                                                                   Page 11 of 67                        Report No. JSH007120244-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12
         
 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
         
 
N/A 
 
14 COMPONENTS 
 
14.1 Resistors 
 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
R701, R702 
Pass 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N/A 
 
Resistors separately approved  .............................. : R701, R702 approved by VDE
 
Pass 
14.2 
Capacitors and RC units 
 
Pass 
 
Capacitors separately approved 
Yes  
Pass 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition  .. : Y1: CY701, CY702, CY703, 
CY705 
Pass 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition  .. : X2: CX701, CX702, CX703 
Pass 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ..................... :
No such component 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better ....................................................................... :
Such capacitors with metal 
cased 
N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better ........................................ :
Such capacitors with metal 
cased 
N/A 
 
Shielded by a barrier to V-0 or metal  ..................... :  N/A 
14.3 
Inductors and windings 
 
Pass 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 N/A 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type .............................. :
Power transformer T701, T702 
Line filter LF704, LF705  
(See appended table14) 
Pass 
 
Transformers and inductors separately approved . : No 
N/A 
14.3.2 General 
 
Pass 
14.3.3 Constructional 
requirements 
 
Pass 
 
                                                                   Page 12 of 67                        Report No. JSH007120244-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
(see appended table) 
Pass 
14.3.3.2 
Transformers meet the constructional 
requirements 
 Pass 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
T701 basic insulation 
minimum 4.0 mm between 
T701 core and primary, 
Supplementary insulation 
minimum 4.0mm between 
T701 core and secondary. 
T702 basic insulation 
minimum 4.0 mm between 
T702 core and primary, 
Supplementary insulation 
minimum 4.0mm between 
T702 core and secondary. 
Pass 
 
Coil formers and partition walls > 0,4 mm 
T701 bobbin: 0.75mm min. 
T702 bobbin: 0.75mm min. 
Pass 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
Class II construction 
N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 
N/A 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
T701 basic insulation 
minimum 4.0 mm between 
T701 core and primary, 
Supplementary insulation 
minimum 4.0mm between 
T701 core and secondary. 
T702 basic insulation 
minimum 4.0 mm between 
T702 core and primary, 
Supplementary insulation 
minimum 4.0mm between 
T702 core and secondary.
 
Pass 
 
Coil formers and partition walls > 0,4 mm 
T701 bobbin: 0.75mm min. 
T702 bobbin: 0.75mm min.
 
Pass 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
Class II construction 
N/A 
 
                                                                   Page 13 of 67                        Report No. JSH007120244-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N/A 
14.4 
High voltage components 
No such components 
N/A 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 
N/A 
 
Component meets category V-1 of IEC 60707 
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 
N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 
N/A 
14.5 Protective 
devices 
 
Pass 
 
Protective devices used within their ratings 
 
Pass 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
Fuse,  F702: 8.5mm  
F701: 5.0mm 
Pass 
14.5.1.1 
a) Thermal cut-outs separately approved 
No such components 
N/A 
 
b) Thermal cut-outs tested as part of the 
submission 
 
N/A 
14.5.1.2 
a) Thermal links separately approved 
No such components 
N/A 
 
b) Thermal links tested as part of the submission 
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
F702, F701 approved. 
Pass 
14.5.2.2 
Correct marking of fuse-links adjacent to holder ... : F702: T5A L 250V  
F701: T3.15A L 250V 
Pass 
14.5.2.3 
Not possible to connect fuses in parallel ............... : Separate fuse holder used 
Pass 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool ......... :
 
 
Pass 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
No such parts 
N/A 
 
PTC-S devices (15 W) category V-1 or better 
 
N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked 
 
N/A 
14.6 Switches 
No 
switch 
N/A 
 
                                                                   Page 14 of 67                        Report No. JSH007120244-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
14.6.1 a) 
Separate testing to IEC 61058 including: 
10 000 operations 
Normal pollution suitability 
Resistance to heat and fire level 3 
and 
V-0 compliance with annex G, G.1.1 
         
 N/A 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with 
14.6.3, 14.6.4 and V-0 in annex G, G.1.1 
 N/A 
 
Switch controlling > 0.2A with open contact  
voltage < 35 V (peak)/24 V dc complying with 
14.6.3 and V-0 in annex G, G.1.1 
 N/A 
 
Switch controlling < 0.2A with open contact  
voltage > 35 V (peak)/24 V dc complying with  
14.6.4 and V-0 in annex G, G.1.1 
         
 N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 
61058-1 subclause 13.1 and has making/breaking  
action independent of speed of actuation 
         
 N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 
61058-1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use 
         
 N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength 
         
 N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 60058-1 
         
 N/A 
 
Socket outlet current marking correct 
         
 N/A 
14.7 
Safety interlocks 
No such parts 
N/A 
 
Safety interlocks to 2.8 of IEC 60950 
         
 N/A 
14.8 
Voltage setting devices 
No such parts 
N/A 
 
Voltage setting device not likely to be changed 
accidentally 
         
 N/A 
14.9 Motors 
 
N/A 
14.9.1 
Endurance test on motors 
Only low voltage DC servo 
motor in DVD loader 
N/A 
 
Motor start test 
         
 N/A 
 
Dielectric strength test 
         
 N/A 
Page of 69