EMC - CB Certificate
Brand
Device
Audio
File
hs-300-sm3.pdf
Date

Harman Kardon HS 300 (serv.man3) EMC - CB Certificate ▷ View online

 
 
Report No. JSH006030124-001 
Page 44 of 81  
 
9. Immunity requirements at loudspeaker and headphone output connector 
(S2a) 
9.1 Test result 
 
           Pass               Fail  
             Not Applicable 
9.2 Operating environment 
Temperature:                         20
°C   Relative Humidity:              45 %  
9.3 Test set-up 
 
The wanted test signal is supplied by generators G1,G2,G3 and G4, via the respective connections A or 
V or S or T and the unwanted signal is supplied by generator G5. Network RCi matches the RF 
disturbance source to the input impedance of the relevant audio terminal and a similar network Rco is 
used to match the output terminals. Mains stop filter MSF is used to inject the unwanted signal at the 
mains terminal and acts as a stop filter for unwanted signals from the mains network. 
 The equipment under test is placed 0.1m above the centre of a metal ground plane of dimensions 2m 
by 1m. The mains lead shall be bundled to a length less than 0.3m and connected in the shortest 
possible way to the mains stop filter MSF. The connection between the metal ground plane and the 
shield of the RF cable at the audio input and output terminals shall be as short as possible.  
The connecting cables are of the 50
Ω coaxial type. 
The unwanted signal was amplitude modulated with 1kHz at 80% depth, supplied by generator G5. 
 
9.3.1  Photo For test Set-up 
   none. 
 
9.4 Performance Criterion : A 
9.5 Figure for test set up  
 
 
 
 
Report No. JSH006030124-001 
Page 45 of 81  
 
 
Report No. JSH006030124-001 
Page 46 of 81  
9.6 Test protocol 
 
Inject Frequency(MHz) 
Sound(dBuV) 
Picture(dBuV) 
Headphone 
0.15  - 150.00 
“*” means margin > 6 dB 
 
10. Immunity requirements for audio input and output connectors (excluding loudspeaker and 
headphone) (S2a) 
10.1 Test result 
 
           Pass               Fail              Not Applicable 
10.2 Operating environment 
 
Temperature:                           20
°C  
Relative Humidity:                  45 %  
10.3 Test set-up 
The wanted test signal is supplied by generators G1,G2,G3 and G4, via the respective connections A or 
V or S or T and the unwanted signal is supplied by generator G5. Network RCi matches the RF 
disturbance source to the input impedance of the relevant audio terminal and a similar network Rco is 
used to match the output terminals. Mains stop filter MSF is used to inject the unwanted signal at the 
mains terminal and acts as a stop filter for unwanted signals from the mains network. 
 The equipment under test is placed 0.1m above the centre of a metal ground plane of dimensions 2m 
by 1m. The mains lead shall be bundled to a length less than 0.3m and connected in the shortest 
possible way to the mains stop filter MSF. The connection between the metal ground plane and the 
shield of the RF cable at the audio input and output terminals shall be as short as possible.  
The connecting cables are of the 50
Ω coaxial types. 
The unwanted signal was amplitude modulated with 1kHz at 80% depth, supplied by generator G5. 
 
10.3.1  Photo For test Set-up 
    none 
 
10.4 Performance Criterion : A  
 
10.5 Figure for test set up  
 
 
Report No. JSH006030124-001 
Page 47 of 81  
Page of 82