Harman Kardon SOUNDSTICKS III (serv.man2) EMC - CB Certificate ▷ View online
- Page 35 of 48 -
Report
No.
158002
TRF No.:IECEN60950_1C
6.1.2.1
In Finland, Norway and Sweden, add the following text between the first and
second paragraph of the compliance clause:
If this insulation is solid, including insulation forming part of a component, it shall at
least consist of either
-
second paragraph of the compliance clause:
If this insulation is solid, including insulation forming part of a component, it shall at
least consist of either
-
two layers of thin sheet material, each of which shall pass the electric
strength test below, or
-
one layer having a distance through insulation of at least 0,4 mm, which
shall
pass the electric strength test below.
If this insulation forms part of a semiconductor component (e.g. an optocoupler),
there is no distance through insulation requirement for the insulation consisting of
an insulating compound completely filling the casing, so that CLEARANCES and
CREEPAGE DISTANCES do not exist, if the component passes the electric
strength test in accordance with the compliance clause below and in addition
-
there is no distance through insulation requirement for the insulation consisting of
an insulating compound completely filling the casing, so that CLEARANCES and
CREEPAGE DISTANCES do not exist, if the component passes the electric
strength test in accordance with the compliance clause below and in addition
-
passes the tests and inspection criteria of 2.10.11 with an electric strength
test of 1,5 kV multiplied by 1,6 (the electric strength test of 2.10.10 shall be
performed using 1,5 kV), and
-
is subject to ROUTINE TESTING for electric strength during manufacturing,
using a test voltage of 1,5 kV.
It is permitted to bridge this insulation with a capacitor complying with
EN 132400:1994, subclass Y2.
A capacitor classified Y3 according to EN 132400:1994, may bridge this insulation
under the following conditions:
-
EN 132400:1994, subclass Y2.
A capacitor classified Y3 according to EN 132400:1994, may bridge this insulation
under the following conditions:
-
the insulation requirements are satisfied by having a capacitor classified Y3
as defined by EN 132400, which in addition to the Y3 testing, is tested with
an impulse test of 2,5 kV defined in EN 60950-1:2006, 6.2.2.1;
-
the additional testing shall be performed on all the test specimens as
described in EN 132400;
-
the impulse test of 2,5 kV is to be performed before the endurance test in
EN 132400, in the sequence of tests as described in EN 132400.
N/A
6.1.2.2
In Finland, Norway and Sweden, the exclusions are applicable for
PERMANENTLY CONNECTED EQUIPMENT, PLUGGABLE EQUIPMENT TYPE
B and equipment intended to be used in a RESTRICTED ACCESS LOCATION
where equipotential bonding has been applied, e.g. in a telecommunication centre,
and which has provision for a permanently connected PROTECTIVE EARTHING
CONDUCTOR and is provided with instructions for the installation of that conductor
by a SERVICE PERSON.
PERMANENTLY CONNECTED EQUIPMENT, PLUGGABLE EQUIPMENT TYPE
B and equipment intended to be used in a RESTRICTED ACCESS LOCATION
where equipotential bonding has been applied, e.g. in a telecommunication centre,
and which has provision for a permanently connected PROTECTIVE EARTHING
CONDUCTOR and is provided with instructions for the installation of that conductor
by a SERVICE PERSON.
N/A
7.2
In Finland, Norway and Sweden, for requirements see 6.1.2.1 and 6.1.2.2 of this
annex.
The term TELECOMMUNICATION NETWORK in 6.1.2 being replaced by the term
CABLE DISTRIBUTION SYSTEM.
annex.
The term TELECOMMUNICATION NETWORK in 6.1.2 being replaced by the term
CABLE DISTRIBUTION SYSTEM.
N/A
7.3
In Norway and Sweden, for requirements see 1.2.13.14 and 1.7.2.1 of this annex.
N/A
7.3
In Norway, for installation conditions see EN 60728-11:2005.
N/A
ZC
A-DEVIATIONS (informative)
—
- Page 36 of 48 -
Report
No.
158002
TRF No.:IECEN60950_1C
1.5.1
Sweden
(Ordinance 1990:944)
Add the following:
NOTE In Sweden, switches containing mercury are not permitted.
N/A
1.5.1
Switzerland
(Ordinance on environmentally hazardous substances SR 814.081,
Annex 1.7, Mercury - Annex 1.7 of SR 814.81 applies for mercury.)
Add the following:
Add the following:
NOTE In Switzerland, switches containing mercury such as thermostats, relays and level
controllers are not allowed.
controllers are not allowed.
N/A
1.7.2.1
Denmark
(Heavy Current Regulations)
Supply cords of CLASS I EQUIPMENT, which is delivered without a plug, must be
provided with a visible tag with the following text:
provided with a visible tag with the following text:
Vigtigt!
Lederen med grøn/gul isolation
må kun tilsluttes en klemme mærket
eller
If essential for the safety of the equipment, the tag must in addition be provided
with a diagram, which shows the connection of the other conductors, or be
provided with the following text:
“For tilslutning af de øvrige ledere, se medfølgende installationsvejledning.”
with a diagram, which shows the connection of the other conductors, or be
provided with the following text:
“For tilslutning af de øvrige ledere, se medfølgende installationsvejledning.”
