Harman Kardon HS 500 (serv.man2) EMC - CB Certificate ▷ View online

 
 
Report No. JSH006030498-001 
Page 32 of 82  
6. Harmonics 
 
 
6.1 Block Diagram of Test Setup 
 
 
 
 
6.2 Test Setup and Test Procedure 
 
Harmonics of the fundamental current were measured up to 40 order harmonics using a digital 
power  
meter with an analogue output and frequency analyser which was integrated in the harmonic & 
flicker  
test system. The measurements were carried out under steady conditions . 
 
 
 
The appliance has rated input power less than 75W, and is not luminaire , and according to the  
 
standards, no limit apply. 
 
6.2.1  Photo For test Set-up
 
 
 
Test   result: 
PASS 
 
 
 
 
 
Harmonic & flicker 
test system 
     EUT 
 
 
Report No. JSH006030498-001 
Page 33 of 82  
6.3 Test Protocol 
20
°C  
Relative 
Humidity: 
45% 
Tes
Source qualification: Normal 
Curr nt & voltage waveforms
Temperature : 
 
 
t Result: Pass 
 
e
 
  
 
0.0
0.1
0.3
0
-100
0
100
200
300
  
u
rr
Voltage (Volts)
 
0.2
s)
p
A
m
(
-0.1
e
n
-0.2
-20
C
-0.3
-300
 
armonics and Class A limit line
H
 European 
Limits 
 
0.0
0.5
1.0
1.5
2.0
2.5
3.0
  
Current RMS(Amps)
Harmonic #
4
8
12
16
20
24
28
32
36
40
 
 
3.5
Test result:  Pass     Worst harmonic was #31 with 1.80% of the limit.  
                 
  
                 
  
 
 
Report No. JSH006030498-001 
Page 34 of 82  
Current Test Result Summary (Run time) 
est Result: Pass 
Source qualification:  Normal 
HD(pk%): 18.08      
imit(A):  0.251          
ighest parameter values during test: 
 
Freque
y(Hz):   50.00 
I_RMS (Amps):  0.173 
I_Fund (Amps):  0.170 
Crest Factor: 
1.765 
Power (Watts):   28.5 
Power Factor: 
0.715 
 
Harm# Harms(avg) 100%Limit %of Limit  Harms(max) 150%Limit %of 
Limit Status 
 
 
2  0.001 1.080  0.1 
0.001 1.620 0.07 
Pass 
 
3  0.027 2.300  1.2 
0.029 3.450 0.84 
Pass 
 
4  0.001 0.430  0.1 
0.001 0.645 0.12 
Pass 
 
5  0.005 1.140  0.4 
0.006 1.710 0.32 
Pass 
 
6  0.000 0.300  0.1 
0.001 0.450 0.13 
Pass 
 
7  0.003 0.770  0.4 
0.004 1.155 0.33 
Pass 
 
8  0.000 0.230  0.1 
0.000 0.345 0.08 
Pass 
 
9  0.004 0.400  0.9 
0.004 0.600 0.67 
Pass 
 
10  0.000 0.184  0.1 
0.000 0.276 0.06 
Pass 
 
11  0.004 0.330  1.4 
0.005 0.495 0.96 
Pass 
 
12  0.000 0.153  0.1 
0.000 0.230 0.09 
Pass 
 
13  0.001 0.210  0.6 
0.001 0.315 0.43 
Pass 
 
14  0.000 0.131  0.1 
0.000 0.197 0.11 
Pass 
 
15  0.002 0.150  1.1 
0.002 0.225 0.86 
Pass 
 
16  0.000 0.115  0.2 
0.000 0.173 0.18 
Pass 
 
17  0.001 0.132  0.9 
0.002 0.199 0.80 
Pass 
18  0.000 0.102  0.1 
0.000 0.153 0.13 
Pass 
02 0.178 1.00 
Pass 
20  0.000 0.092  0.2 
0.000 0.138 0.30 
Pass 
 
21  0.002 0.107  1.6 
0.002 0.161 1.36 
Pass 
 
22  0.000 0.084  0.2 
0.000 0.125 0.24 
Pass 
 
23  0.002 0.098  1.8 
0.002 0.147 1.50 
Pass 
 
24  0.000 0.077  0.2 
0.000 0.115 0.20 
Pass 
 
25  0.000 0.090  0.4 
0.001 0.135 0.45 
Pass 
 
26  0.000 0.071  0.2 
0.000 0.106 0.22 
Pass 
 
27  0.001 0.083  1.1 
0.001 0.125 0.90 
Pass 
 
28  0.000 0.066  0.2 
0.000 0.099 0.20 
Pass 
 
29  0.001 0.078  1.5 
0.002 0.116 1.31 
Pass 
 
30  0.000 0.061  0.1 
0.000 0.092 0.15 
Pass 
 
31  0.002 0.073  2.1 
0.002 0.109 1.80 
Pass 
 
32  0.000 0.058  0.1 
0.000 0.086 0.15 
Pass 
 
33  0.001 0.068  0.9 
0.001 0.102 0.85 
Pass 
 
34  0.000 0.054  0.2 
0.000 0.081 0.25 
Pass 
 
35  0.001 0.064  1.1 
0.001 0.096 1.03 
Pass 
 
36  0.000 0.051  0.2 
0.000 0.077 0.22 
Pass 
 
37  0.001 0.061  0.9 
0.001 0.091 0.80 
Pass 
 
38  0.000 0.048  0.1 
0.000 0.073 0.15 
Pass 
 
39  0.001 0.058  1.4 
0.001 0.087 1.08 
Pass 
 
40  0.000 0.046  0.7 
0.000 0.069 0.60 
Pass 
surement uncertainty for harmonic test is nder consideration according to CISPR 16- 
4:2002 
 
6.5 Additions, Deviations and Exclusions from Standards  
 
 None 
 
 
T
THC(A): 0.03       I-T
   POHC(A):  0.004        POHC L
H
V_RMS (Volts):   229.80
nc
I_Peak (Amps):  0.295 
 
 
19  0.001 0.118  1.2 
0.0
 
 
6.4 Measurement Uncertainty  
 
The mea
 u
 
 
Report No. JSH006030498-001 
Page 35 of 82  
7. Voltage Fluctuations-Flicker 
7.1 Blo
tup 
 
 
io
er
ld
ri
g
 
Test result 
PASS 
 
ck Diagram of Test Se
   
Harmonic & flicker 
test system 
     EUT 
 
 
7.2 Test Setup and Test Procedure 
7.2.1 Definition
 
Flicker:  
impression of unsteadiness of visual sensat n induced by a lighting stimulus whose  
 
 
 
luminance or spectral distribution fluctuates with time. 
 
 
Pst:   
Short-term flicker indicator The flicker sev ity evaluated over a short period (in  
 
 
 
minutes); Pst=1 is the conventional  thresho  of irritability  
 
Plt:   
long-term flicker indicator; the flicker seve ty evaluated over a long period (a few 
hous) 
 
 
 
Using successive Pst valuse. 
 
dc:   
the relative steady-state volta e change 
 
dmax: 
the maximum relative voltage change 
 
d(t):  
the value during a voltage change  
7.2.2  Photo For test Set-up 
 
none
Page of 83