this TRF.
 
Throughout this report a point is used as the decimal separator. 
General product information:
  
 
The EUT is a computer stereo system powered by a detachable certified limited power source adapter with 
a specialized input connector. The adaptor refer to list of critical components.  
 
The EUT is provided with an HB (Flame class) enclosure.  
 
Maximum recommended ambient (Tmra) for product: 25°C 
 
Circuit characteristics: No connection to mains, the equipment contains secondary (SELV). 
 
Normal load:  
Supplied with 1KHz(Satellite) and 100Hz(Subwoofer) sinusoidal input signal in computer speaker system, 
tested by 1/8 non-clipped output power, if not specified. 
 
Model Difference:  
The model SoundSticks III is identical with SoundSticks II except for the color of the power indicator LED. 
 
1.1.2 - Additional requirements: 
Exposure to extreme temperatures, excessive dust, moisture or vibration; to flammable gases; to corrosive 
or explosive atmospheres: 
This equipment is intended to operate in a "normal" environment (Offices and homes). 
 
Electromedical equipment connected to the patient: 
This equipment is not an electromedical equipment intended to be physically connected to a patient. 
 
Equipment used in vehicles, ships or aircrafts, in tropical countries, or at elevations > 2000m: 
This equipment is intended to operate in a "normal" environment (Offices and homes). 
 
 
Page of 85
Display

Click on the first or last page to see other SOUNDSTICKS III (serv.man2) service manuals if exist.