N/A
1.7.2.1
Germany
(Gesetz über technische Arbeitsmittel und Verbraucherprodukte (Geräte-
und Produktsicherheitsgesetz – GPSG) [Law on technical labour equipment and
consumer products], of 6th January 2004, Section 2, Article 4, Clause (4), Item 2).
If for the assurance of safety and health certain rules during use, amending or
maintenance of a technical labour equipment or readymade consumer product are
to be followed, a manual in German language has to be delivered when placing the
product on the market.
Of this requirement, rules for use even only by SERVICE PERSONS are not
exempted.
consumer products], of 6th January 2004, Section 2, Article 4, Clause (4), Item 2).
If for the assurance of safety and health certain rules during use, amending or
maintenance of a technical labour equipment or readymade consumer product are
to be followed, a manual in German language has to be delivered when placing the
product on the market.
Of this requirement, rules for use even only by SERVICE PERSONS are not
exempted.
N/A
1.7.5
Denmark
(Heavy Current Regulations)
With the exception of CLASS II EQUIPMENT provided with a socket outlet in
accordance with the Heavy Current Regulations, Section 107-2-D1, Standard
Sheet DK 1-4a, CLASS II EQUIPMENT shall not be fitted with socket-outlets for
providing power to other equipment.
accordance with the Heavy Current Regulations, Section 107-2-D1, Standard
Sheet DK 1-4a, CLASS II EQUIPMENT shall not be fitted with socket-outlets for
providing power to other equipment.
N/A
1.7.13
Switzerland
(Ordinance on chemical hazardous risk reduction SR 814.81, Annex
2.15 Batteries)
Annex 2.15 of SR 814.81 applies for batteries.
Annex 2.15 of SR 814.81 applies for batteries.
N/A
5.1.7.1
Denmark
(Heavy Current Regulations, Chapter 707, clause 707.4)
TOUCH CURRENT measurement results exceeding 3,5 mA r.m.s. are permitted
only for PERMANENTLY CONNECTED EQUIPMENT and PLUGGABLE
EQUIPMENT TYPE B.
only for PERMANENTLY CONNECTED EQUIPMENT and PLUGGABLE
EQUIPMENT TYPE B.
N/A
- Page 37 of 48 -
Report
No.
158002
TRF No.:IECEN60950_1C
1.5.1
TABLE: List of critical components
P
object/part No.
manufacturer/
trademark
trademark
type/model
technical data
standard
mark(s) of
conformity
conformity
1
)
AC/DC Adapter
2
)
LEADER
ELECTRONICS
INC
ELECTRONICS
INC
NU40-2160150-I3
Input:
100-240Vac,
50/60Hz, 1.2A
Max.
Output:
16V DC, 1.5A
Class II
100-240Vac,
50/60Hz, 1.2A
Max.
Output:
16V DC, 1.5A
Class II
IEC 60950-
1:2ed+A1
EN 60950-
1:2ed+A11+
A1
1:2ed+A1
EN 60950-
1:2ed+A11+
A1
ITS
PCB material
Various
Various
V-0, 105
C
UL796, UL94 UL
Enclosure
Various Various Min HB, min.
3.0mm thick
UL94 UL
Power amplifier
IC (U12)
IC (U12)
Philips
TDA8512J
26 W x 1 Sub
output,
13 W x 2
Satellite output
output,
13 W x 2
Satellite output
IEC 60950-1 Tested in
equipment
Power amplifier
IC (U12)
Alt.)
IC (U12)
Alt.)
Philips
TDA8561Q
24 W x 1 Sub
output,
12 W x 2
Satellite output
output,
12 W x 2
Satellite output
IEC 60950-1 Tested in
equipment
Subwoofer Various
Various
4Ω
IEC 60950-1 Test in the
equip.
Satellite speaker
x 2
x 2
Various Various (4)
8Ω, in
parallel. Nominal
2 Ω
2 Ω
IEC 60950-1 Test in the
equip.
Supplementary information:
1
) An asterisk indicates a mark which assures the agreed level of surveillance
2
) AC/DC adapter (see attached CB certificate (Cert. No. SE-63879) and Test Report (Ref. No.
TP10110227-ST)(106 pages) from Intertek Testing Services Taiwan Ltd.
- Page 38 of 48 -
Report
No.
158002
TRF No.:IECEN60950_1C
1.5.1
TABLE: Opto Electronic Devices
N/A
Manufacturer ............................................... :
Type ............................................................. :
Separately tested ........................................ :
Bridging insulation ....................................... :
External creepage distance ......................... :
Bridging insulation ....................................... :
External creepage distance ......................... :
Internal creepage distance .......................... :
Distance through insulation ......................... :
Tested under the following conditions ......... :
Input ............................................................. :
Output .......................................................... :
Input ............................................................. :
Output .......................................................... :
supplementary information
Click on the first or last page to see other SOUNDSTICKS III (serv.man2) service manuals if exist.