Harman Kardon SB 26 (serv.man3) EMC - CB Certificate ▷ View online
Page 13 of 40
Report No.: ACSCBAV13004
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
12 Mechanical
strength
For SB26 CNTR: Not directly connected to the mains.
For SB26 SUB: See below
For SB26 SUB: See below
-
12.1.1
Bump test where mass >7 kg
Approx. 9.7 kg. (SB26 SUB)
Pass
12.1.2
Vibration test
Conducted on SB26 SUB.
Pass
12.1.3
Impact hammer test
Pass
Steel ball test
2J applied to enclosure, and
then no damaged.
then no damaged.
Pass
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg Not portable.
N/A
12.1.5
Thermoplastic enclosures stress relief test
N/A
12.2
Fixing of knobs, push buttons, keys and levers
N/A
12.3
Remote controls with hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
N/A
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
Clearances and creepage distances
For SB26 CNTR: Not directly connected to the mains.
For SB26 SUB: See below
For SB26 CNTR: Not directly connected to the mains.
For SB26 SUB: See below
-
13.1
Clearances in accordance with 13.3
See appended table 13.
Pass
Creepage distances in accordance with 13.4
See appended table 13.
Pass
13.2
Determination of working voltage
See appended table 13.
Pass
13.3
Clearances
See appended table 13.
Pass
13.3.1 General
Pass
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9.............:
with table 8 and, where applicable, table 9.............:
See appended table 13.
Pass
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
N/A
13.3.4 Measurement
of
transient voltages
N/A
13.4
Creepage distances
See appended table 13.
Pass
Creepage distances greater than table 11 minimum
values
values
See appended table 13.
Pass
13.5
Printed boards
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N/A
Page 14 of 40
Report No.: ACSCBAV13004
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Temperature cycle test and dielectric strength test
N/A
500V test for transformers, magnetic coupler and
similar devices, if insulation is relied upon for safety
similar devices, if insulation is relied upon for safety
N/A
13.7
Enclosed, enveloped or hermetically sealed parts
not conductively connected to the mains, clearances
and creepage distances as in table 12
not conductively connected to the mains, clearances
and creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N/A
14 Components
For SB26 CNTR: Not directly connected to the mains.
For SB26 SUB: See below
For SB26 SUB: See below
-
14.1 Resistors
N/A
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such resistors.
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
No such resistors.
N/A
Resistors
separately approved ...............................:
N/A
14.2
Capacitors and RC units
See appended table 14.
Pass
Capacitors separately approved :
Pass
14.2.1
Y capacitors tested to IEC 60384-14:2005 .............:
CY502, CY503, CY504,
CY505: Y1
CY505: Y1
Pass
14.2.2
X capacitors tested to IEC 60384-14:2005 .............:
CX501: X2
Pass
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 .......................:
connected to the mains: tests for X2 .......................:
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC 60384-1, 4.38 category B or better ..................:
short-circuit current exceeds 0,2 A: compliance with
IEC 60384-1, 4.38 category B or better ..................:
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................:
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................:
N/A
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal ........................................................................:
metal ........................................................................:
N/A
14.3
Inductors and windings
Pass
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
See CL. 20.1.4.
Pass
Page 15 of 40
Report No.: ACSCBAV13004
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
14.3.1
Transformers and inductors marked with
manufacturer's name and type ...............................:
manufacturer's name and type ...............................:
T541:
Type: BCK-AL140
Type: BCK-AL140
Mfg. Trademark:
-Alt. use-
Type: BCK-03EC35
Mfg. Trademark:
-Alt. use-
Type: BCK-PQ3230-L-5666
Mfg. Trademark:
Pass
Transformers and inductors separately approved .:
N/A
14.3.2
General
T541: Isolating transformer.
Pass
Insulation material complies with clause 20.1.4
See appended table 14.
Pass
14.3.3
Constructional requirements
See appended table 14.
Pass
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
See appended table 13.
Pass
14.3.3.2
Transformers meet the constructional requirements See appended table 13.
Pass
14.3.4
Separation between windings
Pass
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)..............................:
between hazardous live parts and accessible parts
(double or reinforced insulation)..............................:
See appended table 13.
Pass
Coil formers and partition walls > 0,4 mm
Pass
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic insulation
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
ACCESSIBLE parts
Pass
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
See appended table 13.
T541.
T541.
Pass
Coil formers and partition walls > 0,4 mm
Pass
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
N/A
Page 16 of 40
Report No.: ACSCBAV13004
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5
Protective devices
Pass
Protective devices used within their ratings
Primary fuse: F501
Pass
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
See appended table 13.
Pass
14.5.1.1
a) Thermal cut-outs separately approved
N/A
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
See appended table 14.
Pass
14.5.2.2
Correct marking of fuse-links adjacent to holder ...:
F501: T3.15AL250V
Pass
14.5.2.3
Not possible to connect fuses in parallel ................:
Pass
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool .........:
replacing fuse-links without the use of a tool .........:
Not replaced without a tool.
Pass
14.5.3
PTC thermistors comply with IEC 60730-1:2007
N/A
PTC devices (15 W) category V-1 or better
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
N/A
14.6
Switches
No switch.
N/A
14.6.1 a)
Separate testing to IEC 61058-1 including:
- 10 000 operations
- Normal pollution suitability
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
- 10 000 operations
- Normal pollution suitability
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
N/A
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1
N/A