Harman Kardon SOUNDSTICKS III (serv.man2) EMC - CB Certificate ▷ View online
- Page 11 of 48 -
Report
No.
158002
TRF No.:IECEN60950_1C
IEC/EN 60950-1
Clause
Requirement + Test
Result – Remark
Verdict
1 GENERAL
—
1.5 Components
—
1.5.1 General
P
Comply with IEC 60950-1 or relevant component
standard
standard
(see appended table 1.5.1)
P
1.5.2
Evaluation and testing of components
Certified components are
used in accordance with their
ratings, certifications and
they comply with applicable
parts of this standard.
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of
IEC 60950-1 and the relevant
component standard.
Components, for which no
relevant IEC-standard exists,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
used in accordance with their
ratings, certifications and
they comply with applicable
parts of this standard.
Components not certified are
used in accordance with their
ratings and they comply with
applicable parts of
IEC 60950-1 and the relevant
component standard.
Components, for which no
relevant IEC-standard exists,
have been tested under the
conditions occurring in the
equipment, using applicable
parts of IEC 60950-1.
P
1.5.3
Thermal controls
No thermal controls.
N/A
1.5.4
Transformers
No isolated transformer in the
equipment.
equipment.
N/A
1.5.5
Interconnecting cables
SELV circuit only
P
1.5.6
Capacitors bridging insulation
No primary circuit.
N/A
1.5.7
Resistors bridging insulation
No such components
bridging insulation.
bridging insulation.
—
1.5.7.1
Resistors bridging functional, basic or
supplementary insulation
supplementary insulation
N/A
1.5.7.2
Resistors bridging double or reinforced insulation
between a.c. mains and other circuits
between a.c. mains and other circuits
N/A
1.5.7.3
Resistors bridging double or reinforced insulation
between a.c. mains and antenna or coaxial cable
between a.c. mains and antenna or coaxial cable
N/A
1.5.8
Components in equipment for IT power systems
The equipment is regarded
as Class III.
as Class III.
N/A
1.5.9
Surge suppressors
No such components.
N/A
- Page 12 of 48 -
Report
No.
158002
TRF No.:IECEN60950_1C
IEC/EN 60950-1
Clause
Requirement + Test
Result – Remark
Verdict
1.5.9.1 General
—
1.5.9.2
Protection of VDRs
—
1.5.9.3
Bridging of functional insulation by a VDR
N/A
1.5.9.4
Bridging of basic insulation by a VDR
N/A
1.5.9.5
Bridging of supplementary, double or reinforced
insulation by a VDR.
insulation by a VDR.
N/A
1.6 Power
interface
1.6.1
AC power distribution systems
The equipment is regarded
as Class III.
as Class III.
—
1.6.2 Input
current
(see appended table 1.6.2)
P
1.6.3
Voltage limit of hand-held equipment
The equipment is not hand-
held.
held.
N/A
1.6.4
Neutral conductor
The equipment is regarded
as Class III.
as Class III.
N/A
1.7
Marking and instructions
1.7.1
Power rating
The required marking is
located on the outside
surface of the equipment.
located on the outside
surface of the equipment.
P
Rated voltage(s) or voltage range(s) (V) ............... :
16Vdc P
Symbol for nature of supply, for d.c. only ............... :
IEC 60417-1, symbol No.
5031, is used.
5031, is used.
P
Rated frequency or rated frequency range (Hz) .... :
DC supplied.
P
Rated
current
(mA or A) ........................................ :
1.5A P
Manufacturer’s name or trade-mark or identification
mark ....................................................................... :
mark ....................................................................... :
harman/kardon P
Model
identification
or type reference ................... :
SoundSticks II;
SoundSticks III
P
Symbol for Class II equipment only ....................... :
The equipment is regarded
as Class III.
as Class III.
N/A
Other markings and symbols ................................. :
The additional marking plate
does not give rise to
misunderstandings.
does not give rise to
misunderstandings.
P
1.7.2
Safety instructions and marking
Equipment with an enclosure
made of HB-material marked
model name of adapter which
used for this apparatus in
marking plate.
made of HB-material marked
model name of adapter which
used for this apparatus in
marking plate.
P
- Page 13 of 48 -
Report
No.
158002
TRF No.:IECEN60950_1C
IEC/EN 60950-1
Clause
Requirement + Test
Result – Remark
Verdict
1.7.2.1 General
Considered.
—
1.7.2.2
Disconnect devices
Class III equipment.
