Harman Kardon HS 350 (serv.man2) EMC - CB Certificate ▷ View online
Page 39 of 67 Report No. JSH007120244-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
Laser pickup unit Hitachi Media
Electronics Co.,
Ltd
HOP-1200W
CD mode:
60.0μW,
DVD mode:
76.0μW
Class 1
IEC60825-1 Tested
with
appliance
Laser diode for
CD
SHARP
CORPORATION
GH17805B2AS 790nm
Class 1
IEC60825-1 Tested
with
appliance
Laser diode for
DVD
ROHM CO., LTD RLD65MPT5
655nm
Class 1
IEC60825-1 Tested
with
appliance
PCB
SUN HUNG
(ZHUHAI)
ELECTRONICS
TECHNOLOGY
CO LTD
SHDS01 FV-0
IEC60695-11-10
UL94
UL94
UL(E228944)
PCB,
alternative
various various
FV-0 IEC60695-11-10
UL94
UL
Insulation Sheet
(under the power
board)
BERGQUIST CO Sil-Pad 400
Thickness:
0.41mm min.
FV0, 150℃
IEC 60065
UL: E59150
and tested
with appliance
and tested
with appliance
Connector
MOLEX INC
35977
35979
--
IEC 60065
UL: E29179
and tested
with appliance
and tested
with appliance
Flexible cord
SHENZHEN
ZHENGERYA
CABLE CO LTD
NISPTT-2
300V 105
°C
VM-1, 18AWG
double
insulation
IEC 60065
UL: E242647
and tested
with appliance
and tested
with appliance
NTC, RZ701,
RZ702
-- --
8Ω, 25
°C
IEC 60065
Tested with
appliance
appliance
Page 40 of 67 Report No. JSH007120244-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
Discharging
resistor R809
-- --
1MΩ/0.5W
IEC 60065
Tested with
appliance
appliance
Cord set:
According to the manufacturers declaration, the unit will be supplied with a power attachment cord, plug
and connector which meet the national requirements which have been approved to relevant national
and international standards.
According to the manufacturers declaration, the unit will be supplied with a power attachment cord, plug
and connector which meet the national requirements which have been approved to relevant national
and international standards.
Page 41 of 67 Report No. JSH007120244-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
National differences for CHINA
(According to CB bulletin No. 112A. These differences are taken from
IEC60065:1998 and adopted to IEC 60065:2001.)
(According to CB bulletin No. 112A. These differences are taken from
IEC60065:1998 and adopted to IEC 60065:2001.)
4.2.1 first sentence replaced by:
The apparatus is connected to a supply voltage
of 0.9 times or 1.1 times of any RATED SUPPLY
VOLTAGE for which the apparatus is designed.
The apparatus is connected to a supply voltage
of 0.9 times or 1.1 times of any RATED SUPPLY
VOLTAGE for which the apparatus is designed.
Pass
5.1f) Second paragraph replaced by:
………When single rated voltage is given, it
should be marked 220 V, For a rating range, it
should cover 220 V; when multiple RATED
VOLTAGES are given, one of them must be
220V and also factory default setting should be
220 V.
………When single rated voltage is given, it
should be marked 220 V, For a rating range, it
should cover 220 V; when multiple RATED
VOLTAGES are given, one of them must be
220V and also factory default setting should be
220 V.
Pass
5.4 replaced by:
When information with regard to safety is
required according to this standard, this
information shall be given in an instruction for
installation or use and supplied with the
apparatus. This information shall be given in
simplify Chinese where the apparatus is intended
to be used.
When information with regard to safety is
required according to this standard, this
information shall be given in an instruction for
installation or use and supplied with the
apparatus. This information shall be given in
simplify Chinese where the apparatus is intended
to be used.
Pass
15.1.1 first sentence replaced by:
Plugs and appliance couplers for the connection
of the apparatus to the MAINS and socket-outlets
and interconnection couplers for providing MAINS
power to other apparatus shall comply with the
Chinese National standards, Industrial standards
or relevant IEC standards for plugs and socket-
outlets, appliance couplers or interconnection
couplers.
Plugs and appliance couplers for the connection
of the apparatus to the MAINS and socket-outlets
and interconnection couplers for providing MAINS
power to other apparatus shall comply with the
Chinese National standards, Industrial standards
or relevant IEC standards for plugs and socket-
outlets, appliance couplers or interconnection
couplers.
Pass
National differences for KOREA
(According to CB bulletin No. 112A. These differences are taken from
IEC60065:1998 and adopted to IEC 60065:2001.)
(According to CB bulletin No. 112A. These differences are taken from
IEC60065:1998 and adopted to IEC 60065:2001.)
