Report No.: ACSCBAV13004 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
No. 
Component  Fault  test 
voltage 
(V) 
test 
time 
fuse 
fuse current  
measured (A)
Result 
17 CE543 
S/C 264 10mins F501  0.026
↔0.074 Unit shutdown and cycled, 
recoverable, NCD, NB, NH. 
18 R541 
S/C 264 10mins F501  0.026 
Unit shutdown, recoverable, 
NCD, NB, NH. 
Measured on main board 
19 U701 
pin 2-39 
S/C 264  10mins F501  0.047 
Unit shutdown, recoverable, 
NCD, NB, NH. 
20 Speaker  S/C 264 5hours 
18mins
F501 
0.050 
Unit shutdown, recoverable, 
NCD, NB, NH. 
21 Max. 
non-
clipped 
output 
power 
- 264 
6hours 
54mins
F501 
0.962 
Similar normal operated. 
NCD, NB, NH. 
LIF502 coil: 55.3K 
U541 body: 89.6K 
T541 coil: 78.9K 
PWB near T541: 70.0K 
Heatsink HS1: 99.7K 
Enclosure plastic, outside 
(near power board): 41.7K  
For Soundbar (SB26 CNTR) 
22 
C177 
S/C 
264 
1s 
-- 
Unit shutdown, CD (R13), 
TRSR with two more times, 
NH. 
23 U17 
Pin 29 - 9 
S/C 
264 
10mins -- 
0.593 
Unit power decreased to 
15.66W, recoverable, NCD, 
NH. 
24 U17 
Pin 29 - 31 
S/C 
264 
10mins -- 
0.593 
Unit power decreased to 
15.66W, recoverable, NCD, 
NH. 
25 Low 
frequency 
speaker 
S/C 264  3hours
28mins
-- 
0.593 
Unit power decreased to 
15.66W, recoverable, NCD, 
NH. 
L11 body: 45.9K 
U11 body: 45.3K 
Front enclosure outside near 
PWB: 13.4K 
26 High 
frequency 
speaker 
S/C 264  2hours
5mins
-- 
0.593 
Unit power decreased to 
15.66W, recoverable, NCD, 
NH. 
L11 body: 45.7K 
U11 body: 45.2K 
Front enclosure outside near 
PWB: 11.8K 
Page 30 of 40 
Report No.: ACSCBAV13004 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
No. 
Component  Fault  test 
voltage 
(V) 
test 
time 
fuse 
fuse current  
measured (A)
Result 
27 
USB port 
S/C 
264 
10mins -- 
0.170 
Unit shutdown, recoverable, 
NCD, NH. 
28 Max. 
non-
clipped 
output 
power 
- 264 
6hours
35mins
-- 
3.57 
Unit power increased to 
94.25W, recoverable, NCD, 
NH. 
L11 body: 77.0K 
U11 body: 82.0K 
Front enclosure outside near 
PWB: 42.9K 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (
o
C) .................................. : - 
— 
 
Ambient temperature t2 (
o
C) .................................. : - 
— 
 
13 
TABLES: clearances and creepage distances 
Pass 
Rated supply voltage: 100-240V 
Pollution degree.. : 2 
Material Group.... :  IIIb 
2 N force on internal parts applied: 
Pass 
30 N force on outside of conductive enclosure applied: 
Pass 
 
Location 
Working Voltage
Clearance (mm) 
Creepage (mm)
CTI 
 
V peak
V rms
Min 
Actual 
Min 
Actual
< 175
For Subwoofer (SB26 SUB) 
Circuits conductively connected to the mains (use Tables 8, 9 and 11): see note below. 
Opposite pattern traces before fuse 
F501 on PCB, as basic 
<420 <250  2.0  3.6  2.5  3.6  <175
Pri. fuse F501, pattern traces on 
PCB, as basic 
<420 <250  2.0  3.1  2.5  3.1  <175
Pri. pattern traces to secondary 
pattern traces (near screw trace), as 
reinforced 
<420 <250  4.0  7.3  5.0  7.3  <175
Pri. pattern traces to secondary 
pattern traces (near CY502), as 
reinforced 
<420 <250  4.0  7.2  5.0  7.2  <175
Pri. pattern traces to secondary 
pattern traces (near CY504), as 
reinforced 
<420 <250  4.0  7.3  5.0  7.3  <175
Pri. pattern traces to secondary 
pattern traces (near CY505), as 
reinforced 
<420 <250  4.0  7.4  5.0  7.4  <175
HS1 to side metal chassis, as 
reinforced 
475 
max. 
<250 
(223)
 