N/A
1.7.2.3 Overcurrent
protective device
Class III equipment.
N/A
1.7.2.4
IT power distribution systems
Class III equipment.
—
1.7.2.5
Operator access with a tool
No operator access area
requires a tool to gain
access.
requires a tool to gain
access.
N/A
1.7.2.6
Ozone
The equipment does not
produce Ozone.
produce Ozone.
N/A
1.7.3
Short duty cycles
The equipment is intended
for continuous operation.
for continuous operation.
N/A
1.7.4 Supply
voltage adjustment ................................... :
No voltage selector.
N/A
Methods and means of adjustment; reference to
installation instructions ......................................... :
installation instructions ......................................... :
N/A
1.7.5 Power
outlets
on the equipment ........................... :
No standard power outlet.
N/A
1.7.6
Fuse identification (marking, special fusing
characteristics, cross-reference) .......................... :
characteristics, cross-reference) .......................... :
No fuses.
N/A
1.7.7
Wiring terminals
Refer below.
—
1.7.7.1 Protective
earthing and bonding terminals ........... :
Class III equipment.
N/A
1.7.7.2
Terminals for a.c. mains supply conductors
Class III equipment.
N/A
1.7.7.3
Terminals for d.c. mains supply conductors
The equipment is not
supplied from d.c mains.
supplied from d.c mains.
N/A
1.7.8
Controls and indicators
Refer below.
—
1.7.8.1 Identification,
location and marking ...................... :
No function of controls
affecting safety.
affecting safety.
N/A
1.7.8.2 Colours ................................................................ :
For functional indication a
LED lights when the
equipment is operating.
LED lights when the
equipment is operating.
P
1.7.8.3
Symbols according to IEC 60417 ......................... :
There are no switches in the
equipment.
equipment.
N/A
1.7.8.4
Markings using figures ....................................... :
No such controls.
N/A
1.7.9
Isolation of multiple power sources ..................... :
Class III equipment. N/A
1.7.10
Thermostats and other regulating devices .......... :
No thermostats or other
regulating devices.
regulating devices.
N/A
1.7.11
Durability
The marking withstands
required tests.
required tests.
P
1.7.12
Removable parts
No marking is placed on
removable parts.
removable parts.
P
- Page 14 of 48 -
Report
No.
158002
TRF No.:IECEN60950_1C
IEC/EN 60950-1
Clause
Requirement + Test
Result – Remark
Verdict
1.7.13 Replaceable
batteries .......................................... :
N/A
Language(s)
........................................................ :
—
1.7.14
Equipment for restricted access locations ............ :
Equipment not intended for
installation in RAL.
installation in RAL.
N/A
2
PROTECTION FROM HAZARDS
2.1
Protection from electric shock and energy hazards
2.1.1
Protection in operator access areas
Class III equipment.
—
2.1.1.1
Access to energized parts
Class III equipment, supplied
from a LPS.
from a LPS.
N/A
Test by inspection .................................................. :
N/A
Test with test finger (Figure 2A) ............................ :
N/A
Test with test pin (Figure 2B) ................................ :
N/A
Test with test probe (Figure 2C) ............................ :
No TNV circuit in the
equipment.
equipment.
N/A
2.1.1.2
Battery compartments
No TNV circuits in the
equipment.
equipment.
N/A
2.1.1.3
Access to ELV wiring
No internal wiring at ELV
accessible to the operator.
accessible to the operator.
N/A
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)
distance through insulation (mm)
N/A
2.1.1.4
Access to hazardous voltage circuit wiring
Class III equipment.
N/A
2.1.1.5 Energy hazards ..................................................... :
Class III equipment, supplied
from a LPS.
from a LPS.
N/A
2.1.1.6 Manual
controls
No
shafts of knobs etc.
N/A
2.1.1.7
Discharge of capacitors in equipment
Class III equipment.
N/A
Measured voltage (V); time-constant (s) ................ :
—
2.1.1.8
Energy hazards – d.c. mains supply
Not connected to DC mains
supply.
supply.
N/A
a) Capacitor connected to the d.c. mains supply .. :
N/A
b) Internal battery connected to the d.c. mains
supply .................................................................... :
supply .................................................................... :
N/A
2.1.1.9 Audio
amplifiers ..................................................... :
Accessible terminal is SELV
only.
only.
P
2.1.2
Protection in service access areas
Class III equipment, SELV
circuit only
circuit only
N/A
2.1.3
Protection in restricted access locations
Equipment not intended for
installation in RAL.
installation in RAL.
N/A