Harman Kardon HS 300 (serv.man3) EMC - CB Certificate ▷ View online
Report No. JSH006030124-001
Page 60 of 81
15.2 Block Diagram of Test Setup
Best EMC
EUT
5.2 .1Test
Ta
lane
en the EUT and any other of the metallic surface except the GRP is
reater than 0.5m.
e plane to insure the distance between the
oupling device and the EUT were 1m or less.
its functional requirement and supplied by
The coupling-decoupling network (Best EMC).
Floor Standing EUT
anding on the ground reference
lane 2.6m by 1.8m, made by aluminium 0.5mm thick.
en the EUT and any other of the metallic surface except the GRP is
reater than 0.5m.
e plane to insure the distance between the
oupling device and the EUT were 1m or less.
its functional requirement and supplied by
The coupling-decoupling network (Best EMC).
Setup and Test Procedure
ble top EUT
the ground reference
2.6m by 1.8m in size, made by aluminium 0.5mm thick.
GRP
1
The EUT was placed on a 0.8m high wooded table, standing on
p
The distance betwe
g
The main lead excess than 1m is gathered into a flat coil with a 0.4m diameter and situated
at a distance of 0.1m above the ground referenc
c
The EUT was arranged and connected to satisfy
p
The distance betwe
g
The main lead excess than 1m is gathered into a flat coil with a 0.4m diameter and situated
at a distance of 0.1m above the ground referenc
c
The EUT was arranged and connected to satisfy
The EUT was placed on a 0.1m high wooden support, st
p
The distance betwe
g
The main lead excess than 1m is gathered into a flat coil with a 0.4m diameter and situated
at a distance of 0.1m above the ground referenc
c
The EUT was arranged and connected to satisfy
p
The distance betwe
g
The main lead excess than 1m is gathered into a flat coil with a 0.4m diameter and situated
at a distance of 0.1m above the ground referenc
c
The EUT was arranged and connected to satisfy
Report No. JSH006030124-001
Page 61 of 81
15.2.2 Photo for test set-up
none
15.3 Test Protocol
Temperature :
23
°C
Relative Humidity:
34%
Test No.
#
Level
[kV]
Polarity
+/-
Line for test
Pass/
Fail
Comment
1 1 +/- L P
2 1 +/- N P
3 1 +/-
PE
NA
4 1 +/-
L-N
P
5 1 +/-
L-PE
NA
6 1 +/-
N-PE
NA
7 1 +/-
L,N.PE
NA
8 0.5 +/- DC -
9 0.5 +/- I/O -
15.4 Additions, Deviations and Exclusions from Standards
None.
Report No. JSH006030124-001
Page 62 of 81
16. Electromagnetic field susceptibility
Test result
Pass
16.1 Severity Level and Performance Criterion
16.1.1 Test level
Level
Test field strength V/m
1
1
2
3
3
10
X
Special
Note: 1. X is an open test level, this level may be given in the product specification.
2. The gray row is the selected test level.
16.1.2 Performance Criterion
Performance criterion A
Report No. JSH006030124-001
Page 63 of 81
16.2 Block diagram of test setup
Power
Antenn
a mask
a mask
Table
amplifier
Signal
EUT
Field
Optical
Filte
Field probe
16.3 Test Setup and Test Procedure
16.3.1 Test setup
The test was conducted in an anechoic chamber which is 7m in length, 5m in width and 3m in
height to maintain a uniform field of sufficient dimensions with respect to the EUT, and also in
order to comply with various national and international laws prohibiting interference to radio
communications.
order to comply with various national and international laws prohibiting interference to radio
communications.
For the table top EUT, the equipment is placed in the test facility on a non-conducting table
0.8m high.
For the floor standing EUT, the equipment is placed in the test facility on a non-conducting
support 0.1m high.
The EUT was placed on the uniform calibrated plane which is 3V/m EM field.
Unshielded parallel wire was used during the test.
Wire is left exposed to the electromagnetic field for a distance of 1m form the EUT.