5.101
Other marking ; Wording "____ “ or an
information regulated in IEC Publication 417
giving high voltage warning to layman shall
be marked, if an apparatus contains a part more
than 600volts.
information regulated in IEC Publication 417
giving high voltage warning to layman shall
be marked, if an apparatus contains a part more
than 600volts.
N/A
15.1.1
Plugs for the connection of the apparatus to the
supply mains and socket outlets for providing
mains power to other apparatus shall
comply with the Korean requirements (KSC8300
and 8305).
supply mains and socket outlets for providing
mains power to other apparatus shall
comply with the Korean requirements (KSC8300
and 8305).
Pass
31
Radio frequency interference
The apparatus shall comply with the relevant
CISPR requirements.(EMC = EMI + EMS)
The apparatus shall comply with the relevant
CISPR requirements.(EMC = EMI + EMS)
Pass
Page 42 of 67 Report No. JSH007120244-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
National differences for SINGAPORE
(According to CB bulletin No. 112A. These differences are taken from
IEC60065:1992 and adopted to IEC 60065:2001.)
(According to CB bulletin No. 112A. These differences are taken from
IEC60065:1992 and adopted to IEC 60065:2001.)
Throughout the standard
, whenever the words “white pine board” appear, insert
the words “or plywood board” to it.
Pass
SS 143 Amendment No.1 and No. 2
4.1.3
Delete “45 % to 75 %” and insert “65 _ 5 %”.
75% maximum in IEC
60065:2001
60065:2001
Pass
7.1
Resistance to heat without external forces
Adopt the temperature specified for the tropical
conditions.
Adopt the temperature specified for the tropical
conditions.
Pass
9.3.4
Delete the note “A Quality Assessment System
for capacitors complying with Subclause 14.2 is
under consideration in the IEC”.
for capacitors complying with Subclause 14.2 is
under consideration in the IEC”.
This is not in IEC 60065:2001.
Pass
10.2
Humidity treatment
Adopt the testing conditions designed for tropical
conditions.
Adopt the testing conditions designed for tropical
conditions.
120h at a relative humidity of
93%, ambient temperature
40
93%, ambient temperature
40
o
C
Pass
16
External flexible cords
Delete “IEC Publication 227: Polyvinyl Cloride
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC Publication 245:
Rubber Insulated Cables of Rated Voltage up to
and including 450/750V” and insert “Singapore
Standard 236: Flexible Cords”, whenever they
appear in this clause.
Delete “CEE Publication 13, CEE Publication 2
and IEC Publication 173: Colours of the Cores of
Flexible Cables and Cords” whenever they
appear in this clause.
Delete “IEC Publication 227: Polyvinyl Cloride
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC Publication 245:
Rubber Insulated Cables of Rated Voltage up to
and including 450/750V” and insert “Singapore
Standard 236: Flexible Cords”, whenever they
appear in this clause.
Delete “CEE Publication 13, CEE Publication 2
and IEC Publication 173: Colours of the Cores of
Flexible Cables and Cords” whenever they
appear in this clause.
Pass
16.2
Delete the notes in small print and insert “A
nominal cross-sectional area of 0.75 mm
nominal cross-sectional area of 0.75 mm
2
will
satisfy this requirement”.
Pass
16.4b
Delete “Subclause 3.1 of IEC Publication 227-2:
Part 2: Test Methods” and insert “Subclause 9.1
of SS 236”:
9.1 Flexing Test (except for tinsel cords, twisted
twin and single core cords).
The test shall be carried out by mieans of the
apparatus shown in Figure 5. This apparatus has
a carrier C supporting two pulleys A and B
arranged so that the cord is horizontal between
the pulleys. The carrier moves backward and
forward over a distance of 1 m at an
approximately constant speed of 0.33 m/s.
A sample of flexible cord fabout 5 m long shall be
stretched over the pulleys as shown in the figure,
each end being loaded with a weight. The weight
and the diameter of the pulleys A and B shall be
Part 2: Test Methods” and insert “Subclause 9.1
of SS 236”:
9.1 Flexing Test (except for tinsel cords, twisted
twin and single core cords).
The test shall be carried out by mieans of the
apparatus shown in Figure 5. This apparatus has
a carrier C supporting two pulleys A and B
arranged so that the cord is horizontal between
the pulleys. The carrier moves backward and
forward over a distance of 1 m at an
approximately constant speed of 0.33 m/s.
A sample of flexible cord fabout 5 m long shall be
stretched over the pulleys as shown in the figure,
each end being loaded with a weight. The weight
and the diameter of the pulleys A and B shall be
Pass
Click on the first or last page to see other HS 350 (serv.man2) service manuals if exist.