Harman Kardon HS 350 (serv.man2) EMC - CB Certificate ▷ View online
Page 27 of 67 Report No. JSH007120244-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
5.1
TABLE: rated current/power consumption
Pass
Model
Input voltage
(V)
(V)
Rated
current
(mA)
current
(mA)
Measured
current
(mA)
current
(mA)
Rated
power (W)
power (W)
Measured
power (W)
power (W)
condition/status
240 -
230 230 43.7
HS 350
100 -
450 230 43.8
Normal DVD playing
7.1
TABLE: temperature rise measurements
Pass
Power consumption in the OFF/Stand-by
0W/2.1W max.
—
Position of the functional switch (W) ...................... :
On
—
Room temperature t1 (°C) ...................................:
21.5
Room temperature t2 (°C) ...................................:
21.5
Operating conditions
Normal DVD playing, with 1/8 non-clipped 400Hz sinusoidal output power to the speaker, operates 4 hours
until steady condition reached.
until steady condition reached.
Un (V)
In (mA)
Pn (W)
Pout (V / mA)
264 220
43.7
N.A.
90 500
44.9
N.A.
Loudspeaker impedance (Ω) ................................. : 6 Ω X 5
—
Several loudspeaker systems
5 channel speakers
Pass
Marking of loudspeaker terminals
Printed on rear enclosure
Pass
dT (K)
monitored point:
264
90
Permitted dT (K)
Connector(CN701) 16.8
20.8
-
CX703 (X2 capacitor )
20.1
25.7
50 (85-35)
Winding of LF705
21.0
25.1
65*
CX702 (X2 capacitor )
24.0
26.3
50 (85-35)
Winding of LF704
20.4
22.9
65*
PCB near BD701
27.1
30.7
75
PCB near Q703
26.9
29.5
75
Winding of LF703
26.4
32.7
65*
Page 28 of 67 Report No. JSH007120244-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Operating conditions
CE702(electrolytic capacitor)
28.6
31.0
70 (105-35)
CY701(Y1 capacitor)
33.7
36.0
50 (85-35)
Winding of T702
42.8
44.2
65*
Bobbin of T702
39.9
41.1
65
PCB near T702
38.9
40.1
75
Winding of T701
31.9
32.9
65*
Bobbin of T701
21.7
22.5
65
PCB near T701
22.5
23.3
75
PCB near D710
32.3
33.3
75
Power cord
12.0
14.0
50
PCB near U4
41.5
41.6
75
PCB near U201
43.0
43.1
75
PCB near U204
50.0
50.0
75
PCB near U422
45.2
45.1
75
PCB near U412
41.8
41.7
75
PCB near U421
50.0
50.2
75
PCB near U404
52.4
52.4
75
PCB near U406
50.3
50.4
75
PCB near U407
42.6
42.5
75
PCB near U410
43.8
43.7
75
PCB near U413
43.0
42.9
75
Enclosure (metallic)
17.1
17.0
30
Enclosure (non-metallic)
14.8
14.6
50
winding temperature rise measurements:
Temperature rise dT of winding:
R1 (Ω) R2 (Ω)
dT (K)
required
dT (K)
dT (K)
Insulation
class
class
Page 29 of 67 Report No. JSH007120244-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
10.3
TABLE: insulation resistance measurements
Pass
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
100
2
Between parts separated by basic or supplementary insulation
100
2
Between parts separated by double or reinforced insulation
20.6
4
Between parts of T701 separated by basic or supplementary
insulation
insulation
100 2
Between parts of T702 separated by basic or supplementary
insulation
insulation
100 2
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120Vp
No
Between parts separated by basic or supplementary insulation
2120Vp
No
Between parts separated by double or reinforced insulation
4240Vp
No
Between parts of T701 separated by basic or supplementary
insulation
insulation
2454Vp No
Between parts of T702 separated by basic or supplementary
insulation
insulation
2520Vp No
11.2
TABLE: summary of fault condition tests
Pass
Model/type of power supply .................................: --
—
Voltage (V) 0,9 or 1,1 times rated voltage ............. : 100-240
Ambient temperature (
o
C) ...................................... : 24
—
No.
Component
No.
Fault
Test
voltage
(V)
Test
time
Fuse
No.
Fuse
current
(A)
Result
Dielectric
strength
test after
the test
1.
U711:
secondary
SC 264 5
min.
