Harman Kardon HS 500 (serv.man2) EMC - CB Certificate ▷ View online
Report No. JSH006030498-001
Page 56 of 82
Note: HCP means H
14.2 Block Diagram of Test Setup
Best EMC
EU
ESD simulator
VCP
HCP
Insulate
Support
Support
470k
Ω
Resist
o
T
GRP
orizontal Coupling Plane,
VCP means Vertical Coupling Plane
GRP means Ground Reference Plane
GRP means Ground Reference Plane
14.3 Test Setup and Test Procedure
14.3.1 Test setup
Tabletop EUT
The EUT was put on a 0.8m high wooden tabel, standing on the ground reference
plane(GRP) 2.6m by 1.8m in size, made by aluminium 0.5mm thick.
A horizontal coupling plane(HCP) 1.6m by 0.8m in size was placed on the table, and
the EUT with its cables were isolated from the HCP by an insulating support thick
than 0.5mm. The VCP 0.5m by 0.5m in size & HCP were constructed from the same
material type & thinkmess as that of the GRP, and connected to the GRP via a 470k
plane(GRP) 2.6m by 1.8m in size, made by aluminium 0.5mm thick.
A horizontal coupling plane(HCP) 1.6m by 0.8m in size was placed on the table, and
the EUT with its cables were isolated from the HCP by an insulating support thick
than 0.5mm. The VCP 0.5m by 0.5m in size & HCP were constructed from the same
material type & thinkmess as that of the GRP, and connected to the GRP via a 470k
Ω
resistor at each end.
The distance between EUT and any of the other metallic surface excepted the GRP, HCP
& VCP was greater than 1m.
The EUT was arranged and connected according to its functional requirements.
The distance between EUT and any of the other metallic surface excepted the GRP, HCP
& VCP was greater than 1m.
The EUT was arranged and connected according to its functional requirements.
Report No. JSH006030498-001
Page 57 of 82
Floor standing EUT
The EUT was put on a 0.1m high wooder support, standing on the ground reference
plane(GRP) 2.6m by 1.8m, made by aluminuim 0.5mm thick.
A vertical coupling plane (VCP) 0.5m by 0.5m in size, the same material type and
A vertical coupling plane (VCP) 0.5m by 0.5m in size, the same material type and
ss as that
of the ground reference plane was applied ,and was connected to the GRP via a 470k
Ω resistor at
each end.
The distance between EUT and any of the other metallic surface excepted the GRP, HCP & VCP
was greater than 1m.
The distance between EUT and any of the other metallic surface excepted the GRP, HCP & VCP
was greater than 1m.
The EUT was arranged and connected according to its functional requirements.
14.3.2 Test Procedure
The EUT was
d and connected according to its functional requirements
Direct static electricity discharges was applied only to those points and surface which are
accessible to
personnel during normal usage.
The test voltage was increased from the minimum to the selected test level and with single
The test voltage was increased from the minimum to the selected test level and with single
discharge.
On each preselected points 10 times of each polarity single discharge were applied
The time interval between successive single discharges is 1s.
The ESD generator was held perpendicula
The time interval between successive single discharges is 1s.
The ESD generator was held perpendicula
surface to which the discharge is applied. The
discharge return cable of the generator was kept at a distance of 0.2m whilst the discharge is being
applied. During the contact discharges, the tip of the discharge electrode was touch the EUT before
applied. During the contact discharges, the tip of the discharge electrode was touch the EUT before
air discharges, the round discharge tip of the discharge
el
ble to touch the EUT.
A
removed from the EUT, the generator is then
triggered
for a new single discharge.
o objects placed near the EUT, simulated by applying the
disch
the ESD generator to a coupling plane, in the contact discharge mode.
h polarity single discharge were applied to HCP and VCP. The detail selected
listed in the following table.
14.3.
hoto For Test Set-up
14.4
ontact
(+/-)
Fail
thickne
arrange
r to the
the discharge switch is operated. During the
ectrode was approached as fast as possi
fter each discharge, the ESD generator was
fter each discharge, the ESD generator was
re
Indirect discharge was conducted t
ares
of
10 times of eac
10 times of eac
points are
3 P
none
Test Protocol
Test Protocol
Temperature :
23
°C
Relative Humidity:
34%
Direct discharge was applied at the following selected points:
Air/
Polarity
Pass/
Comment
Test point
#
Test level
[kV]
C
A
4
Contact
+/-
P
All touchable screws of
enclosure
enclosure
B
4
Contact
+/-
P
Accessible metal parts of the
EUT
EUT
C
8
Air
+/-
P
Air gap of the switch, button
D
8
Air
+/-
P
The air in-taking opening
E
8
Air
+/-
P
Slots around the EUT
Report No. JSH006030498-001
Page 58 of 82
Indirect contact discharges were applied to the VCP and the HCP at the following selected points:
Description
Point
Result
Point
HCP f
0,1m from the front of the EUT
Edge of centre,coner on HCP
P
HCP b
0,1m from the back of the EUT
Edge of centre,coner on HCP
P
HCP r
0,1m from the right side of the EUT
Edge of centre,coner on HCP
P
HCP l
0,1m from the left side of the EUT
Edge of centre,coner on HCP
P
VCP f
0,1m from the front of the EUT
Edge of centre,coner on VCP
P
VCP b
0,1m from the back of the EUT
Edge of centre,coner on VCP
P
VCP r
0,1m from the right of the EUT
Edge of centre,coner on VCP
P
VCP l
0,1m from the left of the EUT
Edge of centre,coner on VCP
P
14.5
Additions, Deviations and Exclusions from Standards
None
Report No. JSH006030498-001
Page 59 of 82
15. E
c
mmunit
T
u
15.1 S
y
erion
15.1.1 Test level
n
d repeti
lectri Fast Transient/Burst I
y Test
est res lt
PASS
everit Level and Performance Crit
Ope circuit output test voltage(+/-10%) an
tion rate of the impulses (+/- 20%)
On power supply port PE
t) signal,
data and control ports
On I/O (input & outpu
Level
kV
kHz
Voltage peak
kV
Repetition rate
kHz
Voltage peak
Repetition rate
1 0.5 5 0.25 5
2
1
5
0.5 5
3 2 5 1 5
4 4
2.5
2 5
X
Special
Special
Special
Special
Notes : 1. “X” is a an open level. The level has to be specified in the dedicated equipment specification.
2. The gray rows were the selected test level.
15.1.2 Performance Criterion
Performance
criterion
B