Harman Kardon HS 500 (serv.man2) EMC - CB Certificate ▷ View online
Report No. JSH006030498-001
Page 44 of 82
9. Imm
ents a
eadphone output connector
(S2a)
9.1 Test result
Pass Fail
Not Applicable
9.2 Operating environment
Temperature: 20
Temperature: 20
°C Relative Humidity: 45 %
9.
set-up
The wanted test signal is supplied by generators G1,G2,G3 and G4, via the respective connections A or
V or S or T and the unwanted signal is supplied by generator G5. Network RCi matches the RF
disturbance source to the input impedance of the relevant audio terminal and a similar network Rco is
used to match the output terminals. Mains stop filter MSF is used to inject the unwanted signal at the
mains terminal and acts as a stop filter for unwanted signals from the mains network.
The equipment under test is placed 0.1m above the centre of a metal ground plane of dimensions 2m
by 1m. The mains lead shall be bundled to a length less than 0.3m and connected in the shortest
possible way to the mains stop filter MSF. The connection between the metal ground plane and the
shield of the RF cable at the audio input and output terminals shall be as short as possible.
The connecting cables are of the 50
Ω coaxial type.
The unwanted signal was amplitude modulated with 1kHz at 80% depth, supplied by generator G5.
9.3.1 Photo For test Set-up
none.
none.
9.4 Performance Criterion : A
9.5 Figure for test set up
unity requirem
t loudspeaker and h
3 Test
Report No. JSH006030498-001
Page 45 of 82
Report No. JSH006030498-001
Page 46 of 82
9.6 Test protocol
Inject Frequency(MHz)
Sound(dBuV)
Picture(dBuV)
Headphone
0.15 - 150.00
*
*
“*” means margin > 6 dB
10. Immunity requirements for audio input and output connectors (excluding loudspeaker and
headphone) (S2a)
10. Immunity requirements for audio input and output connectors (excluding loudspeaker and
headphone) (S2a)
10.1 Test result
Pass Fail Not Applicable
Pass Fail Not Applicable
10.2 Operating environment
Temperature: 20
Temperature: 20
°C
Relative Humidity: 45 %
10.3 Test set-up
The wanted test signal is supplied by generators G1,G2,G3 and G4, via the respective connections A or
V or S or T and the unwanted signal is supplied by generator G5. Network RCi matches the RF
disturbance source to the input impedance of the relevant audio terminal and a similar network Rco is
used to match the output terminals. Mains stop filter MSF is used to inject the unwanted signal at the
mains terminal and acts as a stop filter for unwanted signals from the mains network.
The equipment under test is placed 0.1m above the centre of a metal ground plane of dimensions 2m
by 1m. The mains lead shall be bundled to a length less than 0.3m and connected in the shortest
possible way to the mains stop filter MSF. The connection between the metal ground plane and the
shield of the RF cable at the audio input and output terminals shall be as short as possible.
The connecting cables are of the 50
The wanted test signal is supplied by generators G1,G2,G3 and G4, via the respective connections A or
V or S or T and the unwanted signal is supplied by generator G5. Network RCi matches the RF
disturbance source to the input impedance of the relevant audio terminal and a similar network Rco is
used to match the output terminals. Mains stop filter MSF is used to inject the unwanted signal at the
mains terminal and acts as a stop filter for unwanted signals from the mains network.
The equipment under test is placed 0.1m above the centre of a metal ground plane of dimensions 2m
by 1m. The mains lead shall be bundled to a length less than 0.3m and connected in the shortest
possible way to the mains stop filter MSF. The connection between the metal ground plane and the
shield of the RF cable at the audio input and output terminals shall be as short as possible.
The connecting cables are of the 50
Ω coaxial types.
The unwanted signal was amplitude modulated with 1kHz at 80% depth, supplied by generator G5.
10.3.1 Photo For test Set-up
none
10.3.1 Photo For test Set-up
none
10.4 Performance Criterion : A
10.5 Figure for test set up
Report No. JSH006030498-001
Page 47 of 82