F702
0.069
P=1.3W. No high
temperature, no hazard.
temperature, no hazard.
Pass
2.
D725 SC
264
5 min.
F702
0.069
P=1.3W. No high
temperature, no hazard.
temperature, no hazard.
Pass
3.
CE727 SC
264
15 min.
F702
0.18→
0.07
P=13.5W max. No high
temperature, no hazard.
temperature, no hazard.
Pass
4.
D722
SC
264
15 min.
F702
0.113
P=10.5W. No high
temperature, no hazard.
temperature, no hazard.
Pass
Page 30 of 67 Report No. JSH007120244-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
5.
CE718 SC
264
15 min.
F702
0.17→
0.09
P=12.5W max. No high
temperature, no hazard.
temperature, no hazard.
Pass
6.
D709
SC
264
5 min.
F702
0.069
P=1.3W. No high
temperature, no hazard.
temperature, no hazard.
Pass
7.
CE715 SC
264
15 min.
F702
0.10
P=8.6W max. No high
temperature, no hazard.
temperature, no hazard.
Pass
8.
D735 SC
264
20 min.
F702
0.83→
0.52→
0.52→
0.09
P=165W max, P=70W min.
1.5 minutes, P=6.0W max.
No high temperature, no
hazard.
1.5 minutes, P=6.0W max.
No high temperature, no
hazard.
Pass
9.
CE725 SC
264
15 min.
F702
0.15
P=14.0W max. No high
temperature, no hazard.
temperature, no hazard.
Pass
10.
U707:
secondary
SC 264
20
min.
F702
0.16
P=17.9W. No high
temperature, no hazard.
temperature, no hazard.
Pass
11.
U707:
primary
SC 264
50
min.
F702
0.22
P=44W, as normal. No high
temperature, no hazard.
temperature, no hazard.
Pass
12.
U711:
primary
SC 264 5
min.
F702
0.069
P=1.5W. No high
temperature, no hazard.
temperature, no hazard.
Pass
13.
D720 SC
264
20 min.
F702
0.16
P=17.9W. No high
temperature, no hazard.
temperature, no hazard.
Pass
14.
D724
SC
264
5 min.
F702
0.069
P=1.5W. No high
temperature, no hazard.
temperature, no hazard.
Pass
15.
R816
SC
264
50 min.
F702
0.22
P=44W, as normal. No high
temperature, no hazard.
temperature, no hazard.
Pass
16.
CE722
SC
264
5 min.
F702
0.069
P=1.5W. No high
temperature, no hazard.
temperature, no hazard.
Pass
17.
CE713 SC
264
20 min.
F702
0.16
P=17.8W. No high
temperature, no hazard.
temperature, no hazard.
Pass
18.
D721
SC
264
2 H
F702
0.30
P=66W max. No extremely
high temperature, no hazard.
high temperature, no hazard.
Pass
19.
U704:
secondary
SC 264
50
min.
F702
0.18
P=31W max. No extremely
high temperature, no hazard.
high temperature, no hazard.
Pass
20.
D710
SC
264
1H
F702
0.33→
0.64→
0.64→
0.14
P=66W max, 5 minutes,
P=110W max, 12 minutes,
P=18.8W max. No extremely
high temperature, no hazard.
P=110W max, 12 minutes,
P=18.8W max. No extremely
high temperature, no hazard.
Pass
21.
CE710
SC
264
30 min.
F702
0.19→
0.16
P=25W max. No extremely
high temperature, no hazard.
high temperature, no hazard.
Pass
22.
D703
SC
264
1H
F702
0.33→
0.64→
0.64→
0.14
P=66W max, 5 minutes,
P=110W max, 12 minutes,
P=18.8W max. No extremely
high temperature, no hazard.
P=110W max, 12 minutes,
P=18.8W max. No extremely
high temperature, no hazard.
Pass
23.
CE706
SC
264
30 min.
F702
0.19→
0.16
P=25W max. No extremely
high temperature, no hazard.
high temperature, no hazard.
Pass
24.
U704:
primary
SC 264
20
min.
F702
0.14
P=18.9W max. No extremely
high temperature, no hazard.
high temperature, no hazard.
Pass
25.
R760
SC
264
20 min.
F702
0.16
P=17.9W max. No extremely
high temperature, no hazard.
high temperature, no hazard.
Pass