- Page 19 of 48 -
Report
No.
158002
TRF No.:IECEN60950_1C
IEC/EN 60950-1
Clause
Requirement + Test
Result – Remark
Verdict
3.4
Disconnection from the mains supply
3.4.1 General
requirement
Class III equipment.
N/A
3.4.2 Disconnect
devices
N/A
3.4.3
Permanently connected equipment
N/A
3.4.4
Parts which remain energized
N/A
3.4.5
Switches in flexible cords
N/A
3.4.6
Number of poles – single-phase and d.c.
equipment
equipment
N/A
3.4.7
Number of poles - three-phase equipment
N/A
3.4.8
Switches as disconnect devices
N/A
3.4.9
Plugs as disconnect devices
N/A
3.4.10 Interconnected
equipment
N/A
3.4.11
Multiple power sources
N/A
3.5
Interconnection of equipment
3.5.1 General
requirements
Considered.
—
3.5.2
Types of interconnection circuits .......................... :
SELV circuit.
P
3.5.3
ELV circuits as interconnection circuits
No ELV.
N/A
3.5.4
Data ports for additional equipment
Class III equipment, power
from a SELV LPS source.
from a SELV LPS source.
P
4 PHYSICAL
REQUIREMENTS
4.1 Stability
N/A
Angle of 10
Mass < 7kg.
N/A
Test
force (N) ......................................................... :
The unit is not floor-standing.
N/A
4.2 Mechanical
strength
4.2.1
General
Class III equipment, power
from a SELV LPS source. No
shock or energy hazards, no
test considered necessary.
from a SELV LPS source. No
shock or energy hazards, no
test considered necessary.
N/A
4.2.2
Steady force test, 10 N
N/A
4.2.3
Steady force test, 30 N
N/A
4.2.4
Steady force test, 250 N
N/A
4.2.5 Impact
test
—
- Page 20 of 48 -
Report
No.
158002
TRF No.:IECEN60950_1C
IEC/EN 60950-1
Clause
Requirement + Test
Result – Remark
Verdict
Fall
test
N/A
Swing
test
N/A
4.2.6 Drop
test;
height (mm) ........................................... :
N/A
4.2.7
Stress relief test
N/A
4.2.8
Cathode ray tubes
CRT(s) not used in the
equipment.
equipment.
N/A
Picture tube separately certified ............................ :
N/A
4.2.9
High pressure lamps
No high pressure lamps in
the equipment.
the equipment.
N/A
4.2.10
Wall or ceiling mounted equipment; force (N) ....... :
Not intended to be mounted
on a wall or ceiling.
on a wall or ceiling.
N/A
4.3
Design and construction
4.3.1
Edges and corners
All edges and corners are
rounded and/or smoothed.
rounded and/or smoothed.
P
4.3.2
Handles and manual controls; force (N) ............. :
No knobs, grips, handles,
lever etc.
lever etc.
N/A
4.3.3
Adjustable controls
No hazardous adjustable
controls.
controls.
N/A
4.3.4
Securing of parts
No loosening of parts
impairing creepage distances
or clearances is likely to
occur.
impairing creepage distances
or clearances is likely to
occur.
P
4.3.5
Connection by plugs and sockets
SELV connectors do not
comply with IEC 60320 or
IEC 60083.
comply with IEC 60320 or
IEC 60083.
P
4.3.6
Direct plug-in equipment
Class III equipment.
N/A
4.3.7
Heating elements in earthed equipment
No heating elements
provided.
provided.
N/A
4.3.8
Batteries
No batteries in the
equipment.
equipment.
N/A
4.3.9
Oil and grease
Insulation is not exposed to
oil, grease etc.
oil, grease etc.
N/A
4.3.10
Dust, powders, liquids and gases
The equipment does not
generate ionizing radiation or
use a laser, and does not
contain flammable liquids or
gases.
generate ionizing radiation or
use a laser, and does not
contain flammable liquids or
gases.
P
4.3.11
Containers for liquids or gases
No containers for liquids or
gases in the equipment.
gases in the equipment.
N/A
- Page 21 of 48 -
Report
No.
158002
TRF No.:IECEN60950_1C
IEC/EN 60950-1
Clause
Requirement + Test
Result – Remark
Verdict
4.3.12
Flammable liquids ................................................. :
The equipment does not
contain flammable liquid.
contain flammable liquid.
