Harman Kardon SB 26 (serv.man3) EMC - CB Certificate ▷ View online
Page 9 of 40
Report No.: ACSCBAV13004
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
8
Constructional requirements with regard to the protection against electric
shock
For SB26 CNTR: Not directly connected to the mains.
For SB26 SUB: See below
shock
For SB26 CNTR: Not directly connected to the mains.
For SB26 SUB: See below
-
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
N/A
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
Not done without a tool.
Pass
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
No hygroscopic material used.
Pass
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the
removal of a cover which can be removed by hand
from parts rendered accessible following the
removal of a cover which can be removed by hand
See CL. 8.6
Pass
8.5
Class I equipment
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
Protective earthing terminal
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
Pass
Double or reinforced insulation between hazardous
live parts and accessible parts
live parts and accessible parts
See appended table 13.
Pass
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
Switching Transformer T541
comply with CL. 14.3.
comply with CL. 14.3.
Pass
Basic insulation bridged by components complying
with 14.3.4.3.
with 14.3.4.3.
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
N/A
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
See appended table 14.
CY502, CY503, CY504 and
CY505.
CY502, CY503, CY504 and
CY505.
Pass
8.7
This clause is void
—
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
N/A
Reinforced
insulation
> 0,4 mm (mm) ....................:
Pass
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
N/A
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Page 10 of 40
Report No.: ACSCBAV13004
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
Pass
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
PVC, 2 x 0.4mm
Pass
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
N/A
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
PVC, 2 x 0.4mm
Pass
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
Secondary: Single insulated,
dressed away from primary.
dressed away from primary.
N/A
8.11
Detaching of wires
Pass
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Pass
Vibration test carried out .........................................: See CL. 12.1.2. Pass
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
N/A
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
No hot parts or sharp edges
around wires.
around wires.
Pass
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
Pass
8.19.1
Disconnect device
Mains plug.
Pass
All-pole switch or circuit breaker with >3mm contact
separation
separation
N/A
8.19.2
Mains switch ON indication
N/A
8.20
Switch not fitted in the mains cord
N/A
8.21
Bridging components comply with clause 14
N/A
8.22
Non-separable thin sheet material
N/A
Page 11 of 40
Report No.: ACSCBAV13004
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
9
Electric shock hazard under normal operating conditions
For SB26 CNTR: Not directly connected to the mains.
For SB26 SUB: See below
For SB26 CNTR: Not directly connected to the mains.
For SB26 SUB: See below
-
9.1
Testing on the outside
Pass
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
N/A
9.1.1.1
a) Open circuit voltages
Pass
b) Touch current measured from terminal devices
using the network in annex D .................................:
using the network in annex D .................................:
U1: 0.854V peak,
U2: 0.217V peak.
U2: 0.217V peak.
Pass
c) Discharge not exceeding 45 μC
<45 μC. Pass
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
No hazardous live parts are
accessible.
accessible.
Pass
9.1.2
No hazardous live shafts of knobs, handles or levers
Pass
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No top ventilation.
N/A
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
Pass
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Pass
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
No pre-set controls.
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s ..................:
of the mains plug; voltage (V) after 2 s ..................:
8.3Vdc (Standby)
16.7Vdc (Standby, with R502
opened)
Rating of R502, R503, R504,
R505: 1MΩ
16.7Vdc (Standby, with R502
opened)
Rating of R502, R503, R504,
R505: 1MΩ
Pass
If C is not greater than 0,1 μF no test needed
0.33μF. N/A
9.1.7
Resistance to external forces
Pass
a) Test probe 11 of IEC 61032 for 10 s (50 N)
Pass
b) Test hook of fig. 4 for 10 s (20 N)
Pass
c) 30 mm diameter test tool for 5 s (100 or 250 N)
Conducted on metal enclosure
fixed amplify board.
fixed amplify board.
Pass
9.2
No hazard after removing a cover by hand
N/A
10 Insulation
requirements
For SB26 CNTR: Not directly connected to the mains.
For SB26 SUB: See below
For SB26 SUB: See below
-
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation .................................................................:
surge test for basic and 4 MΩ min. for reinforced
insulation .................................................................:
N/A
10.2 Humidity
treatment 48 h or 120 h ...........................: 40
°C, 95%, 120h.
Pass
Page 12 of 40
Report No.: ACSCBAV13004
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
10.3
Insulation resistance and dielectric strength between
mains terminals
mains terminals
See appended table 10.3.
Pass
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
BASIC or SUPPLEMENTARY insulation (Class I)
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
See appended table 10.3.
Pass
11 Fault
conditions
-
11.1
No shock hazard under fault condition
For SB26 SUB:
U1: 0.887V peak,
U2: 0.246V peak.
U1: 0.887V peak,
U2: 0.246V peak.
Pass
11.2
Heating under fault condition
Pass
Flames extinguish within 10 seconds
No flames occurred.
N/A
No hazard from softening solder
Pass
Soldered terminations not used as protective
mechanism
mechanism
Pass
11.2.1
Measurement of temperature rises
See appended table 11.2.
Pass
11.2.2
Temperature rise of accessible parts
See appended table 11.2.
Pass
11.2.3
Temperature rise of parts, other than windings and
printed boards, providing electrical insulation
printed boards, providing electrical insulation
See appended table 11.2.
Pass
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
See appended table 11.2.
Pass
11.2.5
Temperature rise of windings
See appended table 11.2.
Pass
11.2.6
Temperature rise of printed boards shall not exceed
the limits of table 3 by max. 100 K for max. 5 min
the limits of table 3 by max. 100 K for max. 5 min
N/A
Printed circuit boards (PCB) classified as V-0
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
Pass
a) Temperature rise of printed circuit boards
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ................:
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ................:
N/A
b) Temperature rise of printed circuit boards
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.7
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
See appended table 11.2.
Pass