4.2 10.2 5.0 >10.2
<175
Primary solder pin to bottom metal 
chassis, as reinforced 
475 
max. 
<250 
(223)
 
4.2 7.5 5.0 >7.5 
<175
Page 31 of 40 
Report No.: ACSCBAV13004 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
Switching transformer T541, core considered as floating. 
Pri. Coil to Core, 
as basic
475 
max. 
<250 
(223)
 
2.1 3.5 2.5 3.5 
<175
Sec. Coil to Core, 
as supplementary
475 
max. 
<250 
(223)
 
2.1 3.5 2.5 3.5 
<175
Pri. pin to Sec. pin via core,
as reinforced
475 
max. 
<250 
(223)
 
4.2 7.0 5.0 7.0 
<175
Sec. pin of CY504 to core,
as reinforced
475 
max. 
<250 
(223)
 
4.2 4.5 5.0 >4.5 
<175
Sec. pin of CY505 to core,
as reinforced
475 
max. 
<250 
(223)
 
4.2 5.0 5.0 >5.0 
<175
Notes: 
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g. antenna signal input), are 
subjected to the requirements for circuits conductively connected to the mains in Tables 8 and 9. 
2. Floating secondary circuits of Class I apparatus which have connector terminals that could be earthed (e.g. antenna signal input), 
are subjected to the requirements for circuits conductively connected to the mains in Tables 8 and 9 unless the floating secondary 
circuit is separated from the primary circuits by an earthed metal screen (e.g. in the power transformer), or the floating secondary 
circuit is connected to earth via a component such as a capacitor. 
3. For insufficient clearances and creepage distances from secondary to secondary circuits and from secondary circuits to earth, see 
Cl. 4.3.1, 4.3.2 and 11.2. 
4. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8, 9 or 10 as required, then 
the value for clearance is used as the minimum creepage distance . 
"Min" = minimum required. 
"Actual = Actual dimensions measured. 
5. Mylat sheet was affixed on side metal chassis. 
 
Page 32 of 40 
Report No.: ACSCBAV13004 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
14 
TABLE: list of critical components and materials 
Pass 
 
Component 
Manufacturer/ 
trademark 
Type/model 
Value / rating 
Standard 
Approval/ 
Reference 
For soundbar (SB26 CNTR) 
AC ADAPTOR  TCL Technoly 
Electronics 
(Huizhou) Co., 
Ltd. 
TNUA2402703 
Input: 100-240V~, 
50/60Hz, 143-
185VA; Output: 
24Vdc, 2.7A. Class 
II, Tma=45℃ 
IEC60065 (7
th
 
ed.)+A1+A2; 
EN60065 (7
th
 
ed.)+A1+A11
+A2+A12 
Issued by 
TUV SUD 
with CB 
Cert. No. 
SG-TN-
02668, CB 
Rpt. No. 
211-400194-
000 
Plastic 
enclosure 
Interchangeable Interchangeable  Min. HB, Min. 70℃  UL94 UL 
For subwoofer (SB26 SUB)
 
Switching 
Transformer  
/ T541 
Huizhou 
Sunshine 
Electronics Co., 
Ltd. 
BCK-AL140 
(36-TRF342-SX0-
E) 
Open, concentric 
winding 
IEC60065 
Tested in 
unit 
Bobbin material  Chang Chun 
Plastics Co., Ltd. 
T375HF 
Phenolic, V-0, 
min. 0.85mm, 
150°C 
UL94 UL 
-Alt. use-  Sumitomo 
Bakelite Co., Ltd. 
PM-9820 
Phenolic, V-0, 
min. 0.85mm, 
150°C 
UL94 UL 
Insulation tape  Jingjiang Yahua 
Pressure 
Sensitive Glue 
Co., Ltd. 
CT 130°C 
UL510 
UL 
-Alt. use- 
Switching  
Transformer  
/ T541 
Shenzhen 
Haixinxing 
Electronics Co., 
Ltd. 
BCK-03EC35 
(36-TRF342-XX0-
A) 
Open, concentric 
winding  
IEC60065 
Tested in 
unit 
Bobbin material  Chang Chun 
Plastics Co., Ltd. 
T375HF 
Phenolic, V-0, 
min. 0.85mm, 
150°C 
UL94 UL 
Insulation tape  Jingjiang Yahua 
Pressure 
Sensitive Glue 
Co., Ltd. 
CT 130°C 
UL510 
UL 
-Alt. use-  Jingjiang Fuwei 
Adhesive 
Product Co., Ltd. 
FW 130°C 
UL510 
UL 
-Alt. use- 
Page of 95