Harman Kardon HS 300 (serv.man3) EMC - CB Certificate ▷ View online
Report No. JSH006030124-001
Page 68 of 81
18.2 Diagram of Test Setup
CDN
AC
power
power
EUT
RF Generator
with amplifier
with amplifier
4dB
GRP 10cm high
wooden plane
to support The
to support The
3 cm high
wooden plane
to support EUT
wooden plane
to support EUT
power lead :
signal cable :
18.3 Test Setup and Test Procedure
The EUT was placed on an insulating support of 0.1m height above a ground reference Plane,
arranged and connected to satisfy its functional requirement.
arranged and connected to satisfy its functional requirement.
All relevant cables were provided with the appropriate coupling and decoupling
devices at a distance between 0.1m and 0.3m from the projected geometry of the EUT on an
insulating support of 0.03m height above the ground reference plane.
The frequency from 0.15MHz to 230MHz was checked.
18.3.1 Photo for test set-up
none
18.4 Test Protocol
Temperature :
23
°C
Relative Humidity:
34%
Test No.
Frequency
(MHz)
Level
V (e.m.f.)
Amplitude
modulation
Injected
point
Result Comment
1 0.15~80 3 1kHz
80%
L-N Pass
2 0.15~80 3 1kHz
80%
L-N-PE NA
18.5 Additions, Deviations and Exclusions from Standards
None
Report No. JSH006030124-001
Page 69 of 81
19. Voltage Dips, Short Interruptions and Voltage Variations
Immunity Test
Immunity Test
Test result
PASS
19.1 Severity Level and Performance Criterion
19.1.1 Test level
Test level
% UT
Voltage dip and short interruptions
% UT
Duration
(in period)
0
100
40
60
70
30
0.5 *
1
5
5
10
25
50
25
50
X **
Notes:
1.“*” for 0.5 period, the test shall be made in positive and negative polarity, i.e.
starting at 0
° and 180°, respectively
2. “**” means “x” is an open duration. This duration can be given in the product
specification.. Utilities in Europe have measured dips and short interruptions of
duration between ½ a period and 3000 periods, but duration less than 50 periods
are most common.
3. if the EUT is tested for voltage dips of 100%, it is generally unnecessary to test for
other levels for the same durations. However, for some cases(safeguard systems or
electro-mechanical devices) it is not true. The product specification or product
committee shall give an indication of the applicability of this note.
4. The gray rows are selected test level.
19.1.2 Performance Criterion
Performance criterion C at the test level 30%, 60%
Performance criterion B at the test level 0%.
Performance criterion B at the test level 0%.
Report No. JSH006030124-001
Page 70 of 81
19.2 Block diagram of test setup
Best EMC
EUT
GRP
19.3 Test Setup and Test Procedure
19.3.1 Test setup
The EUT was placed on an insulating support of 0.8m height, standing on a ground reference
plane, and arranged and connected to satisfy its functional requirement
The test was performed with the EUT connected to the test generator with the shortest power
supply cable as specified by the EUT manufacturer.
19.3.1.1 Photo for test set-up
none
The test was performed with the EUT connected to the test generator with the shortest power
supply cable as specified by the EUT manufacturer.
19.3.1.1 Photo for test set-up
none
19.3.2 Test Procedure
The EUT was tested for each selected combination of test level and duration with a sequence of
three dips/interruptions with intervals of 10 s minimum. Each representative mode of operation was
tested.
tested.
EUT is tested for voltage dips of 100%Ut, 0.5 period, 40%Ut,10 periods and 70%Ut,50 periods,
for
100%Ut, both the positive and negative polarity test was conducted.
Abrupt changes in supply voltage was occur at zero crossings of the voltage and at additional
Abrupt changes in supply voltage was occur at zero crossings of the voltage and at additional
angles
considered critical by product committees or individual product specifications preferably selected
from 45
from 45
°,90°, 135°, 180°, 225°, 270°,315°.
19.4 Test Protocol
Temperature
:
23
°C
Relative Humidity
:
34%
Report No. JSH006030124-001
Page 71 of 81
Test no.
Test level
Voltage
level in % of
rated U
Duration in
periods of
rated fq
Pass/
Fail
Comment
1 30% 70
25
Pass
2 100%
0 0.5
Pass
3 100%
0 250
Pass
19.5 Additions, Deviations and Exclusions from Standards
None