N/A
4.3.13 Radiation
Refer
below:
—
4.3.13.1 General
Refer
below:
—
4.3.13.2 Ionizing
radiation
The equipment does not
generate ionizing radiation.
generate ionizing radiation.
N/A
4.3.13.3
Effect of ultraviolet (UV) radiation on materials
The equipment does not
produce significant UV
radiation.
produce significant UV
radiation.
N/A
4.3.13.4
Human exposure to ultraviolet (UV) radiation ...... :
The equipment does not
produce significant UV
radiation.
produce significant UV
radiation.
N/A
4.3.13.5
Laser (including LEDs)
LEDs provided are diffuse.
N/A
4.3.13.6 Other types ........................................................... :
The equipment does not
generate other types of
radiation.
generate other types of
radiation.
N/A
4.4
Protection against hazardous moving parts
N/A
4.4.1
General
No hazardous moving parts.
N/A
4.4.2
Protection in operator access areas .................... :
No hazardous moving parts.
N/A
4.4.3
Protection in restricted access locations ............. :
No intended for installation in
RAL.
RAL.
N/A
4.4.4
Protection in service access areas
No intended for installation in
service access areas.
service access areas.
N/A
4.5 Thermal
requirements
4.5.1 General
See
below.
—
4.5.2
Temperature tests
(see appended table 4.5)
P
Normal load condition per Annex L ..................... :
—
4.5.3
Temperature limits for materials
(see appended table 4.5)
P
4.5.4
Touch temperature limits
(see appended table 4.5)
P
4.5.5
Resistance to abnormal heat ............................... :
N/A
4.6
Openings in enclosures
4.6.1
Top and side openings
No top and side openings.
P
Dimensions
(mm) ................................................ :
—
4.6.2
Bottoms of fire enclosures
No bottom openings.
P
- Page 22 of 48 -
Report
No.
158002
TRF No.:IECEN60950_1C
IEC/EN 60950-1
Clause
Requirement + Test
Result – Remark
Verdict
Construction of the bottomm, dimensions (mm) :
—
4.6.3
Doors or covers in fire enclosures
No doors or covers provided
P
4.6.4
Openings in transportable equipment
The unit is not regards as
transportable equipment.
transportable equipment.
N/A
4.6.4.1
Constructional design measures
No openings in equipment.
N/A
Dimensions
(mm) ................................................ :
N/A
4.6.4.2
Evaluation measures for larger openings
N/A
4.6.4.3
Use of metallized parts
No used.
N/A
4.6.5
Adhesives for constructional purposes
No adhesive used for
constructional purposes.
constructional purposes.
N/A
4.7
Resistance to fire
4.7.1
Reducing the risk of ignition and spread of flame
Method 1 is used.
P
Method 1, selection and application of components
wiring and materials
wiring and materials
(see appended table 1.5.1)
P
Method 2, application of all of simulated fault
condition tests
condition tests
N/A
4.7.2
Conditions for a fire enclosure
Refer below.
—
4.7.2.1
Parts requiring a fire enclosure
Supplied by certified limited
power source adaptor and all
components are mounted on
V-1 or better material, no fire
enclosure is required.
power source adaptor and all
components are mounted on
V-1 or better material, no fire
enclosure is required.
N/A
4.7.2.2
Parts not requiring a fire enclosure
Supplied by certified limited
power source adaptor and all
components are mounted on
V-1 or better material, no fire
enclosure is required.
power source adaptor and all
components are mounted on
V-1 or better material, no fire
enclosure is required.
P
4.7.3 Materials
P
4.7.3.1
General
Components and materials
have adequate flammability
classification. (see appended
table 1.5.1.)
have adequate flammability
classification. (see appended
table 1.5.1.)
P
4.7.3.2
Materials for fire enclosures
Fire enclosure not required.
Refer to 4.7.2.
Refer to 4.7.2.
N/A
4.7.3.3
Materials for components and other parts outside
fire enclosures
fire enclosures
Fire enclosure not required.
Refer to 4.7.2.
Refer to 4.7.2.
N/A
4.7.3.4
Materials for components and other parts inside fire
enclosures
enclosures
Fire enclosure not required.
Refer to 4.7.2.
Refer to 4.7.2.
N/A